Abstract: The use of indirect, all-ceramic restorations has grown in popularity among dentists. Studies have demonstrated that for indirect ceramic restorations to be effective over time, cement and ceramic must be bonded in a stable manner. Chemical, mechanical, and laser irradiation are among the methods used to precondition ceramic surfaces in order to increase bond strength.The objective of the study: This study was performed to investigate the roughness values and surface topography of lithium disilicate glass-ceramic treated with conventional methods and different Er,Cr:YSGG, and fractional CO2 laser conditioning parameters.Material and methods: Sixty samples of lithium disilicate glass-ceramic were divided as follows: 1- (n = 10) untreated; 2- (n = 10) Hydrofluoric acid etched; 3- (n = 10) conditioned by Er,Cr: YSGG laser at (7 W, 25 Hz, 50/50% Water/Air, pulse duration 60 us, irradiation time 2 min); 4- (n = 10) conditioned by Er,Cr:YSGG laser at (5 W, 25 Hz, 50/50% Water/Air, pulse duration 60 us, irradiation time 2 min); 5- (n = 10) conditioned by fractional CO2 laser at (power 8 W, pulse duration 10 ms); 6- (n = 10) conditioned by fractional CO2 laser at (power 6 W, pulse duration 10 ms). Then evaluated by: Profilometer, and scanning electron microscopy.Results: The highest roughness values were found in CO2 laser power 8 W treated samples, followed by Er,Cr:YSGG laser power 7W treated samples. The hydrofluoric acid-etched samples showed roughness values comparable to those of CO2 laser-irradiated samples with a power of 6 W. The untreated sample showed the smoothest surface with the lowest roughness value.Conclusion: The application of Er,Cr:YSGG, fractional CO2 lasers enhances the surface roughness of lithium disilicate samples positively, showing the promised results of using these parameters in bonding procedures.
The primary objective of this study was to identify the mechanisms for the development and propagation of longitudinal cracks that initiate at the surface of composite pavement. In this study the finite element program ANSYS version (5.4) was used and the model worked out using this program has the ability to analyze a composite pavement structure of different layer properties. Also, the aim of this study was modeling and analyzing of the composite pavement structure with the physical presence of crack induced in concrete underlying layer. The results obtained indicates that increasing the thickness of the asphalt layer tends to decrease the stress intensity factor, which may be attributed to the rapidly decrease of horizontal tensile st
... Show MoreBackground: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group,
... Show MorePorous silicon (P-Si) has been produced in this work by photoelectrochemical (PEC) etching process. The irradiation has been achieved using diode laser of (2 W) power and 810 nm wavelength. The influence of various irradiation times on the properties of P-Si material such as P-Si layer thickness, surface aspect, pore diameter and the thickness of walls between pores as well as porosity and etching rate was investigated by depending on the scanning electron micrograph (SEM) technique and gravimetric measurements.
In this work Polyynes was synthesized by pulse laser ablation of graphite target in ethanol solution. UV-Visible Spectrophotometer, Fourier Transform Infrared Spectroscopy (FTIR) and Transmission electron microscopy (TEM) were used to study the optical absorption, chemical bonding, particle size and the morphology. UV absorption peaks coincide with the electronic transitions corresponding to linear hydrogen – capped polyyne (Cn+1H2), the absorption peaks intensity increased when the polyynes were produced at different laser energies and the formation rats of polyynes increased with the increasing of laser pulse number. The FTIR absorption peak at 2368.4 cm-1, 1640.0 cm-1 and 1276.
... Show MoreLiposomal amphotericin B (Amph B) has been used effectively to treat leishmaniosis, in spite of its high toxicity appeared in some patients. In our study, Amph B was administered in Leishmania donovani that infected BALB/c male mice using different concentrations to evaluate its efficacy challenge against infection as well as its effect in modulating immunity of the host. We observed that low doses with short duration of Amph B as a therapy regime significantly enhanced the induction of Th1 cytokine (INF-γ), but suppressed Th2 cytokine (IL-10) production. Groups of mice infected with L. donovani and treated with Amph B showed clearly increasing in INF-γ level and reduction in IL-10 level in concentration (3, 4, 5 mg/ml/kg) with best resul
... Show MoreBackground: Assessment of function of the right side of the heart in cases of left ventricular dysfunction has been widely studied but the sensitive and specific echocardiographic parameter to be tested is still a matter of controversy. Right ventricular function is related to left ventricular function by ventricular independence so function of both should be assessed carefully. The objective of this study was to evaluate the effects of left ventricular systolic dysfunction on right ventricular systolic and diastolic functions and pulmonary pressure using conventional and tissue Doppler echocardiography. Patients and Methods: Sixty patients (39 males and 21 females) with heart failure due to left ventricular systolic dysfunction
... Show MoreElectrical Discharge Machining (EDM) is a non-traditional cutting technique for metals removing which is relied upon the basic fact that negligible tool force is produced during the machining process. Also, electrical discharge machining is used in manufacturing very hard materials that are electrically conductive. Regarding the electrical discharge machining procedure, the most significant factor of the cutting parameter is the surface roughness (Ra). Conventional try and error method is time consuming as well as high cost. The purpose of the present research is to develop a mathematical model using response graph modeling (RGM). The impact of various parameters such as (current, pulsation on time and pulsation off time) are studied on
... Show MoreDespite the broad approbation of additive manufacturing technologies over diverse industries, printed parts’ performance, quality, and related build time are still greatly influenced by printing parameters. These parameters majorly affect mechanical strength, surface finish, dimensional accuracy, and overall production time of the printed part. Customized 3D printing layer thickness, speed, and acceleration are crucial parameters that affect the speedy printing process and final product quality. The current work considers layer thickness in addition to speed and high acceleration values effect on the surface quality, surface roughness and productivity time of 3D printed Polylactic Acid (PLA). The experimental methodology implemented withi
... Show MoreBackground: One effective second-generation triptan for migraine attacks is sumatriptan. Following oral use, it has a 40% restricted bioavailability because of the first-pass metabolism. Aim: To develop the best intranasal Solusomes formula as a substitute that delivers into the brain directly, improving its bioavailability, and removing the first-pass outcome was the aim of this effort. Methodology: We developed solute formulations based on the Box-Behnken design and subsequently produced them via thin-film hydration. The quality by design technique was used to establish a correlation between the formulation parameters (Soluplus® and phosphatidylcholine (PC) concentrations) and signif¬icant quality powers (entrapment efficiency (
... Show More