Abstract: The use of indirect, all-ceramic restorations has grown in popularity among dentists. Studies have demonstrated that for indirect ceramic restorations to be effective over time, cement and ceramic must be bonded in a stable manner. Chemical, mechanical, and laser irradiation are among the methods used to precondition ceramic surfaces in order to increase bond strength.The objective of the study: This study was performed to investigate the roughness values and surface topography of lithium disilicate glass-ceramic treated with conventional methods and different Er,Cr:YSGG, and fractional CO2 laser conditioning parameters.Material and methods: Sixty samples of lithium disilicate glass-ceramic were divided as follows: 1- (n = 10) untreated; 2- (n = 10) Hydrofluoric acid etched; 3- (n = 10) conditioned by Er,Cr: YSGG laser at (7 W, 25 Hz, 50/50% Water/Air, pulse duration 60 us, irradiation time 2 min); 4- (n = 10) conditioned by Er,Cr:YSGG laser at (5 W, 25 Hz, 50/50% Water/Air, pulse duration 60 us, irradiation time 2 min); 5- (n = 10) conditioned by fractional CO2 laser at (power 8 W, pulse duration 10 ms); 6- (n = 10) conditioned by fractional CO2 laser at (power 6 W, pulse duration 10 ms). Then evaluated by: Profilometer, and scanning electron microscopy.Results: The highest roughness values were found in CO2 laser power 8 W treated samples, followed by Er,Cr:YSGG laser power 7W treated samples. The hydrofluoric acid-etched samples showed roughness values comparable to those of CO2 laser-irradiated samples with a power of 6 W. The untreated sample showed the smoothest surface with the lowest roughness value.Conclusion: The application of Er,Cr:YSGG, fractional CO2 lasers enhances the surface roughness of lithium disilicate samples positively, showing the promised results of using these parameters in bonding procedures.
Background:The demand for esthetic orthodontic appliances is increasing so that the esthetic orthodontic archwires were introduced. This in vitro study was designed to evaluate the surface roughness offiber-reinforced polymer composite (FRPC) archwires compared to coated nickel-titanium (NiTi) archwires immersed in artificial saliva. Materials and Methods:Three types of esthetic orthodontic archwires were used: FRPC (Dentaurum), Teflon coated NiTi (Dentaurum) and epoxy coated NiTi (Orthotechnology). They were round (0.018 inch) in cross section and cut into pieces of 15 mm in length.Forty pieces from each type were divided into four groups; one group was left at a dry condition and the other three groups were immersed in artificial saliva (
... Show MoreEfficacy of Several Forms of Storage Medium on Avulsed Teeth's Enamel Surface Roughness (An in Vitro Study), Rawaa Sadiq Obeid1*, Muna Saleem Khalaf2
Thin films of (CdO)x (CuO)1-x (where x = 0.0, 0.2, 0.3, 0.4 and 0.5) were prepared by the pulsed laser deposition. The CuO addition caused an increase in diffraction peaks intensity at (111) and a decrease in diffraction peaks intensity at (200). As CuO content increases, the band gap increases to a maximum of 3.51 eV, maximum resistivity of 8.251x 104 Ω.cm with mobility of 199.5 cm2 / V.s, when x= 0.5. The results show that the conductivity is ntype when x value was changed in the range (0 to 0.4) but further addition of CuO converted the samples to p-type.
Q-switch Nd: YAG laser of wavelengths 235nm and 1,460nm with energy in the range 0.2 J to 1J and 1Hz repetition rate was employed to synthesis Ag/Au (core/shell) nanoparticles (NPs) using pulse laser ablation in water. In this synthesis, initially the silver nano-colloid prepared via ablation target, this ablation related to Au target at various energies to creat Ag/Au NPs. Surface Plasmon Resonance (SPR), surface morphology and average particle size identified employing: UV-visible spectrophotometer, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The absorbance spectra of Ag NPs and Ag/Au NPs showed sharp and single peaks around 400nm and 410nm, respec