Preferred Language
Articles
/
ijl-398
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-beam computed tomography (CBCT). Results: Cone beam computed tomography (CBCT) analysis found statistically significant quotient differences between the study groups were discovered. (P = <0.001) had a better degree of bone integration than the control group after 3 months of observation of different powers the best power effect on bone density around the implant from group 1 is 50 mW while the best power in bone density around the implant from group 2 is 4 W Conclusion: Effective osteogenesis promotion by photobiomodulation is possible; the bone healing process was accelerated around implants by different powers of 650nm and 976nm of the laser's photobiomodulation action.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Study of Laser Propagation Parameters in the Underdense Plasma Region Using a Two Dimensional Simulation Code
...Show More Authors

The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for  = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.

View Publication Preview PDF
Publication Date
Sat Sep 19 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of systemic administration of Simvastatin on dental implant stability: A random clinical study
...Show More Authors

Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 1

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 04 2019
Journal Name
American Association Of Pharmaceutical Scientists
Recent advances in polymeric implants
...Show More Authors

Implantable drug delivery systems, such as drug pumps and polymeric drug depots, have emerged as means of providing predetermined drug release profiles at the desired site of action. While initial implants aimed at providing an enduring drug supply, developments in polymer chemistry and pharmaceutical technology and the growing need for refined drug delivery patterns have prompted the design of sophisticated drug delivery implants such as on-demand drug-eluting implants and personalized 3D printed implants. The types of cargo loaded into these implants range from small drug molecules to hormones and even therapeutic cells. This review will shed light upon recent advances in materials and composites used for polymeric implant fabrication, hi

... Show More
View Publication
Publication Date
Tue Sep 03 2019
Journal Name
Aaps Pharmscitech
Recent Advances in Polymeric Implants
...Show More Authors

View Publication
Scopus (31)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Fri Nov 02 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Inducing the Health Promotion Model for Nursing Practice: Qualitative Study
...Show More Authors

Objective: To generate a model that conceptualizes the phenomenon of health promotion and its related factors.
Methodology: A grounded theory methodology is used as qualitative method to explore the health promotion as
phenomenon of interest and its other related factors from the perspectives of specialists in this field. The study is
carried out from January 2002 through September 2004. A sample of (20) specialists in health sciences are
selected and interviewed as experts in the area of health promotion. The investigators conducted intensive and
structured interviews with the specialists to collect the data. These interviews were transcribed verbatim,
analyzed and interpreted.
Results: Findings of the study indicat

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Comparing Bayes Estimators With others , for scale parameter and Reliability function of two parameters Frechet distribution
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 09 2022
Journal Name
Journal Of Craniofacial Surgery
The Use of Osseodensification for Ridge Expansion and Dental Implant Placement in Narrow Alveolar Ridges: A Prospective Observational Clinical Study
...Show More Authors

The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference b

... Show More
View Publication
Scopus (11)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2026
Journal Name
Journal Of The Society For Cardiovascular Angiography &amp; Interventions
A Novel Strategy to Promote Equity and Access in Interventional Cardiology: Early Insights From the 2024-2025 ACC Clinical Trial Research Cohort
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
The International Journal Of Oral &amp; Maxillofacial Implants
Early Failure Rate and Associated Risk Factors for Dental Implants Placed With and Without Maxillary Sinus Augmentation: A Retrospective Study
...Show More Authors

View Publication
Scopus (26)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of SOLO and Sodium Hypochlorite Disinfectant on Some Properties of Different Types of Dental Stone
...Show More Authors

Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60 test block w

... Show More
View Publication
Crossref (2)
Crossref