Preferred Language
Articles
/
ijl-387
The Effect of Dual Diode Laser: (810,980) nm in Acceleration of Orthodontic Tooth Movement A Case Report
...Show More Authors

Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bilateral extraction of the upper first premolar teeth on both sides and distalization of the anterior segment to close the created space. For an experimental investigation, a patient was chosen at random and given right-side radiation using a dual diode laser (810,980 nm wavelength, 100 mW output power). Results: The tooth movement was measured over a period of 15 weeks; the first three orthodontic activations on the study side included scheduled laser treatment (the first month, laser-assisted treatment on days (0,3,7, and 14), the following two months, on days (0 and 14) from the day of orthodontic activation, and another 3 months of follow-up only); it was observed that orthodontic tooth movement was significantly higher in the study side than in the control side, as measured clinically using a digital vernier. We also noticed a considerable decrease in pain levels following a visual analog test. Conclusion: LLLT might clinically considerably speed orthodontic tooth movement and greatly lessen discomfort using the parameter settings employed in this investigation.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Corrosion Pits in Esthetic Coated Stainless Steel Orthodontic Archwires in Dry and Wet Environment at Different Intervals (An In Vitro Study)
...Show More Authors

Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Effect of Oscillatory Motion in Enhancing the Natural Convection Heat Transfer from a Vertical Channel
...Show More Authors

This paper reports an experimental study regarding the influence of vertical oscillations on the natural convection heat transfer from a vertical channel. An experimental set-up was constructed and calibrated; the vertical channel was tested in atmosphere at 25o
C. The channel-to-ambient temperature difference was varied with the power supply to the electrical heater ranging between
15W to 70W divided into five levels. Data sets were measured under different operating condition from a test rig under six vibrating velocities (VVs) levels ranging from (5-30 m/s) in addition to the stationary state. The results show that the maximum heat transfer enhancement factor (E) occurs at Rayleigh number (Ra=2.328×103 ) and vibrational Reynol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Journal Of The College Of Languages (jcl)
A Contrastive- Acoustic Study of Jacqueline Kennedy and the Actress Natalie Portman’s Voice Qualities in the Film” Jacki”.
...Show More Authors

As performers in a social world, we communicate with other people by sharing information on many different levels. Each utterance includes linguistic information and conveys much information about the speaker’s identity. Variation in voice quality indexes information about the speaker and marks the speaker’s identity as a unique individual. The present study aims to validate the belief that each individual has an inalienable voice print that can’t be imitated. The study verifies that, even the more similar personality between two individuals, or the close position in society the variance is voice quality. The acoustic analysis is performed via analysing the acoustic parameters namely: the fundamental frequency, amplitude, inten

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of PH Variation on the Particle Size of Sio2 Thin Films
...Show More Authors

In this paper, SiO2 nanoparticles thin films were synthesised at different PH values of solution by sol gel method at fixed temperature (25oC) and molar ratio (R =H2O/precursor) of (Tetra Ethyl Ortho Silicate) TEOS as precursor at (R=1). The structure and optical properties of the thin films have been investigated. All thin films were tested by using X-RAY diffraction. All X-RAY spectrum can be indexed as monoclinic structure with strong crystalline (110) plane. The morphological properties of the prepared films were studied by SEM. The results indicate that all films are in nano scale and the particle size around (19-62) nm .The size of silica particles increases with increasing PH value of solution where both the rate of hydrolysis and

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Intraoral Repair of Dental Ceramics Using Er,Cr:YSGG Laser: Review
...Show More Authors

Introduction: All-ceramic crowns are widely used in prosthodontics and cosmetic dentistry due to their good esthetic and proper physical properties. Chipping of ceramic is one of the most common post-insertion complications, that can be fixed either extraoral or intraorally. The latter is time time-effective alternative, less traumatic, and low-cost. A newer objective method of laser is a surface modification of ceramics to increase surface roughness. The aim of this study is to provide a review of Er,Cr;YSGG (2960nm) in intraoral repair and shear bond strength (SBS). Method: A thorough search considering Google Scholar and PubMed published data and ten articles found wh

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Feb 21 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Role of Re-engineering Business Processes in Continuous Improvement: Exploratory Statement of The Views of a Sample of The Faculties in The Law, Administration and Economy- University of Baghdad
...Show More Authors

The present study aimed to investigate the effect of re-operations engineering business in continuous improvement, as the rapid development of service activities generally private and the great diversity in the goals of its operations and programs of the university and the service has led to the increasing importance of re-operations engineering business as well as continuous improvement so began to study the relationship between the re engineering and continuous improvement of university service, and applied study on a sample of professors from the faculties of administration, economics and law. Find and reach to several conclusions, notably that the preparation of the teaching staff training sessions on how to use modern teaching

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Journal Of Economics And Administrative Sciences
The use of the Principal components and Partial least squares methods to estimate the parameters of the logistic regression model in the case of linear multiplication problem
...Show More Authors

Abstract

  The logistic regression model is one of the nonlinear models that aims at obtaining highly efficient capabilities, It also the researcher an idea of the effect of the explanatory variable on the binary response variable.                                                                                  &nb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
A three-stage blumlein-circuit to generate transversely excited atmospheric nitrogen laser by using three spark gaps
...Show More Authors

In this research constructed N2 laser system by use developed method of electric discharge. In this method used four step of electric discharge by using four capacitors, three spark gaps, high tension power supply varying in range from 12kV to 24 kV and three resistors, this method called three stage blumlein circuit. The breakdown time delay of these parallel spark gaps cement strong ultraviolet preionization in the laser channel, thus the result of these amendments the laser output is many doubled and is more increasing than that obtained using the one and two stage blumlein circuits. This system has been designed and operated to give pulse laser with wavelength at 337.1 nm. This laser system can operate without mirrors and optical res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Nanosecond laser pulses for aluminum and copper drilling
...Show More Authors

Nd:YAG laser pulses of 9 nanosecond pulse duration and operating wavelength at 1.06 μm, were utilized to drill high thermal conductivity and high reflectivity aluminum and copper foils. The results showed a dependence of drilled holes characteristics on laser power density and the number of laser pulses used. Drilled depth of 74 ϻm was obtained in aluminum at 11.036×108 W/cm2 of laser power density. Due to its higher melting point, copper required higher laser power density and/or larger number of laser pulses to melt, and a maximum depth of 25 μm was reached at 13.46×108 W/cm2 using single laser pulse.

View Publication Preview PDF
Crossref
Publication Date
Mon Sep 30 2019
Journal Name
College Of Islamic Sciences
What Bukhari shortened to a bug in its attribution: (Applied study in the correct mosque)
...Show More Authors

This study aims to show some of Imam Al-Bukhari's criticism of the Hadith from the Metn side, and part of his methodology in dealing with the correct hadiths that are tainted by a bug. This research focuses on what Imam Al-Bukhari summarized in his Sahih illusion of the narrator in his attribution, or uniqueness of the narrator, or to suggest a novel. We find that Bukhari sometimes abbreviates the hadeeth, and does not bring it out completely in his Sahih. He is satisfied with the abbreviated position but has done so because of a bug in it. The Bukhari usually does not declare his intention but knows this through tracking, inspection, and research of the correct hadiths.

View Publication Preview PDF