Preferred Language
Articles
/
ijl-351
PDF Angular Laser Cleaning of Aluminum Al-4004 with Different Spot Sizes
...Show More Authors

Abstract: When it comes to applications in welding, cutting, and surface engineering, the utilization of high-power fiber-delivered beams from solid-state lasers offers several benefits. This paper addresses the issue of cleaning the surface of the samples with different spot sizes (50, 100 and 200) (industrial ytterbium fiber laser) to prepared it to be welded. Angular laser cleaning with incident angles (5, 10, 15, 20, 25, 30) ° with different powers (3, 5, 7, 10) W and hatch distance 0.001 was use for implemented.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study the effect of the different doses from the laser on Staphylococcus aureus Bacteria growth in vitro
...Show More Authors

Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archives
Effect of alternate water quality irrigation on pore sizes distribution during drainage in clay loam texture soil
...Show More Authors

Scopus (2)
Scopus
Publication Date
Tue Nov 14 2006
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
[PDF] من iasj.net Synthesis and Characterization of Some New Transition Metal Complexes of Amino
...Show More Authors

الوصف New complexes of Cu (ll), Ni (II)„Co (II), and Zn (ll) with 2-amino-5-p-Flouro Phenyl 1, 3, 4-Thiadiazole have been synthesized. The products were isolated, studied and characterized by physical measurements, ie,(FT-IR)„UV-Vis and the melting points were determined. The new Schiff base (L) has been used to prepare some complexes. The prepared complexes were identified and their structural geometry were suggested

Publication Date
Tue Mar 05 2024
Journal Name
Scientific Reports
Mesoporous Ag@WO3 core–shell, an investigation at different concentrated environment employing laser ablation in liquid
...Show More Authors
Abstract<p>In this study, silver-tungsten oxide core–shell nanoparticles (Ag–WO<sub>3</sub> NPs) were synthesized by pulsed laser ablation in liquid employing a (1.06 µm) Q-switched Nd:YAG laser, at different Ag colloidal concentration environment (different core concentration). The produced Ag–WO<sub>3</sub> core–shell NPs were subjected to characterization using UV–visible spectrophotometry, X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive spectroscopy, electrical analysis, and photoluminescence PL. The UV–visible spectra exhibited distinct absorption peaks at around 200 and 405 nm, which attributed to the occurrence of surface Plasmon reson</p> ... Show More
View Publication
Scopus (15)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Tue Dec 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Interventional Program on Nurses Practices regarding Removing and Cleaning Burn Dead Tissue
...Show More Authors

Abstract

Objective(s): The study aims to measure the effectiveness of the program on removing dead tissue for burn patients by testing the nurses before the program in addition to testing them again after implementing the educational program.

Methodology: The study is quantitative in nature (one experimental) and will employ pre- and post-testing techniques between October 17, 2020 and March 20, 2022. A non-probability (purposive) sample of 24 nurses working in the Azadi Teaching Hospital's Burns and Plastic Surgery Center was chosen. The experimental survey of nursing practice, a literature review, scientific records, and previous research were all taken into considerat

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Anodic Polarization of Anodized Aluminum Alloy 5052
...Show More Authors

Aluminum alloy 5052 had been anodized by sulfuric acid as an electrolyte under constant voltage and the anodic oxide film produce will be testing by potentiostatic anodic polarization .Two variables, which were considered as important variables, were studied. These variables are anodizing time 15,30 min. and sealing time 10,20 min., and the test by potentiostatic anodic polarization through electro chemical polarization measurements in solutions of 1N na2so4 ( PH= 1 ). The results are discussed in light of the rate of ionic current flow through the coating during anodic polarization measurements.

View Publication Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
The effect of Aluminum Oxide, Iron Oxide on the thermal conductivity of (Epoxy-Aluminum Oxide, Epoxy-Iron Oxide) Composites
...Show More Authors

Thermal conductivity for epoxy composites filled with Al2O3 and Fe2O3 are
calculated, it found that increasing the weight ratio of Al2O3 and Fe2O3 lead to
increase in the values of thermal conductivity, but the epoxy composite filled with
Fe2O3, have values of thermal conductivity less than for epoxy composite filled with
Al2O3, for the same weight ratio. Also thermal conductivity calculated for epoxy
composites by contact to every two specimens (like sandwich) content same weight
ratio of alumina-oxide and ferrite-oxide, its found that the value of thermal
conductivity lays between the values of epoxy filled Al2O3 and of epoxy filled Fe2O3

View Publication Preview PDF
Publication Date
Tue Jul 14 2020
Journal Name
Materials Science Forum
The Cyclic Fatigue Behavior for 6061-T6 Al Alloy Shafts Processed by Laser Shock Peening
...Show More Authors

The optimal combination of aluminum quality, sufficient strength, high stress to weight ratio and clean finish make it a good choice in driveshafts fabrication. This study has been devoted to experimentally investigate the effect of applying laser shock peening (LSP) on the fatigue performance for 6061-T6 aluminum alloy rotary shafts. Q-switched pulsed Nd:YAG laser was used with operating parameters of 500 mJ and 600 mJ pulse energies, 12 ns pulse duration and 10 Hz pulse repetition rate. The LSP is applied at the waist of the prepared samples for the cyclic fatigue test. The results show that applying 500 mJ pulse energy yields a noticeable effect on enhancing the fatigue strength by increasing the required number of cycles to fracture the

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Experimental Study of Spatial Self-Phase Modulation (SSPM) Based on Laser Beam and Hybrid Functionalized Carbon Nanotubes/Silver Nanoparticles (F-Mwcnts/Ag-Nps) Acetone Suspensions
...Show More Authors

Focusing of Gaussian laser beam through nonlinear media can induce spatial self- phase modulation which forms a far field intensity pattern of concentric rings. The nonlinear refractive index change of material depends on the number of pattern rings. In this paper, a formation of tunable nonlinear refractive index change of hybrid functionalized carbon nanotubes/silver nanoparticles acetone suspensions (F-MWCNTs/Ag-NPs) at weight mixing ratio of 1:3 and volume fraction of 6x10-6 , 9x10-6 , and 18x10-6 using laser beam at wavelength of 473nm was investigated experimentally. The results showed that tunable nonlinear refractive indices were obtained and increasing of incident laser power density led to increase the nonlinear refractive inde

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF