Preferred Language
Articles
/
ijl-340
PDF Design Optical BPF Using Double Clad Fiber MZI for Free Space Optical Communication: Mohanad G. Khamees , Tahreer S. Mansour*
...Show More Authors

Abstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s sensing arm (double clad fiber) was etched using 40% Hydro-Fluoric (HF) acid to achieve three different fiber diameters, which are ( 84, 72, 54 ) µm with ( 5 ) cm length. The simulation programs Optiwave version 15 and Optigrating version 4.2.2 were used to simulate the setup and to acquire the readings for the three durations of etching (10, 20, and 30) min, and also for the case of no etching at all. The obtained results show that the simulated setup can be used efficiently to test which one of the etching cases has the highest effect on the performance of the overall system, specifically when it comes to spectrum bandwidth, signal amplitude, and received power.

 

The simulated design contains a MZI of 1546.74 n. meter of central reflection wavelength that is constructed from different types of optical fibers. The used Double Clad (DC) optical fiber diameter was reduced in 3 steps as if it was etched using Hydro-Fluoric (HF) acid to achieve three additional different diameters, which are (84, 72, 54) µ. meters in addition to the default 125 µ. meters.

 

The simulation programs (Optiwave and Optigrating) were used to simulate the setup and to acquire the readings for the three durations of etching (10, 20, and 30) min, and also for the case of no etching at all. The obtained results show that the simulated setup can be used efficiently to test which one of the etching cases has the highest effect on the performance of the overall system, specifically when it comes to spectrum bandwidth, signal amplitude, and received power.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Iraqi Journal Of Physics
Preparation of Polyvinyl Alcohol/ Tio2 Nano Fiber by Electrospinning
...Show More Authors

ِabstract:In this research we prepared nanofibers by electrospinning from poly (Vinyl Alcohol) /TiO2. The spectrum of the solution (Emission) was studied and found to be at 772 nm, several process parameters were such as concentration of TiO2 , and the effect of distance from nozzle tip to the grounded collector (gap distance). The result of the lower concentration of, the smaller the diameter of nanofiber is. Increasing the gap distance will affect nanofibers diameter.

Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Behavior of Geopolymer Concrete Reinforced by Sustainable Copper Fiber
...Show More Authors

View Publication
Crossref (6)
Crossref
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Histological and Biochemical Parameters Follow-up in Experimental rats Administrated dexamethasone and Treated with Green Synthesis Titanium Dioxide Nanoparticles Using (Camillia sciences) Extracts
...Show More Authors

In this study, Titanium Dioxide Nanoparticles were synthesized by an easy and eco-friendly technique (green synthesis) using green tea leaves (Camillia sinensis), Nanoparticles were analyzed using structural and optical analysis, the X-ray pattern showed that Titanium Dioxide NPs had a tetragonal structure with (Face Centered Tetragonal) FCT crystal structure, the UV-visible recorded an absorbance peak near 350 nm and calculated energy band gap was 3.5 eV, all measurements were proved the purity and Nano size of prepared Nanoparticles. Biochemical parameters evaluation also mentioned in this research, these analyzes showed that Titanium Dioxide nanoparticles in particular dose (50 mg/kg) have the ability to reduce blood glucose

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Oct 11 2023
Journal Name
Journal Of Educational And Psychological Researches
Teaching Problems Faced by Female Teachers of Students with Intellectual Disability in Special Education Programs and the Proposed Solutions for that from their point of view - a qualitative study
...Show More Authors

This study aims to identify the teaching problems that teachers of students with intellectual disabilities face, in addition to exploring the solutions suggested by them in order to overcome such problems or challenges. The researchers used a qualitative approach in order to understand the teachers' perceptions about these problems in a more in-depth way. The interview tools (in-depth and semi-structured interviews) were used to collect data from (3) female teachers from special education programs in the Asir region. The results revealed a number of themes including problems related to students, teachers and the teaching methods they use, curricula, school environment, and school administration. Moreover, the results indicated that famil

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Common fixed points and S-best coapproximation in 2-Banach spaces
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
...Show More Authors

In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having h

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Al-khwarizmi Engineering Journal
Comparative Transfer Learning Models for End-to-End Self-Driving Car
...Show More Authors

Self-driving automobiles are prominent in science and technology, which affect social and economic development. Deep learning (DL) is the most common area of study in artificial intelligence (AI). In recent years, deep learning-based solutions have been presented in the field of self-driving cars and have achieved outstanding results. Different studies investigated a variety of significant technologies for autonomous vehicles, including car navigation systems, path planning, environmental perception, as well as car control. End-to-end learning control directly converts sensory data into control commands in autonomous driving. This research aims to identify the most accurate pre-trained Deep Neural Network (DNN) for predicting the steerin

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jun 11 2002
Journal Name
Iraqi Journal Of Laser
Investigating the Effects of Carbon Dioxide Laser Fluence on Oral Soft Tissue
...Show More Authors

This study investigates the surgical and thermal effects on oral soft tissues produced by CO2 laser emitting at 10.6 micrometers with three different fluences 490.79, 1226.99 and 1840.4 J/cm2. These effects are specifically; incision depth, incision width and the tissue damage width and depth. The results showed that increasing the fluence and /or the number of beam passes increase the average depths of ablation. Moreover, increasing the fluence and the number of beam passes increase the adjacent tissue damage in width and depth. Surgeons using CO2 laser should avoid multiple pulses of the laser beam over the same area, to avoid unintentional tissue damage.

View Publication Preview PDF
Publication Date
Tue Dec 31 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans: Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans
...Show More Authors

Six isolates of A. pullulans were collected from many sources including Hibiscus sabdariffa (Roselle), old Roofs of houses and bathroom surface that referred as Ap ros1, Ap or2, 3, 4 and Ap bs5, 6 respectively, all these isolates were identified based on morphological characteristics and nutritional physiology profiles, all were able to utilize various carbon and nitrogen sources such as glucose, xylose, sucrose, maltose, ammonium sulfate, ammonium nitrate and ammonium chloride, also they showed positive test for starch and amylase, while α-cellulose, ethanol, and methanol were could not be ass

... Show More
View Publication Preview PDF
Publication Date
Mon May 25 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
Training for Anaerobic Differential Threshold Stand and its Impact on Lactic Acid Concentration and LDH Enzyme and VO2MaX and Cortisol Hormone for Free 400 m men-runners
...Show More Authors

The study aimed at designing a training program by using training for the anaerobic differential threshold stand and the effects of those trainings on the variables of (Concentration of Lactic Acid and LDH Enzyme, VO2 MaX and Cortisol Hormone). The Researchers used the experimental program with one-group style. Also, they used a sample with (8) men-players in a (free 400 m men-runners) and they used many instruments and procedures, most notably the training-program prepared for 10 weeks and for 3 training units weekly, (70-90 min) for each unit. They used the training intensity from 85-100% of the player's ability. After finishing the training program and doing some pre-tests and post-tests then statistically checking the results, the resea

... Show More
View Publication
Crossref