Abstract :H.pylori is an important cause of gastric duodenal disease, including gastric ulcers, Mucosa-associated lymphoid tissue (MALT), and gastric carcinoma. biosensors are becoming the most extensively studied discipline because the easy, rapid, low-cost, highly sensitive, and highly selective biosensors contribute to advances in next-generation medicines such as individualized medicine and ultrasensitive point-of-care detection of markers for diseases. Five of ten patients diagnosed with H.pylori ranging in age from 15–85 participated in this research. who [gastritis, duodenitis, duodenal ulcer (DU), and peptic ulcer (PU)] Suspected H.pylori colonies were identified by the presence of urease, catalase, oxidase activity, and PCR. All parameters are fixed: Laser power:40 mW, size of drops:25 μ, Turbidity:0.5. , Multi modes optical fiber, and Coreless optical fiber to construct optical biosensor (Multimode-Coreless-Multimode) optical fibers based on an inline Mach-Zehnder Interferometer. All samples had a sensitivity. Multimode-Coreless-Multimode optical Biosensor: is a rapid and sensitive method for the detection of H.pylori bacteria.
Type-1 diabetes is defined as destruction of pancreatic beta cell, virus and bacteria are some environmental factor for this disease. The study included 25 patients with type-1 diabetes mellitus aged between 8 – 25 years from Baghdad hospital and 20 healthy persons as control group. Anti-rubella IgG and IgM, anti-Chlamydia pneumonia IgG and IgM were measured by ELISA technique while anti-CMV antibody were measured by immunofluorescence technique. The aim of current study was to know the trigger factor for type-1 diabetes. There were significant differences (P<0.05) between studied groups according to parameters and the results lead to suggest that Chlamydia pneumonia, CMV and rubella virus may trigger type-1 diabetes mellitus in Iraqi pat
... Show MoreBackground: Periodontitis is an inflammatory disease that affects the supporting tissues of the teeth; Smoking is an important risk factor for periodontitis induces alveolar bone loss and cause an imbalance between bone resorption and bone deposition. The purpose of this study is to detect and compare the presence of incipient periodontitis among young smokers and non-smokers by measuring the distance between cement-enamel junction and alveolar crest (CEJ-Ac) using Cone Beam Computed Tomography (CBCT). Material and methods: The total sample composed of fifty two participants, thirty one smokers and twenty one non-smokers (age range 14-22 years). Periodontal parameters: plaque index (PLI), gingival index (GI) were recorded for all teeth exc
... Show MoreThe current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are absolute ethanol, 50% aqueous ethanol and water for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreA procedure for the mutual derivatization and determination of thymol and Dapsone was developed and validated in this study. Dapsone was used as the derivatizing agent for the determination of thymol, and thymol was used as the derivatizing agent for the determination of Dapsone. An optimization study was performed for the derivatization reaction; i.e., the diazonium coupling reaction. Linear regression calibration plots for thymol and Dapsone in the direct reaction were constructed at 460 nm, within the concentration range of 0.3-7 μg ml-1 for thymol and 0.3-4 μg ml-1 for Dapsone, with limits of detection 0.086 and 0.053 μg ml-1, respectively. Corresponding plots for the cloud point extraction of thymol and Dapsone were constructed
... Show MoreThis study presents a novel, custom‑built fluorescence detector for the precise determination of chloride and iodide ions based on their quenching effect on fluorescein. The detection system incorporates eight blue LEDs irradiation sources arranged at 0–90° angles relative to twin solar cell detectors connected. Two fluorescence quenching strategies were developed. The injected‑mixture mode (IMFQ) exhibited linear ranges of 0.00–1.00 mM for Cl⁻ and 0.00–1.25 mM for I⁻, with detection limits of 20 µM and 10 µmol L⁻¹, respectively. The continuous‑flow mode (CFFQ) demonstrated superior sensitivity with a dispersion factor of 1.33, wider linear ranges (0.1–6.0 m