Preferred Language
Articles
/
ijl-294
Influence of Fractional CO2 Laser Irradiation on Temperature Elevation and Bonding Strength of Resin Cement to the Zirconia Ceramic
...Show More Authors

Abstract: Objectives: To investigate the effect of temperature elevation on the bonding strength of resin cement to the zirconia ceramic using fractional CO2 laser. Background: Fractional CO2 laser is an effective surface treatment of zirconia ceramic, as it increases the bonding strength of zirconia to resin cement. Methods: Thirty sintered zirconia discs (10 mm diameter, 2 mm thickness) were prepared and divided to three groups (N=10) and five diffident pulse durations were used in each group (0.1, 0.5, 1, 5 and 10 ms). Group A was treated with 10 W power setting, group B with 20 W and group C with 30 W. During laser irradiation, temperature elevation measurement was recorded for each specimen. Luting cement was bonded to the treated zirconia surfaces and cured for 30 seconds. Shear bond strength was evaluated by a testing machine (universal) with bond failure mode determination. Results: The lowest temperature elevation measurement of the irradiated specimen which gave maximum shear bond strength was about 1.6±0.3 Ċ higher than ambient room temperature (27±0.2 ºC). Apparent micromechanical irregularities were seen in the treated samples and cracks formation with increased pulse duration and power setting were also observed. Conclusions: The temperature elevation is a vital factor in the surface roughness of zirconia ceramic with fractional CO2 laser irradiation and the lowest temperature elevation at best shear bond strength of zirconia ceramic to the resin cement is satisfied with the shorter pulse duration of 0.1 millisecond.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 30 2023
Journal Name
Baghdad Science Journal
A relationship study of coronavirus (COVID-19) infection, blood groups, and some related factors in Iraqi patients
...Show More Authors

Many studies of the relationship between COVID-19 and different factors have been conducted since the beginning of the corona pandemic. The relationship between COVID-19 and different biomarkers including ABO blood groups, D-dimer, Ferritin and CRP, was examined. Six hundred (600) patients, were included in this trial among them, 324 (56%) females and the rest 276 (46%) were males. The frequencies of blood types A, B, AB, and O were 25.33, 38.00, 31.33, and 5.33%, respectively, in the case group. Association analysis between the ABO blood group and D-dimer, Ferritin and CRP of COVID-19 patients indicated that there was a statistically significant difference for Ferritin (P≤0.01), but no-significant differences for both D-dimer and CRP.

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Thu Feb 24 2022
Journal Name
Journal Of Educational And Psychological Researches
Social Care for the Disabled students and its influence on the Scientific Level (University of Baghdad as example)
...Show More Authors

The enrollment of students in the university represents a new stage in their life that differ from the previous educational stages that student has previously established. It should be noted that students with special needs at the University of Baghdad are not large numbers. It appears that these students have an excel role in their colleges most often, That is, the handicap was not a barrier to their scientific progress, but rather an incentive for them to excel. The most important conclusion reached by the researcher is that the University of Baghdad had no role in caring for people with special needs and caring for them financially, socially, psychologically, healthily and economically, they need to pay attention to them and take care

... Show More
View Publication Preview PDF
Publication Date
Sat May 16 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Plasma Treatment on Shear Bond Strength of High Impact Acrylic Resin Denture Base Lined with Two Types of Soft Lining Materials after Immersion in Distilled Water and Denture Cleanser
...Show More Authors

Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 13 2023
Journal Name
Journal Of Survey In Fisheries Sciences
The Elevation of Serum Subfatin Levels in Patients with Double Diabetes
...Show More Authors

Background: Hybrid diabetes (or double diabetes, DD) occur when the patient which exhibits characteristics that combine type 1 diabetes (T1DM) and type 2 diabetes (T2DM). Formerly epidemiological studies found that quarter of people with T1D also had the metabolic syndrome. Subfatin, Also called cometin, it is a small (~27kDa) cytokine secreted by protein encoded by a gene called METRNL (simeler of meteorin). is much expressed in skin in the mucosal tissues and activated macrophages. Subfatin has also been described as a hormone that effected in some diseases such as metabolic diseases (including dyslipidemia), type 2 diabetes and obesity. Objectives: The current study objective is evaluating the subfatin in the blood serum of double diabet

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Incident Laser Power and Concentration Effects on the Fluorescence of DCM Dye in PMMA Polymer
...Show More Authors

Incident laser power and concentration effects on fluorescence emission from DCM dye in PMMA polymer have been investigated. Different concentrations of the dye were used. It was found that the fluorescence intensity increased with increasing of the concentration of the dye, with a red shift. In addition, it was found that the fluorescence intensity increased with the increase of the incident laser power I0.

View Publication Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
The Impact of Intellectual trends on the nature of the Economic Structure of Iraq
...Show More Authors

The Impact of Intellectual trends on the nature of the Economic Structure of Iraq

View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recor

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Doppler Phenomenon on the Speed of Blood Flow
...Show More Authors

This research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of  disease and morbidity  of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of

... Show More
View Publication Preview PDF