Preferred Language
Articles
/
ijl-240
Rejuvenation of Facial Skin Using Fractional Er: YAG Laser
...Show More Authors

Fractional Er: YAG laser resurfacing is increasingly used for treating rhytides and photo aged skin because of its favorable benefit‐risk ratio. The multi-stacking and variable pulse width technology opened a wide horizon of rejuvenation treatments using this type of laser. To evaluate the efficacy and safety of the use of fractional 2940 nm Er: YAG laser in facial skin rejuvenation. Twelve female patients with mean age 48.3 years and multiple degrees of aging signs and solar skin damages, were treated with 2 sessions, one month apart by fractional Er: YAG laser. Each session consisted of 2 steps, the first step employed the use of the multi stack ablative fractional mode and the fractional long pulsed non-ablative mode settings were used in the second step. The results were assessed 4-8weeks after the last session by using the wrinkles assessment scale improvement, the improvement in the degree of dyschromia and keratosis, the degree of patients' satisfaction and rate of complications. The mean improvement in Wrinkles assessment scale was very satisfying. The improvement in keratosis was good to excellent in 66.7% of patients compared to 33.3% of patients who were mildly to moderately improved. Dyschromia improvement, 50% of the patients had good to excellent results versus 50% who had mild to moderate improvement. 75% of patients were well satisfied, 16.6% were moderately satisfied and 8.3% were unsatisfied. Total incidence of complications was 16.6%, where 1 patient had herpes infection and a second patient had milia. The use of Er: YAG laser in fractional ablative and fractional long pulse non ablative modes for facial rejuvenation is an effective, safe, with short down time and low complication rate.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Effect of CO2 Laser Irradiation on the Topographic and Optical Properties of CdO Thin Films
...Show More Authors

     In this study, cadmium oxide (CdO) was deposited on glass bases by thermal chemical spraying technique at three concentrations (0.05, 0.1, 0.15) M and then was irradiated by CO2 laser with 10.6 μm wave length and 1W power. The results of the atomic force microscope AFM test showed that the surfaces of these CdO thin films were homogenous and that the laser irradiated effect resulted in decreasing the roughness of the surface as well as the heights of the granular peaks, indicating a greater uniformity and homogeneity of the surfaces. The optical properties were studied to determine laser effect. The results of optical tests of these thin films showed that the photoluminescence spectra and absorption s

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Cosmetic And Laser Therapy
Use of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata
...Show More Authors

View Publication
Scopus (51)
Crossref (56)
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Effect of thermal annealing and laser radiation on the optical properties of AgAlS2 thin films
...Show More Authors

Effect of the thermal annealing at 400oC for 2 hours and Argon laser radiation for half hour on the optical properties of AgAlS2 thin films, prepared on glass slides by chemical spray pyrolysis at 360oC with (0.18±0.05) μm thickness .The optical characteristics of the prepared thin films have been investigated by UV/Vis spectrophotometer in the wavelength range (300 – 1100)nm .The films have a direct allow electronic transition with optical energy (Eg) values decreased from (2.25) eV for untreated thin films to (2.10) eV for the annealed films and to (2.00) eV for the radiated films. The maximum value of the refractive index (n) for all thin films are given about (2.6). Also the extinction coefficient (K) and the real and imaginary d

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Study the Effect of thickness on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.

View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Influence of working pressure and lasing energy of Al plasma in laser-induced breakdown spectroscopy
...Show More Authors

Aluminum plasma was generated by the irradiation of the target
with Nd: YAG laser operated at a wavelength of 1064 nm. The
effect of laser power density and the working pressure on spectral
lines generating by laser ablation, were detected by using optical
spectroscopy. The electron density was measured using the Stark
broadening of aluminum lines and the electron temperature by
Boltzmann plot method it is one of the methods that are used. The
electron temperature Te, electron density ne, plasma frequency
and Debye length increased with increasing the laser peak
power. The electron temperature decrease with increasing gas
pressure.

View Publication Preview PDF
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma
...Show More Authors

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
The Effect of Fluorine and Hydrogen Concentrations on the Chain Reaction of HF Chemical Laser
...Show More Authors

A numerical investigation has been performed to examine the effect of fluorine concentration on the chain reaction mechanisms and parameters of hydrogen fluoride (HF) chemical laser. The practical difficulties associated with this type of lasers impose that an alternative route might be quite useful. Thus, particular attention was paid to develop a computer program to investigate various processes. The results of this computer simulation program proved their credibility when compared with the little published data. This computer program is called Reaction Rate Simulation Model (RRSM). An entirely new approach to emulate the reaction mechanisms has been followed. The effectiveness of reaction rates in the processes of HF lase

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Laser Shock Peening on the Fatigue Behavior and Mechanical Properties of Composite Materials
...Show More Authors

In this study, Laser Shock Peening (LSP) effect on the polymeric composite materials has been investigated experimentally. Polymeric composite materials are widely used because they are easy to fabricate and have many attractive features. Unsaturated polyester resin as a matrix was selected and Aluminum powder with micro particles as a reinforcement material was used with different volume fraction (2.5%, 5% and 7.5%). Hand lay-up process was used for preparation the composites. Fatigue test with constant amplitude with stress ratio (R =-1) was carried out before and after LSP process with two levels of energy (1Joule and 2Joule). The result showed an increase in the endurance strength of 25.448% at 7.5% volume fraction when peened is 1J

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Analysis of inflammatory cells in osseointegration of CpTi implant radiated by low level laser therapy
...Show More Authors

Background: Dental implants provide a unique treatment modality for the replacement of a lost dentition .This is accomplished by the insertion of relatively an inert material (a biomaterial) into the soft and hard tissue of the jaws, there by providing support and retention for dental prostheses. Low level laser therapy (LLLT) is an effective tool used to prompt bone repair and remodeling, this has referred to the biostimulation effect of LLLT. The Aim of this study was to evaluate the effects of inflammatory cells on osseointegration of CpTi implant irradiated by low level laser. Materials and Methods: thirty two adult New Zealand white rabbits, received titanium implants were inserted in the tibia. The right side is considered as experime

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 23 2021
Journal Name
Iraqi Journal Of Physics
Thin Film Dye Laser Based on BBQ Doped Poly (Methyl Meth-Acrylate)
...Show More Authors

This paper reports on the laser emission properties of the BBQ dye in poly (methyl meth-acrylate)(PMMA). This host material combines the advantages of an organic environment for dye with the thermoptical mechanical properties of an organic dye. A BBQ dye solid solution in PMMA polymer. A nitrogen laser in untuned laser cavity has pumped thin films. We developed the concentration and the thickness to get high efficiency. The laser efficiency had been increased from 7% at thickness 1.5 m to 16.5% at thickness 3.5m, and from 1% to 10% when concentration increased from 1x10-5M to 1x10-3 M

View Publication Preview PDF