Preferred Language
Articles
/
ijl-236
TREATMENT OF SYMPTOMATIC CERVICAL ECTOPY USING CO2 LASER (10600 nm) – Case Study
...Show More Authors

Background: Cervical ectopy advanced to erosion is one of the common conditions in gynecological and pathological study. It is considered as a physiologic condition resulting from columnar epithelium migration from the cervical canal into the vaginal portion of the cervix, in which no treatment for asymptomatic cervical ectropion can be given. Treatment can be accomplished via thermal cauterization (Electro cautery), Cryosurgery. CO2 laser therapy is another modality of treatment.

Objective: To study the effectiveness of CO2 laser therapy and evaluate it as a biomedical tool for the treatment of cervical ectropion. The study was done at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad during a period of three months from (1st August  to 30th October) 2018.

Methods: Ten female Patients with age range between 22 to 40 years old who attended the private clinic or the outpatient clinic of Al-Imamain Al-Kadhmain Medical City and diagnosed with cervical ectropion. Patients were diagnosed clinically as having cervical ectropion. Pap smear was done   to   all   patients at the Department of Health (Pap smear unit) at Al-Imamain Al-Kadhmain Medical City in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser therapy at a continuous mode. All patients were subjected to continuous wave laser and the range of power from 5 up to 10 Watt. The exposure time ranged from 1-2 minutes.

Results: From all studied patients only three had mild bleeding during procedure and there was no pain reported during procedure except mild pain in two patients. So, simple analgesia (mefenamic acid 500 mg.) was given to them. No need for a prophylactic antibiotic in all patients.  After two weeks follow up, the findings were slight vaginal discharge, no slough. Complete healing of erosion was noticed by the 4th week after procedure.

Conclusion: Laser therapy with CO2 10600nm at specific parameters was effective in treating women with cervical ectropion, which was non-invasive and acceptable by the women as a method of treatment, by laser we can treat precisely the affected area without affecting the surrounding healthy tissue.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 15 2015
Journal Name
Journal Of Physical Vapor Deposition Science And Technology (jpvdst)
Physical Properties of Nanostructured Silicon Dioxide Prepared by Pulsed-Laser Deposition
...Show More Authors

Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Prospect of CW Raman Laser in Silicon- on- Insulator Nano-Waveguides
...Show More Authors
 
Numerical analysis predicts that continuous-wave (CW) Raman lasing is possible in Silicon-On-insulator (SOI) nano-waveguides, despite of presence of free carrier absorption. The scope of this paper lies on lasers for communication systems around 1550 nm wavelength. Two types of waveguide structures Strip and Rib waveguides have been incorporated. The waveguide structures have designed to be 220 nm in height. Three different widths of (350, 450, 1000) nm were studied. The dependence of lasing of the SOI Raman laser on effective carrier lifetime was discussed, produced by tow photon absorption. At telecommunication wavelength of 1550 nm, Raman lasing threshold was calculated to be 1.7 mW in Rib SOI waveguide with dimen
... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic analysis of magnesium-aluminum alloys by laser induced breakdown spectroscopy
...Show More Authors

In this work, the spectra of plasma glow produced by Nd:YAG laser operated at 1.064 μm on Al-Mg alloys with same molar ratio samples in air were analyzed by comparing the atomic lines of aluminum and magnesium with that of strong standard lines. The effect of laser energies on spectral lines, produced by laser ablation, were investigated using optical spectroscopy, the electron density was measured utilizing the Stark broadening of magnesium-aluminum lines and the electron temperature was calculated from the standard Boltzmann plot method. The results that show the electron temperature increases in magnesium and aluminum targets but decreases in magnesium: aluminum alloy target, also show the electron density increase all the aluminum,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Design and Construction of Semiconductor Laser Range Finder for Target Designation
...Show More Authors

The aim of this research is to design and construct a semiconductor laser range finder
operating in the near infrared range for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of 0.904 mm wavelength with a beam expander,
and the receiver with its collecting optics. The characteristics of transmitter pulse width were 200ns and
threshold current 10 Amp. and maximum operating current 38 Amp. The repetition rate was set at 660 Hz
and maximum output power about 1 watt. The divergence of the beam was 0.268o. A special computer
code was used for optimum optical design and laser spot size analysis and for calculation of atmosphere
attenuation.

View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Effect of Laser Energy and Repetition Rate on Holmium Plasma Emission
...Show More Authors

The holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally.  Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 20 2021
Journal Name
Baghdad Science Journal
Multifactor Algorithm for Test Case Selection and Ordering
...Show More Authors

Regression testing being expensive, requires optimization notion. Typically, the optimization of test cases results in selecting a reduced set or subset of test cases or prioritizing the test cases to detect potential faults at an earlier phase. Many former studies revealed the heuristic-dependent mechanism to attain optimality while reducing or prioritizing test cases. Nevertheless, those studies were deprived of systematic procedures to manage tied test cases issue. Moreover, evolutionary algorithms such as the genetic process often help in depleting test cases, together with a concurrent decrease in computational runtime. However, when examining the fault detection capacity along with other parameters, is required, the method falls sh

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref