Preferred Language
Articles
/
ijl-233
Urinary Tract Lithotripsy Using Holmium: YAG (2100nm) Laser
...Show More Authors

Background: Laser urinary stone lithotripsy is an established endourological modality. Ho:YAG(2100nm) laser have broadened  the indications for ureteroscopic stone managements  to include larger stone sizes throughout the whole urinary tract.

Purpose: To evaluate the effectiveness and safety of Holmium: YAG(2100nm) laser lithotripsy with a semirigid uretero scope for urinary stone calculi in a prospective cohort of 17 patients.

Patients and Methods: Holmium: YAG(2100nm) laser lithotripsy was performed with a semirigid ureteroscope in 17 patients from September 2016 to December  2016. Calculi were located in the lower ureter in 9 patients (52.9%), the midureter in 5 (29.4%), and the upper ureter in 3 (17.64%).The parameters used were, average Power(20W),Energy(1.5-2J),Pulse duration(75-100ms),Frequency(10Hz) and Spot size(0.55mm).

Results: The overall stone-free rate was (100%), this rate being for calculi in the lower ureter ,midureter and  for calculi in the upper ureter. Complications occurred in 2 patients (11.76%).The mean operative time(34.9minutes).

Conclusions: Ho:YAG laser lithotripsy is standard in treating ureteric calculi located in the upper, mid and lower ureter. It is able to fragment ureteric stones of all known composition and has an excellent safety profile.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The effect of triggering on the output performance of diode direct face pumping for disc laser in pulse mode
...Show More Authors

The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Simulation of thermal lensing in an end-pumped Nd:YAG laser rod with Gaussian and super-Gaussian pump beam profile
...Show More Authors

A numerical simulation is made on the thermal lensing effect in an laser diode end-pumped Nd:YAG laser rod. Based on finite element method (FEM), the laser rod temperature distribution is calculated and the focal length is deduced for a Gaussian and super-Gaussian pump beam profiles.

At the pump power of 20W, the highest temperature located at the center of end-pumped face was 345K, and the thermal lens focal length was 81.4mm along the x-z axis. 

The results indicate that the thermal lensing effect sensitively depend on the pump power, waist radius of the pump beam and the pump distribution in a laser rod geometry.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Synthesis and characterizations of core-shell SiO2/Au/Ag nano-particles by exploding of wire and pulsed laser plasmas
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Wed Apr 19 2023
Journal Name
Lasers In Medical Science
Immunohistochemistry technique for effect of gold nanoparticles, laser, and photodynamic therapy on FoxP1 level in infected mice with mammary adenocarcinoma
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed May 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of waterlase laser and herbal alternative, green tea and Salvadora Persica (Siwak) extract on push-out bond strength
...Show More Authors

Background: The bond strength of root canal sealers to dentin was important for maintaining the integrity of the seal in root canal filling in both static and dynamic situations. In a static situation, it should eliminate any space that allowed the percolation of fluids between the filling and the wall while in a dynamic situation; it was needed to resist dislodgement of the filling during subsequent manipulation. Materials and Methods: Forty mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments. Instrumentation was done with copious irrigation of 5.25% sodium hypochlorite. Roots were randomly divided into four groups according to the type of cleaning and method of root canal irrig

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Preparation, Characterization & Biological activity for Some Iron(II) Complexes Containing Mixed Ligands (Benzilazine & Semicarbazone) & Study of Laser Effect on Them
...Show More Authors

The research included preparation of new iron(II) complexes with mixed ligands including benzilazine(BA) and semicarbazone ligands {benzilsemicarbazone- BSCH or benzilbis(semicarba-zone)- BBSCH2 or salicylaldehydesemicarbazone- SSCH2 or benzoinsemicarbazone- B'SCH2}.by classical and microwave methods. The resulted complexes have been characterized using chemical and physical methods. The study suggested that the above ligands form ionic complexes having formulae [Fe(SCHi)(BA)(Cl)m](Cl)2-m {where SCH, BSCH, BBSCH2, SSCH¬2 or B'SCH2 ligands; m=1 or 2}. Hexacoordinated mononuclear complexes have been investigated by this study and having octahedral geometries. The effect of laser ray type visible region have been studied on solid ligands and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Sumer 3
Treatment of shallow and deep white spot lesions with three different mouthwashes evaluated by laser fluorescence (an in vitro study)
...Show More Authors

This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Minar International Journal Of Applied Sciences And Technology
STRUCTURAL AND ELECTRICAL PROPERTIES OF (CDO)1-X (V2O5)X PREPARED BY PULSE LASER DEPOSITION TECHNIQUE FOR SOLAR CELL APPLICATIONS
...Show More Authors

In this work ,pure and doped(CdO)thin films with different concentration of V2O5x (0.0, 0.05, 0.1 ) wt.% have been prepared on glass substrate at room temperature using Pulse Laser Deposition technique(PLD).The focused Nd:YAG laser beam at 800 mJ with a frequency second radiation at 1064 nm (pulse width 9 ns) repetition frequency (6 Hz), for 500 laser pulses incident on the target surface At first ,The pellets of (CdO)1-x(V2O5)x at different V2O5 contents were sintered to a temperature of 773K for one hours.Then films of (CdO)1-x(V2O5)x have been prepared.The structure of the thin films was examined by using (XRD) analysis..Hall effect has been measured in orded to know the type of conductivity, Finally the solar cell and the effici

... Show More
View Publication
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of Annealing on Optical and Electrical Properties of ZnS Thin Film Prepared by CO2 Laser Deposition Technique
...Show More Authors

In this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
In vitro Investigation the Antifungal and 940 nm Diode Laser Effects on Inhibition of Candida Albicans Isolated from Oral Cavity
...Show More Authors

Background: Candida albicans is a prevalent commensal that can cause severe health problems in humans. One such condition that frequently returns after treatment is oral candidiasis. Aim: the goal of this research is to evaluate the efficiency of 940 nm as a fungicidal on the growth of Candida albicans in vitro. Material and Methods: In vitro samples (fungal swabs) were taken from the oral cavity of 75 patients suffering from oral thrush. Following the process of isolating and identifying Albicans. The samples are divided into four groups:(Group 1): Suspension of C. albicans was put in a solution of saline as a control group. (Group 2): Suspension of C. albicans that had been treated with nystatin. (Group 3): Suspension of C. albica

... Show More
Crossref (2)
Crossref