Preferred Language
Articles
/
ijl-232
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recorded. The remaining tooth served as control. Samples were prepared for SEM and examined to evaluate dentinal cracks, cemental damage, roughness, filling material-root canal wall interface.

Statistical Analysis: whenever required, x2 test/Fisher exact and Kruskal–Wallis test were used.

Results: laser result in intradentin cracks in 70% of samples while bur cause intradentin crack in 30% of samples. There was no significant difference between group 1 and 2 regarding the percentage of complete and incomplete cracks. Resection with bur resulted in cemental damage in 70% of samples while resection with laser didn’t result in cemental damage in any of the samples .Evaluation of surface roughness revealed statistically significant difference (P ≤ 0.05). The difference in duration of resection was statistically significant while in recorded temperature was not significant.

Conclusion: Er,Cr:YSGG laser showed higher percentage of intradentinal cracks, no cemental damage, larger gap area ,rougher surface and longer time for resection than bur .There is no elevation of temperature on external root surface.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 14 2019
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Comparison of Clinico-Pathological Presentations of Triple-Negative versus Triple-Positive and HER2 Iraqi Breast Cancer Patients
...Show More Authors

BACKGROUND: Breast cancer remains the most common malignancy among the Iraqi population. Affected patients exhibit different clinical behaviours according to the molecular subtypes of the tumour. AIM: To identify the clinical and pathological presentations of the Iraqi breast cancer subtypes identified by Estrogen receptors (ER), Progesterone receptors (PR) and HER2 expressions. PATIENTS AND METHODS: The present study comprised 486 Iraqi female patients diagnosed with breast cancer. ER, PR and HER2 contents of the primary tumours were assessed through immunohistochemical staining; classifying the patients into five different groups: Triple Negative (ER/PR negative/HER2 negative), Triple Positive (ER/PR positive/HER2 positive), Luminal A (ER

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtain

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Reliability Analysis of Multibit Error Correcting Coding and Comparison to Hamming Product Code for On-Chip Interconnect
...Show More Authors

Error control schemes became a necessity in network-on-chip (NoC) to improve reliability as the on-chip interconnect errors increase with the continuous shrinking of geometry. Accordingly, many researchers are trying to present multi-bit error correction coding schemes that perform a high error correction capability with the simplest design possible to minimize area and power consumption. A recent work, Multi-bit Error Correcting Coding with Reduced Link Bandwidth (MECCRLB), showed a huge reduction in area and power consumption compared to a well-known scheme, namely, Hamming product code (HPC) with Type-II HARQ. Moreover, the authors showed that the proposed scheme can correct 11 random errors which is considered a high

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 02 2012
Journal Name
Wasit Journal For Science And Medicine
Field study for the effect of releasing predator Chrysoperla carnea (Stephens) (Neuroptera:Chrysopidae) in comparison with Deltamethrin in controlling cabbage aphid
...Show More Authors

Publication Date
Fri Oct 02 2020
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Jun 03 2020
Journal Name
Political Sciences Journal
The world'srefugeesbetween the aggravation of the situation and the endeavors of international organizations
...Show More Authors

Human witnessed over the centuries many of the important issues faced by the international community was centered on human rights in general and the persecution of refugees, especially according to many forms may be directly or indirectly leaves behind economic crises, social and humanitarian push world countries to rethink the mechanisms and the feasibility of developing agreements and laws and the role of international and regional organizations to protect peoplerefugeestatus.

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Photo Response of Locally Isolated Methicillin-Resistant Staphylococcus aureus to Q-switched Nd:YAG Laser In Vitro Study
...Show More Authors

This prospective study investigates the prevalence of methicillin-resistant S.aureus (MRSA)
in burn unit of Al-Kindy Iraqi hospital, their susceptibility to antibiotics and bactericidal effect of near
infrared light from high powered 1064nm Nd: YAG laser and green light 532nm from SHG Nd: YAG laser
using various energy densities on these bacteria. Twenty four clinical isolates of S.aureus out of sixty
four examined patients with sever burn ulcers.MRSA was associated with 50% of S.aureus infections
.Results of antimicrobial susceptibility revealed that MRSA were multidrug resistant. After laser treatment
of non MRSA with Nd:YAG with wavelength of 1.064nm, 4mm beam diameter, energy density of
0.636 kh/cm2 and 180sec ex

... Show More
View Publication Preview PDF