Preferred Language
Articles
/
ijl-220
Assisted Non-Surgical Therapy of Periodontal Pockets Utilizing Diode Laser: A Randomized Clinical Trial
...Show More Authors

Periodontal diseases are inflammatory diseases, for which, scaling and root planning is the main approach. Diode laser therapy as an adjunct to non-surgical periodontal treatment has shown some beneficial effects.

Aim: The objective of this single randomized controlled clinical study was to assess the effect of a 940 nm diode laser as an adjunct to SRP therapy in the treatment of periodontal pockets.

 Methods: In this study, twenty patients in need of periodontal treatment with periodontal pocket ≥ 4 mm were selected for this split-mouth clinical study. Test group treated by diode laser 940 nm as an adjunct with SRP, control group treated by SRP in contralateral quadrants. Clinical measurements (CAL and BOP) were performed before treatment at baseline and at 3 months.

Results: CAL and BOP were significantly reduced after 3 months in control and laser groups. No significant differences were found between the control and laser groups in respect to CAL and BOP.

Conclusion: The use of the 940 nm diode laser as an adjunct to scaling and root planing did not offer any superior clinical benefits over conventional scaling and root planning.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad
...Show More Authors

This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was  (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, satura

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Simulation of Natural Heat Convection from Finned Vertical Plate with Different Inclinations
...Show More Authors

In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus R

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 26 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Rationalization of Decision –Making and Performance evaluation methods through Employing Strategic Management Accounting
...Show More Authors

This research dealt with the process of reducing costs through some strategic methods of management accounting targeted cost analysis unassembled and Alkeisen, where he focused this research through his theory on a review of some administrative accounting strategic technologies, while the second practical side through the application of targeted cost analysis unassembled and Alkeisen, acquired Search importance of focusing on the decisions to cut costs, through the use of some administrative accounting strategic methods and this we can unassembled analysis, continuous improvement, and the cost of quality) when applied quality, "in light of this has been reached to a set of conclusions that the most important of the  company's relian

... Show More
View Publication
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Using He-Ne laser irradiation for enhancing cartilage Autografts
...Show More Authors

thirty adult NewZealand rabbits used in this study, they were divided in to two groups (control and treaded with Helium — Neon laser). A square skin flap done on the medial aspect of the auricle of both sides, a square piece of cartilage incised, pealed out from each auricle and fixed in the site of the other, then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated using a Helium —Neon laser with (5mw) power for (10 days) began after the operation directly, (3 rabbits) from each group used for collection of specimens for histopathological examination at the weeks (1,2,3,4, & 6) weeks post the operation .The results revealed Early invasion of the matrix with elastic fibers which continue to t

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Is co2 laser Hemorrhoidectomy superior to conventional open Hemorrhoidectomy?
...Show More Authors

Background: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to J

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 12 2006
Journal Name
Iraqi Journal Of Laser
Laser-Induced Low-Resistance Ohmic Contacts on n-Si
...Show More Authors

In the present work, the feasibility of formation near-ideal ohmic behavior of In/n-Si contact efficiently by 300 s duration Nd:YAG pulsed laser processing has been recognized. Several laser pulses energy densities have been used, and the optimal energy density that gives best results is obtained. Topography of the irradiated region was extensively discussed and supported with micrographic illustrations to determine the surface condition that can play the important role in the ohmic contact quality. I-V characteristics in the forward and reverse bias and barrier height measurements have been studied for different irradiated samples to determine the laser energy density that gives best ohmic behavior. Comparing the current results with

... Show More
View Publication Preview PDF
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Engineering
Carbon Nanoparticles Synthesis By Different Nd:Yag Laser Pulse Energy
...Show More Authors

One of the most important techniques for preparing nanoparticle material is Pulsed Laser Ablation in Liquid technique (PLAL). Carbon nanoparticles were prepared using PLAL, and the carbon target was immersed in Ultrapure water (UPW) then irradiated with Q-switched Nd:YAG laser (1064 nm) and six ns pulse duration. In this process, an Nd:YAG laser beam was focused near the carbon surface. Nanoparticles synthesized using laser irradiation were studied by observing the effects of varying incident laser pulse intensities (250, 500, 750, 1000) mJ on the particle size (20.52, 36.97, 48.72, and 61.53) nm, respectively. In addition, nanoparticles were characterized by means of the Atomic Force Microscopy (AFM) test, pH easurement

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Adsorption of Cd(II) and Pb(II) Ions from Aqueous Solution by Activated Carbon
...Show More Authors

Heavy metal consider as major environmental pollutants. Many of industrial wastewater effluents contain a wide range of these heavy metals. The adsorption of Cd2+ and Pb2+ metal ions from aqueous solution by activated carbon was studied. The results showed that maximum adsorption capacity occurred at 486.9×10-3 mg/kg for Pb2+ ion and 548.8×10-3 mg/kg for Cd2+ ion. The adsorption in a mixture of the metal ions had a balancing effect on the adsorption capacity of the activated carbon. The adsorption capacity of each metal ion was affected by the presence of other metal ions rather than its presence individually. The study showed the presence of other heavy metals attribute to the reduction in the activated carbon capacity, and the adsorp

... Show More
View Publication Preview PDF