Preferred Language
Articles
/
ijl-218
Fractional CO2 Laser Treatment of Mild Periorbital Wrinkles in Iraqi Patients
...Show More Authors

Background and Objective: Public demand for procedures to rejuvenate photodamaged facial skin have stimulated the use of fractional CO2 laser as a precise and predictable treatment modality. The purpose of this study was to assess the effect of fractional CO2 laser system for reducing periorbital rhytids.

Materials and Methods: twenty seven subjects with mild periocular wrinkles, and photoaged skin of the face were prospectively treated two to three times (according to clinical response) in the periorbital area with a fractional CO2 laser device equipped with a scanning hand piece. Improvements in eyelid wrinkles was evaluated clinically and photographically. Subjects also scored satisfaction and tolerability.

Results: seventy % of subjects achieved or maintained 50–60% improvement at 3 months. Nearly 40% of subjects maintained 20–40% improvement at 3 months after treatment. Subject satisfaction was high and the procedure was well tolerated. Mild-to-moderate erythema and edema persisted for up to three to four days.

Conclusion: Treatment with a fractional CO2 laser device improves periorbital rhytids, and tightens skin.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Design of L-Band Multiwavelength Laser for TDM/WDM PON Application
...Show More Authors

This paper presents on the design of L-Band Multiwavelength laser for Hybrid Time Division Multiplexing/ Wavelength Division Multiplexing (TDM/WDM) Passive Optical Network (PON) application. In this design, an L-band Mulltiwavelength Laser is designed as the downstream signals for TDM/WDM PON. The downstream signals ranging from 1569.865 nm to 1581.973 nm with 100GHz spacing. The multiwavelength laser is designed using OptiSystem software and it is integrated into a TDM/WDM PON that is also designed using OptiSystem simulation software. By adapting multiwavelength fiber laser into a TDM/WDM network, a simple and low-cost downstream signal is proposed. From the simulation design, it is found that the proposed design is suitable to be used

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jan 17 2015
Journal Name
Iraqi Journal Of Science
Dissemination of Carbapenem resistant Pseudomonas aeruginosa among burn patients in Karbala Province\IraqDissemination of Carbapenem resistant Pseudomonas aeruginosa among burn patients in Karbala Province\Iraq
...Show More Authors

In this study, 158 clinical samples were collected from hospitalized burn patients during the period from December 2012 to June 2013 in Karbala province\ Iraq. Bacterial isolates were identified using conventional biochemical tests and then identification was confirmed by using Vitek-2 compact system. Pseudomonas aeruginosa recovery was 60 isolates in this study. These isolates were analyzed for antibiotic susceptibility by the disk diffusion test (DDT) according to Kirby Bauer's method using seven clinically important antipseudomonal agents: carbapenems (Imipenem and Meropenem), pencillins (Piperacillin), cephalosporins (Ceftazidim), monobactam (Aztreonam), quinolones (Ciprofloxacin) and aminoglycosides (Gentamicin). The results of resista

... Show More
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
An In Vitro Histological Study of Human Skin Wound Soldering Using 980 nm Diode Laser in Continuous versus Pulsed Modes.
...Show More Authors

Laser skin wound soldering offers many distinct advantages over conventional closure and laser welding techniques. Objective : to compare the histological effects of human skin wound soldering using 50 % human albumin solder and compound charcoal photosensitiser with 980 nm diode laser acting in various modes of action and parameters. Study Design/Materials and Methods: In this in vitro experimental study , Multiple 3-4 cm long full thickness incisions in a specimen of human skin were soldered using a 4 mm spot diameter beam of 980 nm diode laser(at different laser parameters and modes of action) with 50 % human albumin solder mixed with the compound charcoal at 5 % W/V concentration .After obtaining a successful wound soldering , the wo

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 08 2026
Journal Name
Mesopotamian Journal Of Artificial Intelligence In Healthcare
Design and Implementation of an Intelligent Electronic Circuit to Control Laser Power in Real Time Using Built-In Thermal Feedback
...Show More Authors

View Publication
Scopus
Publication Date
Fri Jun 30 2006
Journal Name
Journal Ibn-alhaitham Jornal For Applied And Pure Sciences
A Study of Soluble Proteins(Spl and Sp2) Effect of extracted from Proteus mirabilis on the Activity of Superoxide Dismutase,SOD in the Sera of albino rabbit
...Show More Authors

The aim of this study is to shed light on the immunological effect of soluble protein extracted from Proteus mirabilis through employing the level of the enzymatic activity of superoxide dismutase ,SOD The Soluble proteins, SP1 and SP2,were extracted by using the lysozyme enzyme . The rabbit were divided into three groups. the first one was injected with SP1 , the second group with SP2 for four weeks while the third group were untreated. The results revealed that enzymatic activity of SOD was increased significantly in the fifth week of injection withSP1 in comparison with control.

Publication Date
Sun Jan 01 2006
Journal Name
Smj
Treatment of alopecia areata by topical diclofenac sodium gel in comparison with benzoyl peroxide gel
...Show More Authors

KE Sharqie, AA Al-Nuaimy, WJ Kadhum, SMJ, 2006 - Cited by 2

View Publication
Publication Date
Fri Apr 01 2016
Journal Name
Water
The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection
...Show More Authors

View Publication
Scopus (43)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Wed Apr 06 2016
Journal Name
Journal Of Water And Health
The effect of chlorine and combined chlorine/UV treatment on coliphages in drinking water disinfection
...Show More Authors

Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3–0.5 mg/L total chlorine (free Cl-dosage 0.12–0.21 mg/L) for 10 min achieved 2.5–5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentra

... Show More
View Publication
Scopus (39)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
The Influence of Ablation Speed on the Synthesis of Carbon Nanostructures Via Pulsed Laser Ablation of Asphalt in Ethanol
...Show More Authors

Pulsed liquid laser ablation is considered a green method for the synthesis of nanostructures because there are no byproducts formed after the ablation. In this paper, a fiber laser of wavelength 1.064 µm, peak power of 1 mJ, pulse duration of 120 ns, and repetition rate of 20 kHz, was used to produce carbon nanostructures including carbon nanospheres and carbon nanorods from the ablation of asphalt in ethanol at ablation speeds of (100, 75, 50, 10 mm/s).  The morphology, composition and optical properties of the synthesized samples were studied experimentally using FESEM, HRTEM, EDS, and UV-vis spectrophotometer. Results showed that the band gap energy decreased with decreasing the ablation speed (increasing the ablation time), the mi

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref