Preferred Language
Articles
/
ijl-208
Stress Urinary Incontinence Treatment Using Vaginal Fractional CO2 Laser (10600nm)
...Show More Authors

Stress urinary incontinence (SUI) is involuntary urine leakage during activities that increase abdominal pressure such as coughing, sneezing and lifting of heavy weights. This is a very common disorder among women with history of multiple vaginal deliveries with an obstructed labor. SUI is considered one of the most distressing problems, especially for younger women, with severe quality of life implications, it caused by the loss of urethral support, usually as a consequence of the supporting structural muscles in the pelvis.

Objective: To prove and demonstrate the effect of a fractional CO2 micro-ablative laser (10600nm) in intra vaginal therapy for treating SUI and achieve a clinical improvement of the urogenital system support.

Methods: This is a prospective, observational study which was conducted over six month from the 1st . of July to 29th of December 2016 in Consultation Gynecologist Clinic in Al-Hila city, Iraq, in patients who complain of SUI. Twenty female patients were included in the study, their age ranged from 30- 69 year, at range (49.5 year ) fifteen patient delivered vaginally, two delivered by cesarean section, two had combined delivery and one was Nulliparous ,all of them received the same treatment protocol. Detailed history about continence assessment, quality of life and sexuality before and after therapy. The fractional CO2 Aphrodite laser was used. The parameters used in each session were energy/(dot)pixel 119.4mJ, pulse duration 900 μs, frequancy1000Hz, and exposure time 300ms /shot with average of shots 34 and in range 26-42, in three sessions four weeks apart between them. The patients were followed for three months started from the beginning of the second session to one month after the last session.

 Results: Thirty-five percent of patients 35%(n=7) were cured ,and these 35% included all patients delivered by cesarean section and one third of patients who delivered vaginally and extensively most of patients were 60%(n=12) improved of their SUI. Patient reported no leakage any more while coughing or sneezing. Only 5%(n=1) not responded was menopause women.

Conclusions: This study shows that micro-ablative fractional CO2 laser is effective can produce a remodeling of vaginal connective tissue without causing damage to surrounding tissue and the group of patients with continence disorder without vaginal delivery achieved marked improvement .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 07 2025
Journal Name
Scientific Reports
Evaluation of how laser photostimulation at two wavelengths alters the antimicrobial potential of Streptomycetes spp
...Show More Authors

The purpose of this study was to isolate and identify additional products produced by direct laser irradiation, as well as to ascertain if laser irradiation may stimulate the synthesis of antibiotic compounds in a local Streptomycetes (Strept). Moreover, we postulate the mechanisms by which lasers function within living bacterial cells and suggest that sequential photochemical reactions may transpire following a designated period of irradiation. Thiophene was found as one of the most significant clinical products with antibacterial and anticancer properties. To accomplish these objectives, we selected two isolates: Streptomyces thinghirensis strain S10 (Strept thin), which inherently synthesizes an antibacterial agent, and Streptomyces lien

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Study the Effect of solvent on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include studies the effect of solvent of dye doped in polymeric laser sample which manufactured in primo press way, which is used as an active (R6G) tunable dye lasers. The remarks show that, when the viscosity of the solvent (from Pure Water to Ethanol), for the same concentration and thickness of the performance polymeric sample is increased, the absorption spectrum is shifts towards the long wave length (red shift), & towards short wave length (blue shift) for fluorescence spectrum, also increased the quantum fluorescence yield. The best result we obtained for the quantum fluorescence yield is (0.882) with thickness (0.25mm) in Ethanol solvent in concentration (2*10-3mole/liter), while when we used the Pure Water as a solvent,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Design and Construction of a Testing Platform and Estimating Attenuation Painting Reflectivity to Laser Beam
...Show More Authors

The project has been described the design and construction of a reliable optical testing platform used for evaluate the reflectivity of metal surfaces treated with special paintings required for laser beam attenuation. The platform comprises an Nd-YAG laser system which has been designed and fabricated with specifications to be compatible with their corresponding in laser range finder transmitters used for various applications. The reflectivity of various attenuating paintings, at different detection angles, has been observed. Moreover, the variation of the reflected energy with painting type and metal type to be painted has been studied experimentally. Results illustrated the existence of a definite angle, at which the reflectivity was max

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Plasma characteristics of Ag:Al alloy produced by fundamental and second harmonic frequencies of Nd:YAG laser
...Show More Authors

In this work, the spectra for plasma glow produced by pulse
Nd:YAG laser (λ=532 and 1064nm) on Ag:Al alloy with same molar
ratio samples in distilled water were analyzed by studying the atomic
lines compared with aluminum and silver strong standard lines. The
effect of laser energies of the range 300 to 800 mJ on spectral lines,
produced by laser ablation, were investigated using optical
spectroscopy. The electron temperature was found to be increased
from 1.698 to 1.899 eV, while the electron density decreased from
2.247×1015 to 5.08×1014 cm-3 with increasing laser energy from 300
to 800 mJ with wavelength of 1064 nm. The values of electron
temperature using second harmonic frequency are greater than of<

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for SnO2 doped ZnO prepared by pulse Nd:YAG laser deposition
...Show More Authors

 In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located  that  The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.

View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Tue Jul 14 2020
Journal Name
Materials Science Forum
The Cyclic Fatigue Behavior for 6061-T6 Al Alloy Shafts Processed by Laser Shock Peening
...Show More Authors

The optimal combination of aluminum quality, sufficient strength, high stress to weight ratio and clean finish make it a good choice in driveshafts fabrication. This study has been devoted to experimentally investigate the effect of applying laser shock peening (LSP) on the fatigue performance for 6061-T6 aluminum alloy rotary shafts. Q-switched pulsed Nd:YAG laser was used with operating parameters of 500 mJ and 600 mJ pulse energies, 12 ns pulse duration and 10 Hz pulse repetition rate. The LSP is applied at the waist of the prepared samples for the cyclic fatigue test. The results show that applying 500 mJ pulse energy yields a noticeable effect on enhancing the fatigue strength by increasing the required number of cycles to fracture the

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effects of Laser Energy on n-Ge/p-SnS Hetrojunction Diode Detector in Different Environments
...Show More Authors

In the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Laser And Particle Beams
Surface morphology modifications of human teeth induced by a picosecond Nd:YAG laser operating at 532nm
...Show More Authors

Scopus (11)
Scopus
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Transfocation Technique to Overcome Atmospheric Scintillation Effect on a Laser Detection and Tracking System (LDTS)
...Show More Authors

Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Incident Laser Power and Concentration Effects on the Fluorescence of DCM Dye in PMMA Polymer
...Show More Authors

Incident laser power and concentration effects on fluorescence emission from DCM dye in PMMA polymer have been investigated. Different concentrations of the dye were used. It was found that the fluorescence intensity increased with increasing of the concentration of the dye, with a red shift. In addition, it was found that the fluorescence intensity increased with the increase of the incident laser power I0.

View Publication Preview PDF