The present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two groups. Maculopathy was regressed in 32/41 treated eyes, 23/24 with maculopathy and non-proliferative diabetic retinopathy are treated by grid laser photocoagulation, 9/17 with proliferative diabetic retinopathy and maculopathy are treated by grid combined with pan retinal photocoagulation. Maculopathy was unchanged in 7/41, deterioration in 2/41. Visual acuity improved in 8/41 patients one line of Snellen chart in young patients with shorter duration and non- proliferative diabetic retinopathy, and good visual acuity prior to therapy and 31/41 stabilized visual acuity for the follow up period, 2/41 deterioration of visual acuity by one line of Snellen chart with progression of edema, hemorrhage and exudation, 3/41 patients complain of paracentral scotoma one-week post treatment improved gradually after 2 weeks. Higher power density is needed to treat the diffuse form of maculopathy regarding the severity of maculopathy and macular edema. The power density needed to have the desired effect is less in more pigmented fundus than in fair fundus in order to have the same effect.
Objective: The descriptive study was used to evaluate nursing staff performance in cardiac care units at teaching
and non teaching hospitals in kirkuk city: A comparative study.
Methodology: A descriptive study was used to evaluate nursing staff performance in cardiac care units. The study
was conducted from December 29th
, 2013 up to the 27th of Apr. 2014. A non-probability (purposive) sample of
(44) nurses who work in cardiac care unit at Azady teaching Hospital and Kirkuk general Hospital was evaluated by
a questionnaire which consisted of two parts; the first part is concerned with the demographic characteristics of
the nurses and the second part concerned Observation check list for evaluation nursing staff Perfo
Background: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® co
... Show MoreMore than 450 distinct types of human papilloma virus recognized via recent molecular techniques. The low and high oncogenic risk-HPV genotypes have an association with a variety of benign and malignant tumors in the oropharyngeal and nasopharyngeal localizations. This study aimed to determine the rate of DNA detection of HPV genotype 6/11 in non-oncologic nasopharyngeal and palatine tonsillar tissues from pediatric patients subjected to adeno-tonsillectomies. A total number of 64 tissue specimens enrolled; 44 non-oncologic nasopharyngeal and palatine hypertrophied tissue specimens from 22 pediatric patients sustained combined adeno-tonsillectomies and compared to 20 nasal trimmed tissues with unremarkable pathological changes (in
... Show MoreThe combined system of electrocoagulation (EC) and electro-oxidation (EO) is one of the most promising methods in dye removal. In this work, a solution of 200 mg/l of Congo red was used to examine the removal of anionic dye using an EC-EO system with three stainless steel electrodes as the auxiliary electrodes and an aluminum electrode as anode for the EC process, Cu-Mn-Ni Nanocomposite as anode for the EO process. This composite oxide was simultaneously synthesized by anodic and cathodic deposition of Cu (NO3)2, MnCl2, and Ni (NO3)2 salts with 0.075 M as concentrations of each salt with a fixed molar ratio (1:1:1) at a constant current density of 25 mA/cm2. The characteristics structure and surface morphology of the depo
... Show MoreIn the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show MoreThis study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu
... Show MoreThe current study was designed to evaluate the anti-inflammatory effect of GKB in the rat model of granulomatous inflammation. Thirty rats were distributed into five groups: The first group served as negative control group that received distilled water (DW) only without inducting inflammation, positive control group; treated with DW with the induction of inflammation and they were assigned to cotton pellet-induced granuloma, ginkgo biloba (GKB) treated group (200mg/kg/day), dexamethasone-treated group (1mg/kg), and Prednisolone treated group (5mg/kg). All the treatments were given orally for seven consecutive days. On day eight, the rats were anesthetized and the pellets together with granulation tissue were carefully removed
... Show MoreLasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.
This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.
For the design of a deep foundation, piles are presumed to transfer the axial and lateral loads into the ground. However, the effects of the combined loads are generally ignored in engineering practice since there are uncertainties to the precise definition of soil–pile interactions. Hence, for technical discussions of the soil–pile interactions due to dynamic loads, a three-dimensional finite element model was developed to evaluate the soil pile performance based on the 1 g shaking table test. The static loads consisted of 50% of the allowable vertical pile capacity and 50% of the allowable lateral pile capacity. The dynamic loads were taken from the recorded data of the Kobe e