to evaluate the effect of various Nd:YAG frequency doubled laser parameters on the acid
dissolution and the progression of in vitro caries like lesions in human enamel.
Materials and Methods: Human extracted caries free upper first premolar teeth were collected for
this study. The irradiated teeth were divided into two groups. The first group was irradiated with
continuous Nd:YAG laser radiation, and the second group was irradiated with chopped Nd:YAG laser
radiation. For the first group, power and exposure time were changed while for the second group
power and number of pulses were changed. The spot diameter was kept constant for all the samples.
Results: using 1.5 W and 3 seconds (exposure time), best results among the continuous group were
obtained, while in the chopped group using 1.5 W and 3 pulses gave better result. The percent
reduction in lesion depth in this study was up to 26% in the continuous group, whereas in the chopped
group was up to 44%.
Background: Any child with Down's syndrome does not develop in the same manner as normal child. Therefore, the child should not be viewed as being like everyone else. Developmental enamel defects in primary teeth have been found at least twice as frequently in disabled children as in control children. Down's syndrome consumed protein more than the recommended daily allowance compared to other disabled groups. Therefore, the aim of this study was to investigate developmental defects of enamel and their relations to nutrient intake among Down's syndrome children in comparison to normal children. Materials and Methods: A sample consisted of fifty institutionalized Down's syndrome children (study group) and 50 normal children (control group)
... Show MoreBackground: Stress urinary incontinence is a frequent urological disease in women; it has a great influence on an individual’s wellbeing and places a significant economic strain on any health service. The placement of urodynamic diagnostic tests in the evaluation route is an important clinical research concern in this field.
Objective: to find out whether the duration of stress urinary incontinence is associated with the finding of bladder outlet obstruction in urodynamic study or not.
Subjects and Methods: A descriptive study. With enrolled female patients had symptomatic Stress urinary incontinence as their primary complain. All the included patients w
... Show MoreCurcumin is a yellow pigment produced from the rhizomes of the Curcuma longa plant and a primary chemo preventive component of turmeric is used as a spice and food coloring ingredient. Curcumin has a large number of pharmacological activities, such as anticancer, anti-diabetic, antioxidant, anti-infectious, and anti-inflammatory properties.Investigation of the geno-protective effect of curcumin on methotrexate induces chromosomal aberrations of spleen and bone marrow cells. In this study, 32 mice were used and divided into four groups (eight mice at each group) as follows: Group1 (negative control): Dimethyl sulfoxide was given intraperitoneally to mice every day for ten days.Group2 (positive control): Mice were received a single do
... Show MoreIn this work, the possibility of a multiwavelength mode-locked fiber laser generation based on Four-Wave Mixing (FWM) induced by Fe2O3-SiO2 nanocomposite material is investigated for the first time. A multiwavelength mode-locked pulses fiber laser are generated from Ytterbium–doped fiber laser (YDFL) due to the combined action of high nonlinear absorption and high refractive coefficients of Fe2O3-SiO2 nanocomposite incorporated inside YDFL ring cavity. Up to more than 20 lasing lines in the 1040–1070 nm band with an equally lines separation of ~0.6 nm have been observed by just simple variation of passive modulation of the state of the polarization and the pump power altogether. Moreover, a passively mode-locked operation of YDFL laser
... Show MoreThis work has been done with using of epoxy resin mixed with Granite powder were weighted by percent volume (5,10,15, and 20)%and then mixed with epoxy polymer to compose polymer composite. Hand lay-up technique is used in fabrication of the composite samples. Hardness test was carried out for the proper samples in both normal condition and after immersion in HCL (1 M and 2 M) solutions for periods ranging up to 10 weeks. After comparing the results between the polymer and their composite, the hardness increased with increasing Granite weight percent, it was found that Hardness were greater for the composites before immersion compared with their values after immersion.
This study aims to suggest a technique for soil properties improvement of AL- Kadhimin shrine Minaret and to support the foundation, which has a tilt of roughly 80 cm from the vertical axis. The shrine of the AL- Kadhimin is made up of four minarets with two domes set in a large courtyard. The four minarets have skewed to varying degrees due to uncontrolled dewatering inside the shrine in recent years. However, the northeast minaret was the most inclined due to its proximity to the well placed inside shrine courtyard. When the well near the minaret is operated, the water level drops, increasing the effective stresses of the soil and causing differential settling of the minaret foundation. To maintain the minaret's foundation from potenti
... Show MoreZSM-5 zeolite was synthesis under hydrothermal conditions at 175oC. The synthesis parameters have been investigated to find optimum synthesis method. Firstly, the crystallization time has been investigated to find the optimum crystallization time. Also, the ageing time was studied. The morphology, structure, and composition of the synthesized ZSM-5 zeolite were characterized using scanning electron microscopy (SEM), pH meter, viscometer, and X-ray powder diffraction (XRD). The bulk Si/Al ratio of ZSM-5 zeolite was in the range of 9.5—11.7. The synthesized ZSM-5 zeolite with appropriate ageing time could adjust crystal size and degree of the crystallinity. The crystal size of ZSM-5 zeolite obtained at an agei
... Show MoreIn this research the natural frequency of a cracked simple supported beam (the crack is in many places and in different depths) is investigated analytically, experimentally and numerically by ANSYS program, and the results are compared. The beam is made of iron with dimensions of L*W*H= (0.84*0.02* 0.02m), and density = 7680kg/m3, E=200Gpa. A comparison made between analytical results from ANSYS with experimental results, where the biggest error percentage is about (7.2 %) in crack position (42 cm) and (6 mm) depth. Between Rayleigh method with experimental results the biggest error percentage is about (6.4 %) for the same crack position and depth. From the error percentages it could be concluded that the Rayleigh method gives
... Show More