Preferred Language
Articles
/
ijl-156
Evaluation of 532 nm Laser Effect on Dental Enamel Dissolution: In Vitro Study
...Show More Authors

to evaluate the effect of various Nd:YAG frequency doubled laser parameters on the acid
dissolution and the progression of in vitro caries like lesions in human enamel.
Materials and Methods: Human extracted caries free upper first premolar teeth were collected for
this study. The irradiated teeth were divided into two groups. The first group was irradiated with
continuous Nd:YAG laser radiation, and the second group was irradiated with chopped Nd:YAG laser
radiation. For the first group, power and exposure time were changed while for the second group
power and number of pulses were changed. The spot diameter was kept constant for all the samples.
Results: using 1.5 W and 3 seconds (exposure time), best results among the continuous group were
obtained, while in the chopped group using 1.5 W and 3 pulses gave better result. The percent
reduction in lesion depth in this study was up to 26% in the continuous group, whereas in the chopped
group was up to 44%.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Relationship and impact of the Analysis and evaluation jobs with employees performance : Survey study
...Show More Authors

        The aim the research that definition on the impact a lot of Analysis and evaluation jobs impact in support the employees performance the property that are Analysis and evaluation jobs is one of the jobs however of the human resource management on organization and the impact footpace big on the chractericties and performance of the people and the impact that success of the organization , And here problem stool of the research in the omission the role for the Analysis and evaluation jobs impact in support the employees performance from the upward management in the organization , Polls were adopted as tools for obtaining data and the Depart

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Dose Dependent Anti-inflammatory Effect of Ammi majus Alcoholic Extract in Rat: Chronic Study
...Show More Authors

During treatment of inflammatory diseases, many conventional therapies (non-steroidal anti-inflammatory drugs) used to relief pain and inflammation. Chronic use of  the intended drugs is frequently associated with serious side effect, which may lead to discontinuation of treatment . The efficacy and dose- response effect of ammi majus extraxt  (2 , 4, 8 , 16, and 32 mg/rat) were assessed using  formalin to induce paw edema in rats as a model of chronic inflammation respectively. In this study,  42 rats were used and allocated into 7  groups each containing 6 rats, representing control (Distilled  water) , standard (piroxicam ) and test extract ( 2 , 4 , 8 , 16 and 32 mg/rat of Ammi majus alcoholic e

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Laser Induced Fluorescence Spectroscopy of Decamethylrhenocene ( - C5 Me5)2 Re in Supersonic Jet
...Show More Authors

In this paper we report the use of supersonic jet laser induced fluorescence (LIF) spectroscopy to facilitate the study of the spectra of some organometallic sandwich compounds particularly the metallocenes. The charge-transfer processes within these compounds, especially ligand to metal charge transfer within decamethylrhenocene ( - C5 Me5)2 Re were of particular interest. The spectrum shows a high degree of structures, indicating that there are several levels populated and these molecules are able to undergo many possible transitions

View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance

... Show More
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Preparation of Ag nanoparticles via pulsed laser ablation in liquid for biological applications
...Show More Authors

Ag nanoparticles were prepared using Nd:YAG laser from Ag matel in distilled water using different energies laser (100 and 600) mJ using 200 pulses, and study the effect of the preparation conditions on the structural characteristics of and then study the effect of nanoparticles on the rate of killing the two types of bacteria particles (Staph and E.coli). The goal is to prepare the nanoparticle effectively used to kill bacteria.

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Design and Simulation of Optical Element Use in Solid State Blue Laser Source
...Show More Authors

Solid state blue laser source is a solid state laser include generation of IR laser light 1064 nm and companied with other wavelength 810 nm that invented from other active medium (Tm:ZBLAN) and non-linear crystal (CLBO) are used to generate fourth harmonic of the resultant wavelength 1874 nm that is blue laser light of 460nm. Several optical component have been designed by multilayer dielectric structure and anti reflection coating analysis. By using MATLAB soft ware, the simulation done and used the following non linear material (ZrO2, HfO2, MgO, SiO, Ta2O5 CaF2) and other linear material (ZnO, MgF2, GaAs, AlAs, BaF2, LiF, TiO2) as coating material. The result showed that as more quarter wave layers are added to the structure, the refl

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2015
Journal Name
Materials Science And Engineering: C
Antibacterial activity of magnetic iron oxide nanoparticles synthesized by laser ablation in liquid
...Show More Authors

In this study, (50–110 nm) magnetic iron oxide (α-Fe2O3) nanoparticles were synthesized by pulsed laser ablation of iron target in dimethylformamide (DMF) and sodium dodecyl sulfate (SDS) solutions. The structural properties of the synthesized nanoparticles were investigated by using Fourier Transform Infrared (FT-IR) spectroscopy, UV–VIS absorption, scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). The effect of laser fluence on the characteristics of these nanoparticles was studied. Antibacterial activities of iron oxide nanoparticles were tested against Gram-positive; Staphylococcus aureus and Gram-negative; Escherichia coli, Pseudomonas aeruginosa and Serratia marcescens. The results sh

... Show More
View Publication
Scopus (224)
Crossref (222)
Scopus Clarivate Crossref
Publication Date
Thu Feb 19 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and mechanical evaluation of the osseointegration of titanium implants by the modifications of thread design and/or coating with flaxseed (An experimental study on rabbits)
...Show More Authors

Background: Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and improve implant therapy.Implant threads should be designed to increase surface contact areathat induced better stability. In addition, implant surface coating with Flaxseed was used to enhance bone formation at the bone-implant interface. Materials and methods: Ninety-six commercially pure titanium (CpTi) screws were implanted in rabbits' tibiae and divided into three groups as dual-threaded group, flaxseed-coated group and control group. All groups were evaluated mechanically, histologically and radiographically after each healing periods (2, 4, 6 and 8) weeks and the resulting data were statistically analy

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
The Scientific World Journal
An In Vitro Assessment of Gutta-Percha Coating of New Carrier-Based Root Canal Fillings
...Show More Authors

The first aim of this paper was to evaluate the push-out bond strength of the gutta-percha coating of Thermafil and GuttaCore and compare it with that of gutta-percha used to coat an experimental hydroxyapatite/polyethylene (HA/PE) obturator. The second aim was to assess the thickness of gutta-percha around the carriers of GuttaCore and HA/PE obturators using microcomputed tomography (μCT). Ten (size 30) 1 mm thick samples of each group (Thermafil, GuttaCore, and HA/PE) were prepared. An orthodontic wire with a diameter of 0.5 mm was attached to the plunger of an Instron machine in order to allow the push-out testing of the gutta-percha coating. Five samples of (GuttaCore and HA/PE) were scanned using

... Show More
View Publication Preview PDF
Crossref (6)
Crossref