In humans, Pseudomonas aeruginosa is the second most frequent gram negative nosocomial pathogen in hospitals and has the highest case-fatality rate of all hospital-acquired bacteremia because of the hardy resistance of these bacteria to mechanical cleansing as well as to disinfectant, and many antibiotics. The susceptibility of bacteria against the antibiotics is modulated by several local factors such as temperature which modified drug efficacy, so this study was carried out to evaluate the effect of different temperature (20,42,45)Ċon the susceptibility of Pseudomonas aeruginosa to the minimum inhibitory concentrations (MIC) of the antimicrobial agents before and after irradiation. The samples collected from 150 persons suffering from burns-wounds infections, thirty-five isolates of pseudomonas aeruginosa bacteria were obtained depending on morphological and biochemical tests. Following exposure of Pseudomonas aeruginosa isolates to the diode laser with 805nm wavelength,3W output power and (5,10,15) minutes exposure times in combination with different temperature and different concentrations of ( cefotaxim, amikacin, chloramphenicol) antibiotics, highly observable change in the MIC value was achieved , the bacterial isolates became sensitive to chloramphenicol at the three exposure times and 100% killing of the cells was observed at 15 minutes exposure time at temperature 45Ċ in absence of the antibiotics. In conclusion, 3W diode laser in combination with temperature 45Ċ was the best condition that reduces the MIC value, and killing bacteria at 10 minutes exposure time.
Introduction
Since the last century, the laser occupied a large degree of attention in the scientific and technological fields. Invention of laser causes a chain of important changes in the science development especially in physics, chemistry, biology and electronics, in addition to its industrial and medical applications. For this reason the laser enters in many fields and introduces solution to many problems.
Many lasers have been used successfully for treating many cases of infection that caused by bacteria such as E.coli, Staphylococcus aureus and Pseudomonas aeruginosa. The resistance of Pseudomonas aeruginosa to many antibiotics form a big problem, especially in burns and wounds infections. Many studies have been introduced to investigate the effect of laser on microorganisms,a lotof their were related to the susceptibility of bacteria to antibiotics. This work is a trial in this regard.
Pseudomonas aeruginosa
One of the most common microorganisms encounted in hospital infection. It was isolated from various sources like air, floor, sinks and even disinfectant (Iglewski, 1980).
Pseudomonas aeruginosa is frequently present in
This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic
Time-domain spectral matching commonly used to define seismic inputs to dynamic analysis in terms of acceleration time history compatible with a specific target response spectrum is used in this study to investigate the second-order geometric effect of P-delta on the seismic response of base-isolated high-rise buildings. A synthetic time series is generated by adjusting reference time series that consist of available readings from a past earthquake of the 1940 El Centro earthquake adopted as an initial time series. The superstructure of a 20-story base isolated building is represented by a 3-D finite element model using ETABS software. The results of the base isolated building show that base isolation technique significantly reduces inter-s
... Show MoreThe goal of the extant revision was to explore the influence of caffeic acid (CA) extracted from Arctium lappa L. on lipid profile and histology of aorta in rats . Analytical study demonstrated a high percentage of both chlorogenic and caffeic acid in the 80 % methanol extract of the aerial parts (leaves and stems) of Arctium lappa L. from the family Asteraceace. Hypolipidemic activity of caffeic acid was studied against cholesterol induced hypercholesterolemia in Wistar albino rats for thirty days. Rats were separated into normal group (A), hypercholesterolemic positive controller group (B). While, the rest three groups (C, D and E) attended as hypercholesterol
... Show MoreThree types of extracts ( aquatic, alcoholic, and oily ) were prepared from the fruits of coconuts, and a series of chemical tests were conducted in addition to the use of the FTIR equipment to determine the active locations in the prepared extracts. The results indicated the presence of active compounds (tannins, saponins, flavonoids, turbines and steroids) in the extracts prepared from the fruits of coconuts, also the antimicrobial capability of these extracts were tested on pathogenic bacteria isolated from wounds and burns infections cases. The results proved that the concentration 80 mg/ml of the aquatic extract is the minimum inhibitory concentration for the microbes: Proteus vulgaris and Pseudomonas fluorescence, while the
... Show MoreABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show MoreIn this paper deals with the effect laser irradiation on the optical properties of cobalt oxide (CoO2) thin films and that was prepared using semi computerized spray pyrolysis technique. The films deposited on glass substrate using such as an ideal value concentration of (0.02)M with a total volume of 100 ml. With substrate temperature was (350 C), spray rate (15 ml/min).The XRD diffraction given polycrystalline nature with Crystal system trigonal (hexagonal axes). The obtained films were irradiated by continuous green laser (532.8 nm) with power 140 mW for different time periods is 10 min,20min and 30min. The result was that the optical properties of cobalt oxide thin films affe