Incident laser power and concentration effects on fluorescence emission from DCM dye in PMMA polymer have been investigated. Different concentrations of the dye were used. It was found that the fluorescence intensity increased with increasing of the concentration of the dye, with a red shift. In addition, it was found that the fluorescence intensity increased with the increase of the incident laser power I0.
Radiological assessment for the East Baghdad oilfield-southern part was conducted in the current study. 10 samples (scale, soil, sludge, water, and oil) from the different stages of oil production were collected. 232Th, 226Ra, and 40K in the samples were analyzed with 40% efficiency for Gamma spectrometry. system based on HPGe. The findings indicated that the examined sites exhibit comparatively lower levels of NORM contamination, in contrast to other global oilfields. Nevertheless, certain areas, particularly those within separation stages, demonstrate relatively elevated NORM concentrations exceeding the global average in soil and sludge. The maximum value of 226Ra, 232Th, was found in sludge sample the findings indicated that ove
... Show MoreThe aim of this research is to demonstrate the impact of credit risk on the banks of the study sample on the granting of loans and credit facilities, and try to reduce the size of credit risk to banks as a result of granting loans and credit facilities, credit risk is the oldest form of risk in financial markets. Every financial institution takes a degree of risk when it gives loans and credit facilities to companies and customers, It is exposed to financial losses when some borrowers fail to repay their loans as agreed, and at the same time credit facilities are the most profitable operations of the bank as it is the most profitable banking operations than other operations, so it represents the research communit
... Show MoreThis research aims to analyze the effect between letter of credit opening and implementation procedures which considered one of the most important Foreign services submitted by bank institutions to their customers on Time contracted time limit commitment contract by some Iraqi commercial banks, descriptive analytical method used in This research The questionnaires designed a tool main research to gather information to get to know the effect , Seventy questionnaire forms were distributed, sixty seven forms were analyzable , The answers were analyzed by the arithmetic mean and standard deviation and test the level of influence between variables simple linear regression. The result showe
... Show MoreAbstract
Praise be to Allah and prayers and peace be upon our Prophet, Muhammad, his family and all of his companions,
This research addresses the issue of judge's preaching to the litigants and witnesses; it is a very significant issue since the judge cannot know the insides and facts, but it issues judgments based on the hearings. Since people are originally wrong-doing and ignorant, they, therefore, commit injustice, oppression, false adversarial, and false testimony. However, some people can possibly retreat and return to the right, after being inattentive or recalcitrant, by preaching. This fact led scholars to talk about the judge's preaching to litigant and witnesses and this research is conducted
... Show MoreHighly-fluorescent Carbon Quantum Dots (CQDs) are synthesized in simple step by hydrothermal carbonization method of natural precursor such as orange juice as a carbon source. Hydrothermal method for synthesized CQDs requires simple and inexpensive equipment and raw materials, thus this method are now common synthesis method. The prepared CQDs have ultrafine size up to few nanometers and several features such as high solubility in water, low toxicity, high biocompatibility, photo-bleaching resistant, Chemical inertness and ease of functionalization which qualifies it for use in many applications such as bio-imaging, photo-labeling and photo-catalysis.
This research demonstrates the
... Show MoreIn this research, the dynamics process of charge transfer from the sensitized D35CPDT dye to tin(iv) oxide( ) or titanium dioxide ( ) semiconductors are carried out by using a quantum model for charge transfer. Different chemical solvents Pyridine, 2-Methoxyethanol. Ethanol, Acetonitrile, and Methanol have been used with both systems as polar media surrounded the systems. The rate for charge transfer from photo-excitation D35CPDTdye and injection into the conduction band of or semiconductors vary from a to for system and from a to for the system, depending on the charge transfer parameters strength coupling, free energy, potential of donor and acceptor in the system. The charge transfer rate in D35CPDT / the syst
... Show MoreSynthesis of new Fe+3, Co+2, Cu+2, Ru+3, and Rh+3 complexes of azo ligand; [5-((2-(3 H-1 indol-3-yl) ethyl) diazenyl) quinolin-8-ol], of 1:2 (M: L) and characterized through various techniques. The complexes exhibited octahedral geometries. Thermogravimetric (TGA and DSC) analysis is utilized to study the thermal properties of various compounds and reveal the presence of coordinated water molecules in the complexes. The multi-stage thermal decomposition mechanisms, where the thermal breakdown is ended by the formation of metal oxide as the final stable residue. The antioxidant activity of the ligand and its metal complexes was evaluated using the DPPH free radical scavenging assay and Gallic acid as a standard substance. Among the tested co
... Show MoreA simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec
... Show More