When laser light incident on biological tissue, it is either reflected from the
surface of the tissue (e.g. the skin) or scattered inside the tissue or absorbed .The laser light will be
absorbed by water, hemoglobin and melanin. Absorption is also highly dependent on wave-length of
laser radiation. The absorbed light is converted into kinetic energy leading to laser effect that when
appropriately applied can produce reaction ranging from incision, vaporization to coagulation. Aim of
the study: To evaluate the efficiency of diode Laser 810 ± 20nm in treatment of oral lesions. Methods:
6 patients (2 females and 4 males) with different oral lesions were treated in the hospital of specialized
surgeries by the use of diode laser 810 nm, the lesions were: Apthous, Lichen planus, Pyogenic
granuloma, Second stage of implant. Results: The result of the study depended mainly on the c l i n i c al
observation during operation and in the follow up period. The results show that there was no pain, no
bleeding, and no infection while the edema and necrosis at the operation site are present. Conclusion:
Laser can be used to perform haemostatic surgery, decrease rate of infection and reduce post operative
discomfort.
Many pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronidazole. The data
... Show MoreBackground: Staphylococcus spp. are widely distributed in nature and can cause nosocomial, skin infections, and foodborne illness, and it may lead to severe financial losses in birds by causing systemic infection in numerous organs. Aim: This study was conducted to determine the prevalence of Staphylococcus spp. in humans and birds in Baghdad city. Methods: Seventy-six oral cavity swabs were collected, including 41 from birds and 35 from breeders. All samples were examined by bacteriological methods and identified by using the VITEK technique, the samples were then further studied to test the ability of biofilm formation, and MDR factors and MAR index were tested with the use of seven antibiotics. Results: Among the 76 oral swa
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronid
... Show MoreObjective: The objective of the present study was to design and optimize oral fast dissolving film (OFDF) of practically insoluble drug lafutidine in order to enhance bioavailability and patient compliance especially for a geriatric and unconscious patient who are suffering from difficulty in swallowing.Methods: The films were prepared by a solvent casting method using low-grade hydroxyl propyl methyl cellulose (HPMC E5), polyvinyl alcohol (PVA), and sodium carboxymethyl cellulose (SCMC) as film forming polymers. Polyethylene glycol 400 (PEG400), propylene glycol (PG) and glycerin were used as a plasticizer to enhance the film forming properties of the polymer. Tween 80 (1% solution) and poloxamer407 were used as a surfactant, citri
... Show MoreBackground This study aimed to evaluate the efficacy of once-daily liraglutide as an add-on to oral antidiabetics (OADs) on glycemic control and body weight in obese patients with inadequately controlled type 2 diabetes (T2D). Methods A total of 27 obese T2D patients who received 7 months (0.6 mg/day for the first month, 1.2 mg/day for 3 months, and 1.8 mg/day for 3 months) of liraglutide treatment as an add-on to OADs were included. Data on body weight (kg), fasting plasma glucose (FPG, mg/dL), postprandial glucose (PPG, mg/dL), and HbA1c (%), were recorded. Results Liraglutide doses of 1.2 mg/day and 1.8 mg/day were associated with significant decreases in body weight (by 8.0% and 11.9%, respectively, p < 0.01 for each) and HbA1c (by 20.0
... Show MoreBackground: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to J
In the present work, the feasibility of formation near-ideal ohmic behavior of In/n-Si contact efficiently by 300 s duration Nd:YAG pulsed laser processing has been recognized. Several laser pulses energy densities have been used, and the optimal energy density that gives best results is obtained. Topography of the irradiated region was extensively discussed and supported with micrographic illustrations to determine the surface condition that can play the important role in the ohmic contact quality. I-V characteristics in the forward and reverse bias and barrier height measurements have been studied for different irradiated samples to determine the laser energy density that gives best ohmic behavior. Comparing the current results with
... Show MoreThe aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x
thirty adult NewZealand rabbits used in this study, they were divided in to two groups (control and treaded with Helium — Neon laser). A square skin flap done on the medial aspect of the auricle of both sides, a square piece of cartilage incised, pealed out from each auricle and fixed in the site of the other, then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated using a Helium —Neon laser with (5mw) power for (10 days) began after the operation directly, (3 rabbits) from each group used for collection of specimens for histopathological examination at the weeks (1,2,3,4, & 6) weeks post the operation .The results revealed Early invasion of the matrix with elastic fibers which continue to t
... Show MoreThis research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai