Preferred Language
Articles
/
ijl-108
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitation wavelength (λexcit.) = 669 nm). Five teeth were sent to
histopathological examination to confirm the efficacy of laser fluorescence technique for the
determination of actual carious lesion depth. The results are leading to the detection of carious lesions for
different depths. The deepest carious lesions revealed high fluorescence intensity. Based on these
findings; it was concluded that 650 nm CW diode laser (λexcit. = 669 nm 40 mW) is a suitable and a
reliable tool for caries diagnosis and depth assessment. Histopathological findings for the estimation of
actual carious lesion depth revealed a good correlation with that of laser fluorescence technique.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Effect of Operating Temperature on Performance of Obliquely Deposited Bi, Sb and Bi-Sb Semimetal Thin Film Laser Detectors
...Show More Authors

Obliquely deposited (70o) Bi, Sb, and Bi-Sb alloy thin films have been prepared by thermal
resistive technique. Structural properties of these films were studied using XRD. Their resistance and
voltage responsivity for Nd:YAG and CO2 laser pulses have been recorded as function of operating
temperature between 10 oC and 120 oC. It was found that the maximum responsivity for these detectors
can be obtained at 75 oC. On the other hand, the dependence of responsivity on the width of detectors was
investigated.

View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Laboratory Investigation on Roller Compaction Technique in Concrete Construction
...Show More Authors

Roller compacted concrete (RCC) is a concrete compacted by roller compaction. The concrete mixture in its unhardened state must support a roller while being compacted. The aim of this research work was to investigate the behavior and properties of roller compacted concrete when constructed in the laboratory using roller compactor manufactured in local market to simulate the field conditions. The roller compaction was conducts in three stages; each stage has different loading and number of passes of the roller. For the first stage, a load of (24) kg and (5) passes in each direction had been employed. For the second stage, a load of (104) kg and (10) passes in each direction were conducted. Finally, at the third stage, a load of (183) kg a

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Oct 06 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Image segmentation by using thresholding technique in two stages
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Coil migration during pressure-cooker technique for cerebral AVM
...Show More Authors

Introduction: In recent decades, the endovascular treatment of cerebral arteriovenous malformations (AVMs) has advanced. However, it still carries risks of unanticipated complications. Coil migration is a reported complication of aneurysmal coiling procedures. Herein, we report a case of early intraprocedural coil migration during pressure cooker technique embolization of right thalamic AVM, discussing the management and potential explanations. The literature showed no report of coil migration after the pressure cooker technique in the form of coil-augmented Onyx injection technique (CAIT). Case description: An otherwise healthy 26-year-old female suddenly developed a severe headache with no loss of consciousness. Computed tomograp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jan 05 2023
Journal Name
Mathematical Theory And Modeling
(Tc) Technique for Finding Optimal Solution To Transportation Problem
...Show More Authors

Given the importance of increasing economic openness transport companies’ face various issues arising at present time, this required importing different types of goods with different means of transport. Therefore, these companies pay great attention to reducing total costs of transporting commodities by using numbers means of transport methods from their sources to the destinations. The majority of private companies do not acquire the knowledge of using operations research methods, especially transport models, through which the total costs can be reduced, resulting in the importance and need to solve such a problem. This research presents a proposed method for the sum of Total Costs (Tc) of rows and columns, in order to arrive at the init

... Show More
Preview PDF
Publication Date
Tue Aug 02 2022
Journal Name
Karbala International Journal Of Modern Science
Performance Simulation for Adaptive Optics Technique Using OOMAO Toolbox
...Show More Authors

The Adaptive Optics technique has been developed to obtain the correction of atmospheric seeing. The purpose of this study is to use the MATLAB program to investigate the performance of an AO system with the most recent AO simulation tools, Objected-Oriented Matlab Adaptive Optics (OOMAO). This was achieved by studying the variables that impact image quality correction, such as observation wavelength bands, atmospheric parameters, telescope parameters, deformable mirror parameters, wavefront sensor parameters, and noise parameters. The results presented a detailed analysis of the factors that influence the image correction process as well as the impact of the AO components on that process

View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jul 01 2017
Journal Name
Journal Of King Saud University - Science
A semi-analytical iterative technique for solving chemistry problems
...Show More Authors

View Publication
Crossref (19)
Crossref
Publication Date
Sun Oct 31 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Image segmentation by using thresholding technique in two stages
...Show More Authors

Image segmentation can be defined as a cutting or segmenting process of the digital image into many useful points which are called segmentation, that includes image elements contribute with certain attributes different form Pixel that constitute other parts. Two phases were followed in image processing by the researcher in this paper. At the beginning, pre-processing image on images was made before the segmentation process through statistical confidence intervals that can be used for estimate of unknown remarks suggested by Acho & Buenestado in 2018. Then, the second phase includes image segmentation process by using "Bernsen's Thresholding Technique" in the first phase. The researcher drew a conclusion that in case of utilizing

... Show More
View Publication
Crossref
Publication Date
Sat Oct 01 2016
Journal Name
International Journal Of Pure And Apllied Mathematics
A SEMI ANALYTICAL ITERATIVE TECHNIQUE FOR SOLVING DUFFING EQUATIONS
...Show More Authors

View Publication
Crossref (13)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Urology Annals
Modified snodgrass hypospadias repair using the lembert suturing technique
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref