Preferred Language
Articles
/
ijl-108
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitation wavelength (λexcit.) = 669 nm). Five teeth were sent to
histopathological examination to confirm the efficacy of laser fluorescence technique for the
determination of actual carious lesion depth. The results are leading to the detection of carious lesions for
different depths. The deepest carious lesions revealed high fluorescence intensity. Based on these
findings; it was concluded that 650 nm CW diode laser (λexcit. = 669 nm 40 mW) is a suitable and a
reliable tool for caries diagnosis and depth assessment. Histopathological findings for the estimation of
actual carious lesion depth revealed a good correlation with that of laser fluorescence technique.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Detection of early occlusal caries of the first permanent molar using different techniques (An in vivo study)
...Show More Authors

Background: Molars and premolars are considered as the most vulnerable teeth of caries attack, which is related to the morphology of their occlusal surfaces along with the difficulty of plaque removal. different methods were used for early caries detection that provide sensitive, accurate preoperative diagnosis of caries depths to establish adequate preventive measures and avoid premature tooth treatment by restoration. The aim of the present study was to evaluate the clinical sensitivity and specificity rates of DIAGNOdent and visual inspection as opposed to the ICDAS for the detection of initial occlusal caries in noncavitated first permanent molars. Materials and Methods: This study examined 139 occlusal surface of the first permanent

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
The Use of Pulse Frequency Modulation Technique for Optical Video Communication System
...Show More Authors

An optical video communication system is designed and constructed using pulse frequency modulation (PFM) technique. In this work PFM pulses are generated at the transmitter using voltage control oscillator (VCO) of width 50 ns for each pulse. Double frequency, equal width and narrow pulses are produced in the receiver be for demodulation. The use of the frequency doubling technique in such a system results in a narrow transmission bandwidth (25 ns) and high receiver sensitivity.

View Publication Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Use the Six Sigma technique in a solutionProblems of work (analytical study)
...Show More Authors

The research Concentrates on modern Variable in the organizations that is 6 sigma. The field study is two of Iraqi industrial organizations, The first is state company of …………… , the other is the state company of ……

The problem of the research determines some questions and hypotheses, The data was Collected by question air, which contains 5 dimensions and (10) critical Successful factories  . 

The sample contains (42) who Works in that organizations. The points out many conclusions. The main of it, there is significant differences among the two organizations Then The research concluded with a number of important recommendations serve it's objectives .

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Compression-based Data Reduction Technique for IoT Sensor Networks
...Show More Authors

Energy savings are very common in IoT sensor networks because IoT sensor nodes operate with their own limited battery. The data transmission in the IoT sensor nodes is very costly and consume much of the energy while the energy usage for data processing is considerably lower. There are several energy-saving strategies and principles, mainly dedicated to reducing the transmission of data. Therefore, with minimizing data transfers in IoT sensor networks, can conserve a considerable amount of energy. In this research, a Compression-Based Data Reduction (CBDR) technique was suggested which works in the level of IoT sensor nodes. The CBDR includes two stages of compression, a lossy SAX Quantization stage which reduces the dynamic range of the

... Show More
View Publication Preview PDF
Scopus (42)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Structural, Optical, and Morphological Study of the Zinc Oxide Nano-Thin Films with Different Thickness Prepared by Pulsed Laser Deposition Technique
...Show More Authors

The goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi

... Show More
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Advances In Systems Science And Applications
A New Face Swap Detection Technique for Digital Images
...Show More Authors

View Publication
Scopus (1)
Scopus
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
A Case control study to determine Macrophage migration inhibitor, and N-telopeptides of type I bone collagen Levels in the sera of osteoporosis patients
...Show More Authors

This study focused on determining the markers of Macrophage migration inhibitor (MIF), as well as the N-telopeptides of type I bone collagen (NTX), and some other parameters (alkaline phosphatase (ALP), vitamin D (Vit D), calcium (Ca), phosphorus (P), and magnesium (Mg), and their correlation with other parameters in osteoporosis. One hundred ten subjects were involved in the current study. There were two groups of patients: group I (30) women with severe osteoporosis and group II (30) women with mild osteoporosis. For comparison, 50 apparently healthy individuals were included as a control. Serum levels of MIF, and NTX were significantly higher in groups I and II as compared to the control group, which indicate that these two parameters

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Study of Laser Propagation Parameters in the Underdense Plasma Region Using a Two Dimensional Simulation Code
...Show More Authors

The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for  = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.

View Publication Preview PDF
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Penicillin V from Simulated Fermentation Broth by Liquid-Liquid Membrane Technique
...Show More Authors

Liquid-liquid membrane extraction technique, pertraction, using three types of solvents (methyl isobutyl ketone, n-butyl acetate, and n-amyl acetate) was used for recovery of penicillin V from simulated fermentation broth under various operating conditions of pH value (4-6) for feed and (6-8) for receiver phase, time (0-40 min), and agitation speed (300-500 rpm) in a batch laboratory unit system. The optimum conditions for extraction were at pH of 4 for feed, and 8 for receiver phase, rotation speed of 500 rpm, time of 40 min, and solvent of MIBK as membrane, where more than 98% of penicillin was extracted. 

View Publication Preview PDF