The purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that extracted after two days after cavity preparation and B. 7 teeth that
extracted after twenty-one days after cavity preparation. Er: YAG Laser device emits radiation at
wavelength of 2940 nm in the infrared region. The laser irradiation was performed in a non-contact mode
with a focused beam of (energy density of 155985.96 mJ /cm2, energy of 600 mJ and a PRRs of 6 Hz for
enamel preparation) and (energy density=64994.151 mJ /cm2, energy = 250 mJ and a PRRs=4 Hz for
dentin preparation) with a spot diameter of 0.7mm at 12-15 mm distance and at right angle to the tooth
surface as possible. The histopathological results of the cavities prepared by Er: YAG Laser revealed the
early proliferation of the odontoblasts in the odontoblastic layer of the coronal part of the pulp which led
to the early formation of the reparative dentin in comparison to those prepared by conventional method.
It can be concluded that the use of the Er: YAG laser in class I cavity preparation has proved to be an
efficient technique in comparison to the conventional cavity preparation.
Titanium alloy surface properties have an essential role in the interaction of dental implants with bone, and alteration of the surface of the implant could improve osseointegration. This study was designed to investigate the effect of different heat treatment temperatures on titanium alloy surface properties for dental implants. The effect of different temperatures of heat treatment (750°C, 850°C, 950°C and 1050°C) were investigated on the surface topography, surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy. The disks were prepared from titanium alloy (Ti-6Al-4V) and the samples were divided into five groups depending on the different temperatures of heat treatment. The hea
... Show MorePotential health and environmental effects of nanoparticles need to be thoroughly assessed before their widespread commercialization. The present investigation was planned with the aims to determine the effects of gold nanoparticles (GNPs) on blast (BI) and mitotic (MI) indices of cultured lymphocytes. The results revealed that BI (50.3±2.3, 30.2±1.9, 10.5±0.7 and 0.0%, respectively) and MI (70.1±2.9, 20.4±1.1, 5.3±0.1 and 0.0%, respectively) showed a gradual decreased percentage as the concentration of GNPs was increased from 0.085 to 0.66 µg/mL, and the difference was significant compared to control culture (81.6±2.5 and 90.2±3.7%, respectively). A maximum inhibition of BI and MI was occurred at the concentration 0.66 µg/mL. In
... Show MoreThis study was aimed to explore the impact of social concepts about tribe, clan and women, on internal audit performance. These concepts are considered to be components of the organizational culture and performance of internal audit practice, with respect to the individual and collective performance within the institution. The study, furthermore, was intended to investigate and understand the role of the organizational culture of the tribal, clan and women components with regard to their role in society, in Qatar.
To achieve these objectives, the researcher followed the descriptive analytical approach, using a questionnaire directed to experts and staff working in the banking sector, with the view to test
... Show MoreThe duty of care is the essence of the error of negligence under the English legal system, and without it, responsibility for negligence cannot be judged, regardless of the extent of the damage incurred. contained in English law. In view of the importance of proving the existence of the duty of care on the defendant so that it is possible to judge his responsibility for negligence, the need arises to find a general principle to which the defendant is subject in order to decide whether he owes the plaintiff with the duty of care and therefore responsible for the negligence, and this is what we will explain in the research topic the study.
Abstract
The aim of the research is to demonstrate the role of uncertainty in adopting the general requirements for the strategic environmental assessment of service departments in Babil Governorate and the Environment Department. By focusing on a range of environmental problems, despite the efforts exerted to deal with the environme
... Show MoreAt a time of increasing human potential in the face of crises and risks through the use of technology on a large scale and steadily in various fields of life, and the vulnerability of business organizations as a result of mistakes. The failure of a sudden these errors or omissions or symptoms. Also, some crises occur outside the control of management, others caused by leakage of important information and sometimes secret may be a strategy or a new plan or new project occurs outside the organization to the opposite of what is planned. Therefore, the crisis management are critical to all organizations, because the active management of the crisis helps to ensure the continued prosperity of the organization. Here comes from the resea
... Show MorePotentiostatic polarization and weight loss methods have been used to investigate the corrosion behavior of carbon steel in sodium chloride solution at different concentrations (0.1, 0.4 and 0.6) M under the influence of temperatures ( 293, 298, 303, 308 and 313) K. The inhibition efficiency of the amoxicillin drug on carbon steel in 0.6 M NaCl has also been studied based on concentration and temperature. The corrosion rate showed that all salt concentrations ( NaCl solution) resulted in corrosion of carbon steel in varying ratio and 0.6 M of salt solution was the highest rate (50.46 g/m².d). The results also indicate that the rate of corrosion increases at a temperature of 313 K.. Potentiodynamic polarization studi
... Show More