Preferred Language
Articles
/
ijcpe-92
Extraction of Phenol from Aqueous Solutions Using Bulk ionic Liquid Membranes
...Show More Authors

Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl‐1‐methylimidazoliumhexafluorophosphate[Bmim][PF6],    

   1‐hexyl‐1‐methylimidazoliumhexafluorophosphate[Hmim][PF6], 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide[Bmpyr][NTf2], and 1-octyl-3-methyl imidazolium tetra fluoroborate[Omim][BF4].

   The distribution coefficients for phenol in these ionic liquids were measured at different pH values and found to be much larger than those in conventional solvents. Through the values of the distribution coefficients and the experiments that were conducted on bulk liquid membrane applying various types of prepared ionic liquids, 1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide was selected as the best ionic liquid which gave the highest extraction and stripping efficiencies.

   The effect of several parameters, namely, feed phase pH(2-12), feed concentration(100-1000 ppm), NaOH concentration(0-0.5M), temperature (20-50oC), feed to membrane volume ratio (200-400ml/80ml ionic liquid) and stirring speeds(75-125 rpm) on the performance of the choosen ionic liquid membrane were also studied.    

   The preliminary study showed that high phenol extraction and stripping efficiencies of 97% and 95% respectively were achieved by ionic liquid membrane with a minimum membrane loss which offers a better choice to organic membrane solvents.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Pharmaceutical Sciences And Research
Biosynthesis of zinc oxide nanoparticles by hot aqueous extract of Allium sativum plants
...Show More Authors

Current studies interested on the biosynthesis of zinc oxide nanoparticles (ZnO-NPs) using hot plants extracts of Allium sativum and characterization of them using: Atomic Force Microscopy (AFM), X-ray diffractions (XRD), Fourier Transform Infrared Spectroscopy (FT- IR), UV–visible spectral and Hot stage. The results found that all NPs are had nano-size. ZnO NPs was produced by four procedures using hot extract of Allium sativum. The average diameters were: 101.59 nm, 110.33 nm, 75.69 nm, 88.67 nm for first, second, third and fourth procedures respectively compared with 47.57 nm for standard NPs. The Roughness averages (Ra) were: 10.8 nm, 6.83 nm, 13.8 nm, 0.541 nm for first, second, third and fourth respectively. The Root mean square (Sq

... Show More
View Publication
Scopus (9)
Scopus
Publication Date
Tue Dec 31 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans: Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans
...Show More Authors

Six isolates of A. pullulans were collected from many sources including Hibiscus sabdariffa (Roselle), old Roofs of houses and bathroom surface that referred as Ap ros1, Ap or2, 3, 4 and Ap bs5, 6 respectively, all these isolates were identified based on morphological characteristics and nutritional physiology profiles, all were able to utilize various carbon and nitrogen sources such as glucose, xylose, sucrose, maltose, ammonium sulfate, ammonium nitrate and ammonium chloride, also they showed positive test for starch and amylase, while α-cellulose, ethanol, and methanol were could not be ass

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Tue Oct 07 2003
Journal Name
University Of Baghdad
A STUDY ON SOLVENT EXTRACTION OF HOLMIUM (III) WITH SUDAN BLACK B REAGENT (M.Sc. Thesis)
...Show More Authors

Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Oral Medicine And Oral Surgery
Reliability of two difficulty indexes in predicting the surgical extraction difficulty of impacted mandibular third molars
...Show More Authors

Introduction: The aim of this study was to compare the reliability and the agreement of the Pederson and Pernambuco difficulty indexes in predicting the surgical extraction difficulty of the impacted mandibular third molars. Materials and methods: A prospective observational cohort study was conducted on 83 patients who had undergone surgical removal of impacted mandibular third molar. The difficulty of extraction was determined preoperatively according to the total scores obtained from the Pederson and Pernambuco difficulty indexes, the operative difficulty was determined by the surgical technique and the duration of extraction. The accuracy of prediction of the surgical difficulty and

... Show More
View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Effect of Low Energy Laser on the Healing of Tooth Extraction Wound: (Histological Study in Rat)
...Show More Authors

Aims: This study was done to investigate the effect of low energy laser therapy on bone healing at the extraction site. Materials and methods:(24) male albino rats were exposed to the extraction procedure of the maxillary first molar on the first day of a seven day experiment and these animals were divided into two main groups; the control group and the laser group. The laser experiment involved using (Ga-As infrared diode laser) from optodent by directing the probe over the extraction site. The control group consisted of 4 rats, and the laser group was subdivided into 5 subgroups of 4 rats each. The laser dose was as follows: B1: a single dose of 5 minutes immediately after extraction.,

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Preconcentration and determination of Metformine Hydrochloride in different samples by cloud point extraction coupling with uv-visible spectrophotometry
...Show More Authors

This work was influenced the separation and preconcentration steps were carried out to determination of metformin (MET) in pharmaceutical preparations and human serum samples. Complex formation method and cloud-point extraction (CPE) coupling with UV-Visible spectrophotometry were used to investigated of study target.The results has showed the best optical characteristic for calibration curve and statistical data which were obtained under optimum conditions. The first method is based on the reaction of MET with nickel (II) in alkaline medium an absorption maximum ?)max) at 434nm. ''Beer's low'' is obeyed in the concentration range (10-100µg.ml-1) with molar absorptivity of 3.9x103 L.mol-1.cm-1.The limit of detection and quantitation valu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Engineering And Technology Journal
Study of the Diffusion Coefficient and Hardness for a Composite Material when Immersed in Different Solutions Polymer
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
ThermodynamicProperties of Nicotinicacid in Dilute HCl and inaqueous NaCl solutions at (293.15, 298.15, 303.15 and 308.15)K
...Show More Authors

Apparent molar volume, V?, and viscosity B-coefficient of nicotinc acid in water and in aqueous NaCl solutions have been determined from density and viscosity measurements at (293.15, 298.15, 303.15 and 308.15) K. The experimental density data were evaluated by Masson equation, and the derived, apparent molar volume at infinite dilution, Vo?, and the slope Sv, were interpreted in term of solute-solvent and solute- solute interactions. Transfer apparent molar volumes at infinite dilution of nicotinic acid from water to NaCl solutions at various temperatures have been calculated.The viscosity data have been analyzed using Jones-Dole equation, and the derived parameters, Jones-Dolecoefficient, B,and Falkenhagen coefficient,A, have been also in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Nonlienear Optics Quantum Optics
Narrow Emission Linewidth of Highly-Pure Silicon Nitride Nanoparticles in Different Dye Solutions as Random Gain Media
...Show More Authors

In this work, two different laser dye solutions were used to host highly-pure silicon nitride nanoparticles as scattering centers to fabricate random gain media. The laser dye was dissolved in three different solvents (ethanol, methanol and acetone) and the final results were obtained for methanol only. The silicon nitride nanoparticles were synthesized by dc reactive magnetron sputtering technique with average particle size of 35 nm. The random gain medium was made as a solid rod with high spectral efficiency and low production cost. Optical emission with narrow linewidth was detected at 532-534 nm as 9 mg of silicon nitride nanoparticles were added to the 10 -5 M dye solution. The FWHM of 0.3 and 3.52 nm was determined for Rhodamine B and

... Show More
View Publication