Preferred Language
Articles
/
ijcpe-899
Polyacrylamide Polymer Gel Systems for Conformance Control Technology: A Review
...Show More Authors

Low oil extraction and early high water production are caused in part by reservoir heterogeneity. Huge quantities of water production are prevalent issues that happen in older reservoirs. Polyacrylamide polymer gel systems have been frequently employed as plugging agents in heterogeneous reservoirs to regulate water output and increase sweep efficiency. Polyacrylamide polymer gel systems are classified into three classes depending on their composition and application conditions, which are in-situ monomer gel, in-situ polymer gel, and preformed particle gel (PPG).

   This paper gives a comprehensive review of PPG’s status, preparation, and mechanisms. Many sorts of PPGs are categorized, for example, millimeter-sized preformed particle gels, microgels, pH-sensitive cross-linked polymers, swelling polymer grains, and Bright Water®. In addition to this, the most important factors to consider while assessing gel performance, such as swelling capacity, PPG injectivity, and plugging efficiency, are studied carefully. Not only are the design considerations and field application of PPG mentioned, but also the advantages of PPG are demonstrated. Gels have been used in around 10,000 wells worldwide to reduce the   fractures permeability or super-high permeability channels during water and polymer floods.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparative Study of Pressure Losses and Hole Cleaning Efficiency of Water and Polymer solutions in Horizontal Wells
...Show More Authors

The main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Journal Of University Of Anbar For Pure Science (juaps)
Evaluation the Initial Values for Eccentric Anomaly for an Ellipse Orbit: Article Review
...Show More Authors

The equation of Kepler is used to solve different problems associated with celestial mechanics and the dynamics of the orbit. It is an exact explanation for the movement of any two bodies in space under the effect of gravity. This equation represents the body in space in terms of polar coordinates; thus, it can also specify the time required for the body to complete its period along the orbit around another body. This paper is a review for previously published papers related to solve Kepler’s equation and eccentric anomaly. It aims to collect and assess changed iterative initial values for eccentric anomaly for forty previous years. Those initial values are tested to select the finest one based on the number of iterations, as well as the

... Show More
View Publication
Publication Date
Mon Nov 06 2023
Journal Name
Eneurologicalsci
Dandy-Walker syndrome associated with a giant occipital meningocele: A case report and a literature review
...Show More Authors

HTH Ahmed Dheyaa Al-Obaidi,", Ali Tarik Abdulwahid', Mustafa Najah Al-Obaidi", Abeer Mundher Ali', eNeurologicalSci, 2023

View Publication
Scopus (2)
Scopus
Publication Date
Fri May 16 2025
Journal Name
Asean Journal Of Science And Engineering
Enhancing Predictive Maintenance in Energy Systems Using a Hybrid Kolmogorov-Arnold Network (KAN) with Short-Time Fourier Transform (STFT) Framework for Rotating Machinery
...Show More Authors

This study proposes a hybrid predictive maintenance framework that integrates the Kolmogorov-Arnold Network (KAN) with Short-Time Fourier Transform (STFT) for intelligent fault diagnosis in industrial rotating machinery. The method is designed to address challenges posed by non-linear and non-stationary vibration signals under varying operational conditions. Experimental validation using the FALEX multispecimen test bench demonstrated a high classification accuracy of 97.5%, outperforming traditional models such as SVM, Random Forest, and XGBoost. The approach maintained robust performance across dynamic load scenarios and noisy environments, with precision and recall exceeding 95%. Key contributions include a hardware-accelerated K

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
African Journal Of Hospitality, Tourism And Leisure
Employing marketing information systems for the success of small and medium enterprises: A field study of some Tourism and Travel companies in Baghdad
...Show More Authors

Scopus (6)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Advanced Pharmaceutical Technology & Research
Use of factorial design in formulation and evaluation of intrarectal in situ gel of sumatriptan
...Show More Authors

View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Study of R -molar ratio effect on the transformation of tetraethylorthosilicat precursor to gels in sol-gel technique
...Show More Authors

The effect of using different R -molar ratio under variable reaction conditions (acidic as well as basic environment and reaction temperature) have been studied. The overall experiments are driven with open and closed systems. The study shows that there is an optimum value for a minimum gelling time at R equal 2. The gelling time for all studied open system found to be shorter than in closed system. In acidic environment and when R value increased from 2 to 10, the gelling time of closed systems has increased four times than open systems at T=30 ?C and fourteen times when temperature reaction increased to 60 ?C. While in basic environment the influence of increasing R value was limited.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Health Follow up and Weight Control for Women with Osteoporosis in Baqubah City
...Show More Authors

Objective(s): assessment of  the health follow up and weight control for women with osteoporosis and find out the relationship between their health follow up and weight control and their socio-demographic characteristics.

Methodology: A descriptive study was conducted on women with osteoporosis for the period of September, 26th 2020 to Jun, 20th 2021. Non- probability (convenient) sample of (70) women with osteoporosis selected from (5) Private Clinics for Joints and Fractures in Baqubah City. A questionnaire was designed though extensive review of literatures and it consists of three parts: the first part includes women’s socio demographic characteristics, the second part inclu

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Investigation of Lipid Polymer Hybrid Nanocarriers for Oral Felodipine Delivery: Formulation, Method, In-vitro and Ex-vivo Evaluation
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Wed Nov 02 2022
Journal Name
Polymers
Ameliorating the Mechanical Parameters, Thermal Stability, and Wettability of Acrylic Polymer by Cement Filling for High-Efficiency Waterproofing
...Show More Authors

Acrylic polymer/cement nanocomposites in dark and light colors have been developed for coating floors and swimming pools. This work aims to emphasize the effect of cement filling on the mechanical parameters, thermal stability, and wettability of acrylic polymer. The preparation was carried out using the casting method from acrylic polymer coating solution, which was added to cement nanoparticles (65 nm) with weight concentrations of (0, 1, 2, 4, and 8 wt%) to achieve high-quality specifications and good adhesion. Maximum impact strength and Hardness shore A were observed at cement ratios of 2 wt% and 4 wt%, respectively. Changing the filling ratio has a significant effect on the strain of the nanocomposites. The contact angle was i

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref