Preferred Language
Articles
/
ijcpe-874
Constructed Wetland Units Filled with Waterworks Sludge for Remediating of Wastewater Contaminated with Congo Red Dye
...Show More Authors

The disposal of textile effluents to the surface water bodies represents the critical issue especially these effluents can have negative impacts on such bodies due to the presence of dyes in their composition. Biological remediation methods like constructed wetlands are more cost-effective and environmental friendly technique in comparison with traditional methods. The ability of vertical subsurface flow constructed wetlands units for treating of simulated wastewater polluted with Congo red dye has been studied in this work. The units were packed with waterworks sludge bed that either be unplanted or planted with Phragmites australis and Typha domingensis. The efficacy of present units was evaluated by monitoring of DO, Temperature, COD and dye concentration in the effluents under the variation of detention time (1-5 day) and dye concentration (10-40 mg/L). The maximum removal of dye and COD were 98 and 82% respectively for 10 mg/L of Congo red dye after five-day hydraulic retention time (HRT). The results have shown that the removal of COD and dye concentration significantly increased with higher contact time and lower dye concentration. The values of monitored parameters adopted to evaluate the wastewater quality (i.e. DO, COD and Congo red dye) are satisfied the requirements of irrigation water. The dye concentration variation in the effluent with contact time was formulated efficiently by Grau kinetic model. Functional groups (specified by FT-IR analysis) have a remarkable role in the entrapment of dye on the waterworks sludge bed.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Ecological Engineering
Modification of Electro-Fenton Process with Granular Activated Carbon for Phenol Degradation – Optimization by Response Surface Methodology
...Show More Authors

As a result of rapid industrialization and population development, toxic chemicals have been introduced into water systems in recent decades. Because of its excellent efficiency and simple design, the three-dimensional (3D) electro-Fenton method has been used for the treatment of wastewater. The goal of the current study is to explore the efficiency of phenol removal by the 3D electro-Fenton process, which is one of the advanced oxidation processes (AOPs). In the present work, the effect of the addition of granular activated carbon (GAC) particles to the electro-Fenton system as the third electrode would be investigated in the presence of graphite as the anode and nickel foam as the cathode, which is the source of electro-generated hydrogen

... Show More
View Publication
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Simulated Oily Wastewater by Ultrafiltration and Nanofiltration Processes
...Show More Authors

A study in the treatment and reuse of oily wastewater generated from the process of fuel oil treatment of gas turbine power plant was performed. The feasibility of using hollow fiber ultrafiltration (UF) membrane and nanofiltration (NF) membrane type polyamide thin-film composite in a pilot plant was investigated. Three different variables: pressure (0.5, 1, 1.5 and 2 bars), oil content (10, 20, 30 and 40 ppm), and temperature (15, 20, 30 and 40 ᵒC) were employed in the UF process while TDS was kept constant at 150 ppm. Four different variables: pressure (2, 3, 4 and 5 bar), oil content (2.5, 5, 7.5 and 10 ppm), total dissolved solids (TDS) (100, 200,300 and 400 ppm), and temperature (15, 20, 30 and 40 ᵒC) were manipulated with the h

... Show More
View Publication Preview PDF
Publication Date
Thu May 25 2023
Journal Name
Asian Journal Of Water, Environment And Pollution
Microbial Simultaneous Eradication from Wastewater of Sulphate and Heavy Metals
...Show More Authors

Hazardous materials, heavy metals, and organic toxins released into the environment have caused considerable harm to microbes, plants, animals, and humans. Wastewater is one of the most contaminated ecosystems due to heavy metals emitted mostly by human activity. Bioremediation of wastewater is an ecologically acceptable and cost-effective method of removing heavy metals from sewage; the general purpose of this study is to analyse the dependability of anaerobic sludge biomass in removing sulfur compounds and heavy metals from waste water. The anaerobic sludge biomass evaluated in this work was taken from a wastewater treatment plant (WWTP) in Al-Rustumiya, Baghdad, and grown in the mineral medium for anaerobic growth. In serum bottl

... Show More
View Publication
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Dec 23 2020
Journal Name
Iraqi Journal Of Agricultural Sciences
PHYTOREMEDIATION OF SYNTHETIC WASTEWATER CONTAINING COPPER BY USING NATIVE PLANT
...Show More Authors

This study was aimed to assess the efficiency of N.oleander to remove heavy metals such as Copper (Cu) from wastewater. A toxicity test was conducted outdoor for 65-day to estimate the ability of N.oleander to tolerate Cu in synthetic wastewater. Based on a previous range-finding test, five concentrations were used in this test (0, 50, 100, 300, 510 mg/l). The results showed that maximum values of removal efficiency was found 99.9% on day-49 for the treatment 50 mg/l. Minimum removal efficiency was 94% day-65 for the treatment of 510 mg/l. Water concentration was within the permissible limits of river conservation and were 0.164 at day-35 for the 50 mg/l treatment, decreased thereafter until the end of the observation, and 0.12 at d

... Show More
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Heliyon
Electrocoagulation treatment of high saline oily wastewater: evaluation and optimization
...Show More Authors

The present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters

... Show More
View Publication
Scopus (82)
Crossref (66)
Scopus Clarivate Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Flotation of Chromium Ions from Simulated Wastewater Using Air Microbubbles
...Show More Authors

   A microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/mi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Treatment of Dairy Wastewater by Electrocoagulation using Iron Filings Electrodes
...Show More Authors

This study investigated the treatment of dairy wastewater using the electrocoagulation method with iron filings as electrodes. The study dealt with real samples collected from local factory for dairy products in Baghdad. The Response Surface Methodology (RSM) was used to optimize five experimental variables at six levels for each variable, for estimating chemical oxygen demand (COD) removal efficiency. These variables were the distance between electrodes, detention time, dosage of NaCl as electrolyte, initial COD concentration, and current density. RSM was investigated the direct and complex interaction effects between parameters to estimate the optimum values. The respective optimum value was 1 cm for the distance between electrodes, (6

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Asian Journal Of Pharmaceutical And Clinical Research
HYDROGEN PEROXIDE LEVELS CORRELATE WITH SUPEROXIDE DISMUTASE IN IRAQI WOMEN WITH PREGNANCY-INDUCED HYPERTENSION
...Show More Authors

Objective: Pregnancy-induced hypertension (PIH) is a major pregnancy complication that leads to maternal mortality. Here, we have scrutinized the correlation between serum levels of hydrogen peroxide (H2O2) and superoxide dismutase (SOD) in PIH.Methods: Serum samples were collected from 80 Iraqi women (40 women with PIH as patients group, 20 normotensive pregnant women as a positive control, and 20 normotensive non-pregnant women as a negative control) all groups were diagnosed clinically.Results: Serum of H2O2 and SOD levels was measured for all studied groups. Results showed that there were no significant variances in age and gestational age distribution between all studied groups. Furthermore, result showed that the serum level o

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 01 2009
Journal Name
Arab Journal Of Gasteroenterology
Serum HCV-RNA levels in patients with chronic hepatitis C: correlation with histological features.
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Numerical investigation for Natural Convection in a square Enclosure with partially active thermal sides' wall
...Show More Authors

Three-dimensional cavity was investigated numerical in the current study filled with porous medium from a saturated fluid. The problem configuration consists of two insulated bottom and right wall and left vertical wall maintained at constant temperatures at variable locations, using two discretized heaters. The porous cavity fluid motion was represented by the momentum equation generalized model. The present investigation thermophysical parameters included the local thermal equilibrium condition. The isotherms and streamlines was used to examine energy transport and momentum. The meaning of changing parameters on the established average Nusselt number, temperature and velocity distribution are highlighted and discussed.

Scopus