Preferred Language
Articles
/
ijcpe-869
A Comparison Study for The Performance of Polyethersulfone Ultrafiltration Mixed Matrix Membranes in The Removal of Heavy Metal Ions from Aqueous Solutions
...Show More Authors

Polyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was found that this membrane has a higher ion exchange capacity than the other prepared membranes. Two isotherm models (Langmuir model, and Freundlich model) were employed in the analysis of the ion exchange equilibrium data. The experimental data best fitted the Langmuir model with R2 of 0.889 than the Freundlich model. 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of the Marginal Fitness of the Ceramic Crowns Fabricated with Different CAD/CAM Systems (An In Vitro Study)
...Show More Authors

Background: The marginal fit is the most characteristic that closely related to the longevity or success of a restoration, which is absolutely affected by the fabrication technique. The objective of present in vitro study was to evaluate the effect of four different CAD/CAM systems on the marginal fit of lithiµm disilicate all ceramic crowns. Materials and Methods: Adentoform tooth of a right mandibular first molar was prepared to receive all ceramic crown restoration with deep chamfer finishing line (1mm) and axial reduction convergence angle of 6 degree, dentoform model duplicated to have Nickel-Chromiµm master die. Thirty two stone dies produce from master die and distributed randomly in to four groups (8 dies for each group) accor

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Collegian
Behaviour change interventions to improve medication adherence in patients with cardiac disease: Protocol for a mixed methods study including a pilot randomised controlled trial
...Show More Authors

View Publication
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Evaluating The Performance of Public Companies in The Light of Financial Indicators Case study of the General Company for Drugs and Medical Supplies/ Samarra – Iraq For the period (2014-2019)
...Show More Authors

 

The research aimed to evaluate the financial performance of the Public Company for the manufacture of medicines and medical supplies / Samarra - Iraq to know the strengths and weaknesses that affect its performance, as well as to compare its performance in the years between (2017-2019), which are characterized by security stability with its performance in previous years (2014 -2016) which is characterized by security instability, to assess the extent of its ability to achieve growth in performance, by answering the main question, what is the evaluation of the performance of the Public Company for the manufacture of medicines and medical supplies / Samarra - Iraq in the light of financial indicators?

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Ions release from fixed orthodontic appliance in two different mouthwashes
...Show More Authors

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 08 2015
Journal Name
مجلة كلية التربية الاساسية القاجسية
Synthesis, Characterization, and Antibacterial Properties of mixed ligand Complexes of (L-Leucine and 8-hydroxyquinoline) with some metals Ions
...Show More Authors

Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Study of opacity broadening in spectral lines for helium like ions in aluminum plasma which produced by laser
...Show More Authors

A theoretical analysis studied was performed to study the opacity broadening of spectral lines emitted from aluminum plasma produced by Nd-YLF laser. The plasma density was in the range 1028-1026 )) m-3 with length of plasma about ?300) m) , the opacity was studied as function of plasma density & principle quantum number. The results show that the opacity broadening increases as plasma density increases & decreases with the spacing between energy levels of emission spectral line.

View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Design of a Simple Dust Removal System for a Solar Street Light System
...Show More Authors

      Dust and bird residue are problems impeding the operation of solar street lighting systems, especially in semi-desert areas, such as Iraq. The system in this paper was designed and developed locally using simple and inexpensive materials. The system runs automatically. It Connects to solar panels used in solar street lighting, and gets the required electricity from the same solar system. Solar panels are washed with dripping water in less than half a minute by this system. The cleaning period can also be controlled. It can also control, sensing the amount of dust the system operates. The impact of different types of falling dust on panels has also been studied. This was collected from different winds and studied their impact o

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Wed Sep 05 2018
Journal Name
Journal Of Education And Scientific Studies
Ligand-Mixed New of Evaluation Bacterial and Characterization ,Synthesis Some with phenanthroline1,10- and Dithiocarbamate Containing Complexes ions M
...Show More Authors

(phen) (L(M [formula general a with complexes ligand-mixed new of series A methods analyses different by characterised and synthesised been have ,ligand arysecond as phenanthroline1,10- = phen and ligand primary as dithiocarbamate-1-azolebenzoimid-H-1)sulfinyl)methyl)yl-”-2pyriden)trifluroethoxy2,2,2- “(-4-methyl3-(((2-Sodium = L,ZnIIandCdII,CuII,NiII,CoII= M where,Cl)]phen)(L(Pd [Cland]2)O2H( ligands to metal ,moments magnetic and ,elementalanalysis ,spectrum mass ,surementsmea conductivity ,analysis thermal ,spectroscopy Vis-UV ,IR-FT ,NMR-C,13 H1 such dithiocarbamate the with formed coordination anisobidentate that showed spectra IRFT The.)phen:dithiocarbamate:M) (1:1:1(be to found been has complexes all in ratio nitrogen th

... Show More
Publication Date
Thu Mar 21 2024
Journal Name
International Development Planning Review
THE EFFECT OF USING A DISABLING FORCE TRAINING TOOL ON WALKING PERFORMANCE: AN ANALYTICAL STUDY OF TIME AND STEP LENGTH IN THE 20 KM WALKING RACE EVENT FOR APPLICANTS
...Show More Authors

Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The Efficiency Of Physics Forceps In Comparison To The Conventional Dental Extraction Forceps: A randomized Clinical Trial
...Show More Authors

Background: Tooth extraction is one of the most commonly performed procedures in dentistry. It is usually a traumatic process often resulting in immediate destruction and loss of alveolar bone and surrounding soft tissues. Various instruments have been described to perform atraumatic extractions which can prevent damage to the paradental structures. The physics forceps is one of those innovations in dental extraction technologies that claim to provide an efficient means for atraumatic dental extractions. Materials and method: A randomized clinical trial was conducted to compare the physics forceps with the conventional forceps for the removal of 28 mandibular single rooted teeth under the following parameters: incidence of crown, root, b

... Show More
View Publication
Scopus (3)
Crossref (5)
Scopus Crossref