Preferred Language
Articles
/
ijcpe-868
Adsorption Isotherms and Isosteric Heat of Adsorption of Metal Organic Frameworks as Gas Storage for Liquefied Petroleum Gas Vehicle in Iraq
...Show More Authors

   This research provides a novel technique for using metal organic frameworks (HKUST-1) as a gas storage system for liquefied petroleum gas (LPG) in Iraqi vehicles to avoid the drawbacks of the currently employed method of LPG gas storage. A low-cost adsorbent called HKUST-1 was prepared and characterized in this research to investigate its ability for propane storage at different temperatures (25, 30, 35, and 40 oC) and pressures of (1-7) bar. HKUST-1 was made using a hydrothermal method and characterized using powder X-ray diffraction, BET surface area, scanning electron microscopic (SEM), and Fourier Transforms infrared spectroscopy (FTIR). The HKUST-1 was produced using a hydrothermal technique and possesses a high crystallinity of up to 97%, surface area 3400 m2/g, and pore volume 0.7 cm3/g.  The prepared adsorbent (HKUST-1) tested using volumetric method, the maximum adsorption capacity of propane was (10.499 mmol/g) at a temperature of 298K and a pressure of 7 bar.  Furthermore, adsorption isotherm study was conducted to understand the system equilibrium (i.e., the fitting with one of the known models Langmuir, Freundlich, and Temkin isotherm models). It was observed that the Freundlich isotherm model fitted well the experimental data. The Clausius-Clapeyron equation was used to determine the heat of adsorption, and the results revealed that the heat of adsorption increased as the propane adsorption capacity increased. The prepared HKUST-1, which has a large surface area and a high adsorption capacity, can be used as a major solution for gas storage for liquefied petroleum gas (LPG) in Iraqi vehicles.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Nov 26 2017
Journal Name
Journal Of Engineering
Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
...Show More Authors

Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in holding the oil industry infrastructure behind regarding maintenance and modernization. The primary concern in this work is the design and implementation of cathodic protection systems for the aboveground storage tanks farm in the oil industry.

Storage tank external base area and tank internal surface area are to be protected against corrosion using impressed current and sacrificial anode cathodic protection systems. Int

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 01 2022
Journal Name
International Journal Of Hydrogen Energy
Assessment of wettability and rock-fluid interfacial tension of caprock: Implications for hydrogen and carbon dioxide geo-storage
...Show More Authors

Scopus (175)
Crossref (172)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Using Alternative Cogeneration Plants in Iraqi Petroleum Industry
...Show More Authors

The present paper describes and analyses three proposed cogeneration plants include back pressure steam-turbine system, gas turbine system, diesel-engine system, and the present Dura refinery plant. Selected actual operating data are employed for analysis. The same amount of electrical and thermal product outputs is considered for all systems to facilitate comparisons. The theoretical analysis was done according to 1st and 2nd law of thermodynamic. The results demonstrate that exergy analysis is a useful tool in performance analysis of cogeneration systems and permits meaningful comparisons of different cogeneration systems based on their merits, also the result showed that the back pressure steam-turbine is more efficient than other pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Results In Engineering
Storage characteristics of solar thermal collector integrated with latent heat material: A comparative experimental study of two types of paraffin wax under varying incident radiation and different water flow rates
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Evaluation of Fatigue Behavior of Epoxy Coatings used for Potable Water Storage Tanks
...Show More Authors

In this paper, three types of epoxy-based coatings (Polyamide, pure Polyamine, and Polyamine reinforced by glass-flake) used as a lining for potable water tanks were studied using experimental and finite element methods. Tensile, impact, and fatigue tests were conducted on uncoated and coated AISI 316 stainless steel. The test results show that the applied epoxy based coating improves the mechanical properties, increases of fatigue crack resistance, and enhance the dynamic fracture toughness. The fatigue crack propagation is influenced by the compositions of epoxy coating, and the glass-flake improves the coating resistance to fatigue crack propagation compared to other types.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
The Relation between Bacterial and Heavy Metal Water Pollution and Blood Micronuclei as Biomarkers in the Tigris River Fish
...Show More Authors

The objective of this study is to evaluate the bacterial count and heavy metal concentration of river water on fish micronuclei. Fish and water samples are carried out in 1 May to 1 June 2013 from Tigris River. A total of fifty three fish sample are studied. The bacteriological quality of water showed that the total viable count is ranged from 150×103 to 352×103 cfu/ml and fecal coliform counts was 1250 cell/100ml during the study period. All the metals (Cu, Hg, Pb, and Zn) are within the normal limit, but Cd was slightly elevated in river water samples. The appearance of micronuclei in red blood cells of all fish species is detect , by recording a larger number of it, in ( Abu Alsomere , Hishne , Bannini Kaber al fam & Karkoor

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Wed Apr 30 2025
Journal Name
International Journal Of Environmental Impacts
Analysis of the Effect of Heavy Elements in Polluted Industrial Water and its Environmental Treatment: An Applied Study on the Gas Power Plant/ 1 (Central Region) in Southern Baghdad and its Discharge into the Tigris River
...Show More Authors

Water produced from power plants is one of the most important sources of water pollution, especially for areas like Baghdad, Contaminated industrial wastewater is a major environmental challenge due to the rapid growth of industries, leading to increased accumulation of harmful pollutants in water resources, the work is intended to study the impact of water generated from a power plant in the south on the level of heavy metals before and after the treatment process and after its discharge to the Tigris River. Objective is to determine the extent of heavy metals such as iron, copper, chromium, and zinc concentration in water extracted from various points and subsequently study the monthly variations of these elements with a view to assessmen

... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PC-Based Controller for Shell and Tube Heat Exchanger
...Show More Authors

PC-based controller is an approach to control systems with Real-Time parameters by controlling selected manipulating variable to accomplish the objectives. Shell and tube heat exchanger have been identified as process models that are inherently nonlinear and hard to control due to unavailability of the exact models’ descriptions. PC and analogue input output card will be used as the controller that controls the heat exchanger hot stream to the desired temperature.
The control methodology by using four speed pump as manipulating variable to control the temperature of the hot stream to cool to the desired temperature.
In this work, the dynamics of cross flow shell and tube heat exchanger is modeled from step changes in cold water f

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 14 2023
Journal Name
International Journal Of Information Technology & Decision Making
A Decision Modeling Approach for Data Acquisition Systems of the Vehicle Industry Based on Interval-Valued Linear Diophantine Fuzzy Set
...Show More Authors

Modeling data acquisition systems (DASs) can support the vehicle industry in the development and design of sophisticated driver assistance systems. Modeling DASs on the basis of multiple criteria is considered as a multicriteria decision-making (MCDM) problem. Although literature reviews have provided models for DASs, the issue of imprecise, unclear, and ambiguous information remains unresolved. Compared with existing MCDM methods, the robustness of the fuzzy decision by opinion score method II (FDOSM II) and fuzzy weighted with zero inconsistency II (FWZIC II) is demonstrated for modeling the DASs. However, these methods are implemented in an intuitionistic fuzzy set environment that restricts the ability of experts to provide mem

... Show More
View Publication
Scopus (3)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Baghdad Science Journal
Concentration of lead and the proportion of sedimentary organic matter , clay minerals , non-clay minerals and soil gradation , City of Nasiriyah , Southern Iraq
...Show More Authors

The present research included sampling and analysis of 41 soil samples , the samples cover various areas of Nasiriyah city (industrial,commercial,residential and agricultural ) to estimate pollution levels of lead element and determine the correlation between lead concentration and natural factors in soil which represent sedimentary organic matter content, granular gradient, clay minerals and non-clay minerals . The results of the current study showed that the average concentration of lead in the soil samples was 61.12 ppm , it was noticed an increase in the concentration of lead in environmental components in the area of this study especially in residential , industrial and commercial location and the impact of natural factors of the so

... Show More
View Publication Preview PDF
Crossref