This research provides a novel technique for using metal organic frameworks (HKUST-1) as a gas storage system for liquefied petroleum gas (LPG) in Iraqi vehicles to avoid the drawbacks of the currently employed method of LPG gas storage. A low-cost adsorbent called HKUST-1 was prepared and characterized in this research to investigate its ability for propane storage at different temperatures (25, 30, 35, and 40 oC) and pressures of (1-7) bar. HKUST-1 was made using a hydrothermal method and characterized using powder X-ray diffraction, BET surface area, scanning electron microscopic (SEM), and Fourier Transforms infrared spectroscopy (FTIR). The HKUST-1 was produced using a hydrothermal technique and possesses a high crystallinity of up to 97%, surface area 3400 m2/g, and pore volume 0.7 cm3/g. The prepared adsorbent (HKUST-1) tested using volumetric method, the maximum adsorption capacity of propane was (10.499 mmol/g) at a temperature of 298K and a pressure of 7 bar. Furthermore, adsorption isotherm study was conducted to understand the system equilibrium (i.e., the fitting with one of the known models Langmuir, Freundlich, and Temkin isotherm models). It was observed that the Freundlich isotherm model fitted well the experimental data. The Clausius-Clapeyron equation was used to determine the heat of adsorption, and the results revealed that the heat of adsorption increased as the propane adsorption capacity increased. The prepared HKUST-1, which has a large surface area and a high adsorption capacity, can be used as a major solution for gas storage for liquefied petroleum gas (LPG) in Iraqi vehicles.
This numerical study explores dynamic melting as an enhancement strategy to improve heat transfer in thermal energy storage (TES) systems utilizing phase change materials (PCM) with openings. Optimizing such systems is crucial for advancing renewable energy storage and integration. A 3D model simulates RT35 PCM flowing through a shell-and-tube heat exchanger annulus. The effects of varying PCM inlet slot diameter (2.5–7.5 mm), inlet pressure (1–40 Pa), and inlet/outlet port positioning on melting fraction and temperature distributions are computationally evaluated. Results show that increasing slot diameter from 2.5 mm to 7.5 mm reduces melting time by 13.6 % (from 550 to 475 min). Raising inlet pressure from 10 Pa to 40 Pa cuts melting
... Show MoreIn light of today's business world, who faces challenges and intense competition as a result of the rapid evolution of technical and informational, organizations had to respond to variables through the adoption of modern management techniques that reduce the effects of risks and activating the role of the internal control system in order to contribute to the early detection of risks and reduce the negative results expected .The research is to address the problem faced by organizations which still follow the traditional methods in the control activities, and the lack of knowledge of the management and their staff of the importance of the existence of risk management and internal control system takes into account these risks, and the limit
... Show MoreEmergency vehicle (EV) services save lives around the world. The necessary fast response of EVs requires minimising travel time. Preempting traffic signals can enable EVs to reach the desired location quickly. Most of the current research tries to decrease EV delays but neglects the resulting negative impacts of the preemption on other vehicles in the side roads. This paper proposes a dynamic preemption algorithm to control the traffic signal by adjusting some cycles to balance between the two critical goals: minimal delay for EVs with no stop, and a small additional delay to the vehicles on the side roads. This method is applicable to preempt traffic lights for EVs through an Intelli
A new and hybrid deep learning-based approach for diagnosing faults in electric vehicle (EV) drive motors is proposed in this article. This article presents a new and hybrid deep learning-based method of diagnosing faults in the drive motors of electric vehicles (EV). In contrast to standard CNNLSTM approaches that depend on SoftMax classification, the introduced framework combines a Random Forest (RF) classifier to enhance the generalization, interpretability, and robustness of fault prediction. Furthermore meant for use on edge computing equipment with IoT integration, the design allows for real-time monitoring in resource-limited settings. The introduced algorithm utilizes a Random Forest (RF) classifier for accurate fault classification
... Show More
... Show MoreConvection heat transfer in a horizontal channel provided with metal foam blocks of two numbers of pores per unit of length (10 and 40 PPI) and partially heated at a constant heat flux is experimentally investigated with air as the working fluid. A series of experiments have been carried out under steady state condition. The experimental investigations cover the Reynolds number range from 638 to 2168, heat fluxes varied from 453 to 4462 W/m2, and Darcy number 1.77x10-5, 3.95x10-6. The measured data were collected and analyzed. Results show that the wall temperatures at each heated section are affected by the imposed heat flux variation, Darcy number, and Reynolds number variation. The var
... Show MoreIn this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig
... Show More