The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 15
... Show MoreThe aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are withi
... Show MoreAntibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, Al-Kindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18
... Show MoreAntibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 co
... Show MoreNew membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0
... Show Moreطريقة سهلة وبسيطة ودقيقة لتقدير السبروفلوكساسين في وجود السيفاليكسين او العكس بالعكس في خليط منهما. طبقت الطريقة المقترحة بطريقة الاضافة القياسية لنقطة بنجاح في تقدير السبروفلوكساسين بوجود السيفاليكسين كمتداخل عند الاطوال الموجية 240-272.3 نانوميتر وبتراكيز مختلفة من السبروفلوكساسين 4-18 مايكروغرام . مل-1 وكذلك تقدير السيفاليكسين بوجود السبروفلوكساسين الذي يتداخل باطوال موجية 262-285.7 نانوميتر وبتراكيز مخ
... Show MoreA simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res
... Show MoreCharge transfer complex formation method has been applied for the spectrophotometric determination of erythromycin ethylsuccinate, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3- Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (10 - 110) μg.mL-1 with detection limit of 0.351μg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of eryth
... Show MoreA newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show More