Preferred Language
Articles
/
ijcpe-584
Study the Characteristic Performance of Trickling Filter for Pharmaceutical Waste Treatment
...Show More Authors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 01 2009
Journal Name
Journal Of Engineering
THE EFFECT OF OPERATING CONDITION FOR CUMENE CRACKING ON THE PERFORMANCE OF PREPARED HX - ZEOLITE CATALYST
...Show More Authors

The present study reports the effect of temperature and liquid hourly space velocity (LHSV) on the cumene cracking reaction rate and selectivity by using a laboratory continuous flow unit with fixed bed reactor operating at atmospheric pressure. The prepared HX zeolite was made from Iraqi kaolin with good crystallinity .The activity and selectivity of prepared HX-zeolite was compared with standard HY zeolite and HX zeolite catalysts in the temperature range of 673-823K and LHSV of 0.7-2.5 h-1 . It was found that the cumene conversion increases with increasing temperature and decreasing LHSV at 823K and LHSV of 0.7 h-1 the conversions 65.32, 42.88 and 59.42 mol% for HY, HX and prepared HX catalysts respectively and at LHSV of 2.5 h-1 and th

... Show More
Publication Date
Mon May 29 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
APPLICATION OF TQM REQUIREMENTS AND THEIR RELATIONSHIP TO ORGANIZATIONAL PERFORMANCE FROM THE POINT OF VIEW OF THE INTERNAL CUSTOMER/ COMPARATIVE STUDY.: APPLICATION OF TQM REQUIREMENTS AND THEIR RELATIONSHIP TO ORGANIZATIONAL PERFORMANCE FROM THE POINT OF VIEW OF THE INTERNAL CUSTOMER/ COMPARATIVE STUDY.
...Show More Authors

This study aims to Statement of the relationship between Total Quality Management philosophy and Organizational performance from the point of view of the internal customer. A comparison has been made between two companies, one of which applies the requirements of TQM well and the other does not apply these requirements as the (General Company for Electrical Industries/ Diyala) and (General Company for Electrical Industries/ Baghdad) to conduct the search, During the questionnaire prepared for this purpose and distributed to a sample of 30 employees in the General Company for Electric Industries/ Diyala and (20) employees of the General Company for Electrical Industries/ Baghdad. Their answers were analyzed using a simple correlation coef

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
FACTORY OF SORTING AND RECYCLING OF WASTE IN THE DISTRICT OF AL-MAHMOUDIYAH BETWEEN THE ECONOMIC AND ENVIRONMENTAL IMPACT: FACTORY OF SORTING AND RECYCLING OF WASTE IN THE DISTRICT OF AL-MAHMOUDIYAH BETWEEN THE ECONOMIC AND ENVIRONMENTAL IMPACT
...Show More Authors

The waste sorting and recycling plant in the district of al- Mahmudiya (Yusufiya) is the only laboratory in Baghdad governorate. It is the only one in Iraq that collects and recycles waste. After sorting, we have packages of raw materials (aluminum cans, glass bottles, plastic bottles, Nylon bags) as well as natural fertilizers (food residues and others) and a sanitary landfill with specifications that meet international standards; However, the absence of a structure for the management of the plant (manager, assistant manager, accountant, etc.) in addition to the non-supply of waste on a daily and continuous basis and the lack of cooperation of the Municipality of Baghdad with the management of the plant led to delay in the work

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 04 2020
Journal Name
Fibers
A Comparative Study of the Performance of Slender Reinforced Concrete Columns with Different Cross-Sectional Shapes
...Show More Authors

Most reinforced concrete (RC) structures are constructed with square/rectangular columns. The cross-section size of these types of columns is much larger than the thickness of their partitions. Therefore, parts of these columns are protruded out of the partitions. The emergence of columns edges out of the walls has some disadvantages. This limitation is difficult to be overcome with square or rectangular columns. To solve this problem, new types of RC columns called specially shaped reinforced concrete (SSRC) columns have been used as hidden columns. Besides, the use of SSRC columns provides many structural and architectural advantages as compared with rectangular columns. Therefore, this study was conducted to explain the structura

... Show More
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Feb 01 2026
Journal Name
Journal Of Engineering
Contribution of Fill-Concrete Compressive Strength on the Structural Performance of CFSST Columns: An Analytical Study
...Show More Authors

High-rise structures are a significant indication in contemporary urban improvement, mainly in areas characterized by accelerated urban growth and dense population. This type of building should be designed to withstand severe load conditions. Therefore, using composite structural elements in such structures is required for stronger and durable elements. This paper introduces a finite element analysis model for Concrete Filled Stainless Steel Tubular Columns (CFSST) of (100x100) mm cross-section and (1250) mm length to inspect the impact of concrete compressive strength on the response of (CFSST). The generated model was first evaluated through a comprehensive comparison with experimental research. Then, after the model was used to s

... Show More
View Publication
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Plant Archives
INVESTIGATING THE ABILITY TO USE NATURAL IRAQI MATERIAL "CRUSHED PORCELANITE ROCKS" IN GREYWATER FILTRATION, AND COMPARE IT WITH SAND FILTER
...Show More Authors

Publication Date
Wed Jul 01 2020
Journal Name
Plant Archives
Investigating the ability to use natural iraqi material ⇜crushed porcelanite rocks⇝ in greywater filtration, and compare it with sand filter
...Show More Authors

Scopus
Publication Date
Mon Nov 24 2025
Journal Name
Scientific Reports
A novel amide corrosion inhibitor derived from waste cooking oil for mild steel in hydrochloric acid
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 05 2024
Journal Name
Al-academy
Designs treatment of the internal spaces of pharmacies
...Show More Authors

The pharmacy is the face for the health buildings and hospitals, The linking professional relationships and functional, it is been from the important places that most people go it, so according to that we must format its interior design in form that suitable with the need of most people use it or work in it, and this the search goal, dashing from the search subject which to hide finding designer treatment for the pharmacies interior spaces, to give share in the functional improvement performance or aesthetic. We define the search goals to share in educate the pharmacist in the effect of interior design for improvement of interior environment, in addition to the search consider as designer trying add to the other trying the interior desig

... Show More
View Publication Preview PDF