Carbonized nonwoven nanofibers composite were fabricated using the electrospinning method of a polymeric solution composite followed by heat treatment including stabilization and calcination steps. The spun polymeric solution was a binary polymer mixture/organic solvent. In this study, two types of polymers (Polymethylmethacrylate (PMMA) and Polyethylene glycol (PEG)) were used separately as a copolymer with the base polymer (Polyacrylonitrile (PAN)) to prepare a binary polymer mixture in a mixing ratio of 50:50. The prepared precursor solutions were used to prepare the precursor nanofibers composite (PAN: PMMA) and (PAN: PEG). The fabricated precursors nonwoven fibers composite were stabilized and carbonized to produce carbon nonwoven nanofibers composite. The effect of the combined polymer type on the fiber size, fiber size distribution, and surface morphology of the prepared nonwoven nanofibers was studied. The nonwoven fibers orientation and surface morphology were characterized using field emission scanning electron microscope (FESEM). In addition, ImageJ software has been used to calculate the fiber size and fiber size distribution. Here, the obvious effect of the copolymer type on the surface morphology, fiber size, and fiber orientation has been demonstrated. Using a copolymer with PAN polymer led to increasing the fiber size. The carbonized nanofibers composite prepared using PEG polymer as a copolymer was more ordered fibers in comparison with the fiber orientation of carbon nanofibers based on pure PAN. In contrast of that, using PMMA as a copolymer resulted curly carbonized nonwoven nanofiber composite.
ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp
... Show MoreOptical spectrum of SN1987A at days 4 from the explosion and its light curve through the first 1444 days after the explosion have been studied. The hydrogen lines present in the spectrum confirms the general characteristics of Type II SN that occur due to core collapse of massive star. Each of the total mass ejected from the explosion and the amount of the total mass of Nickel radioactive isotopes that produced during the explosion as well as the initial velocity of the ejecta and the explosion energy have been determined and compared with different observed and calculated models obtained by different researchers and it’s found that, about 8.8 Mʘ of the progenitor envelope mass had been ejected during the explosion and it’s mixed with
... Show MoreThe increasing number of orphans and their organizations and institutes in our community makes it increasingly important to design and develop an expert system that supports decisions concerning orphans and their families. This system can be used by any orphans organization to facilitate its work.
The proposed work is designed to manage the Orphans and Families of Martyrs of Terrorism Expert System (OFMTES) by registry all information about all orphans to display mostly orphan deserves bill, data is entered for each orphan, and with each entry a counter is increased according to this input information; the output result represents the score for that orphan. Different orphans have different scores. Coloring is used to know the degree o
Methods: 112 placentae samples were investigated during the period from August 2007 to August 2008 under light microscopefor mother aged 15 - 45 years old.Results: It was found that normal placental shapes had no correlation to mother age, while abnormal shapes were found more inyoung age groups. The better placental measured parameters were found in mother age 20-24 years. The percentages ofabnormal umbilical cord insertion were very high compared to other studies. Babies’ gender had a correlation with theplacental thickness; male babies have thicker placentae than females. Male babies have longer umbilical cords with widerdiameter than females. Light microscope picture showed the chorionic villi with isolated fetal blood vessel were hig
... Show MoreSM ADAI, BN RASHID, Journal of Current Researches on Social Sciences, 2023
Purpose: As managers can lead a set of ways to improve internal communication in public organizations, and leadership can cultivate a common understanding of goals within the organization and share the vision in preparation for its way to better performance, the purpose of the research is to assess the type and strength of the relationship between internal communication and different forms of leadership. Theoretical framework: The study demonstrates how leaders in public organizations improve internal communication, related to employees' perceptions of public organizations' routines and performance. Design/methodology/approach: The study uses the ordinary least squares (OLS) and applied multiple regression A sa
... Show MoreThis study aimed to show the relationship between mental health and shyness for university students in Baghdad and Al – Mustansiria university which its subject was (200) students , ( 100) males and ( 100) females , Mental Health scale which is constructed by (Al – Janabi 1991) and developed by (Hassan 2006) was used for this aim ,The scale of shyness was built according to a questioner to the students and according to previous publications and studies .
Multiple regulation analysis step - wise was used for data analysis in order to identify the possibility to find single or couple indications for the independent variable (mental
... Show More