Preferred Language
Articles
/
ijcpe-473
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it was (99.4 kg/m3.s).

The adsorptive capacity of silica gel increases with decreasing hexane flow rate, as with increasing initial concentration of benzene in the mixture. The best adsorptive capacity of the imported silica gel (100 g of imported silica gel yielded 120 ml of benzene-free effluent) was achieved with the grade (1.18-5 mm) in size at a hexane flow rate 15 ml/min.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Al-nahrain Journal Of Science
Spectrophotometric Determination of Co(II) in Vitamin B12 Using2-(biphenyl-4-yl)-3-((2-(2,4-dinitrophenyl) hydrazono)methyl) imidazo [1,2-a]pyridine as Ligand by Flow Injection–Merging Zone Analysis
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0–180° Using a Single Solar Cell as a Detector
...Show More Authors

A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed May 19 2010
Journal Name
Journal Of College Of Science, University Of Babylon
H-Point Standard Addition Method for Simultaneous Determination of Cimetidine and Erythromycin Ethylsuccinate Drugs Using Bromothymol Blue as a Chromogenic Complexing Agent
...Show More Authors

The H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.

Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Qualitative and Quantitative Determination of Dapagliflozin Propanediol Monohydrate and Its Related Substances and Degradation Products Using LC-MS and Preparative Chromatography Methods
...Show More Authors

Dapagliflozin is a novel sodium-glucose cotransporter type 2 inhibitor. This work aims to develop a new
validated sensitive RP-HPLC coupled with a mass detector method for the determination of dapagliflozin, its
alpha isomer, and starting material in the presence of dapagliflozin major degradation products and an internal
standard (empagliflozin). The separation was achieved on BDS Hypersil column (length of 250mm, internal
diameter of 4.6 mm and 5-μm particle size) at a temperature of 35℃. Water and acetonitrile were used as
mobile phase A and B by gradient mode at a flow rate of 1 mL/min. A wavelength of 224nm was selected to
perform detection using a photo diode array detector. The method met the

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Innovative Food Science & Emerging Technologies
Non-thermal pasteurization of milk by elongated electrode moderate electrical field: Chemical and sensory analysis during cold storage and shelf-life determination
...Show More Authors

View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Micro Amount of Chromium (III) Using Sodium 4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate in the Presence of Surfactant, Study of Thermodynamic Functions and Their Analytical Applications
...Show More Authors

          Using sodium4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate (SDPIHN) as a chromogenic reagent in presence of non-ionic surfactant (Triton x-100) to estimate the chromium(III)  ion if the wavelength of this reagent 463 nm to form a dark greenish-brown complex in wavelength 586 nm at pH=10,the complex was stable for longer than 24 hours. Beer's low, molar absorptivity 0.244×104L.mol-1.cm-1, and Sandal's sensitivity 0.021 µg/cm2 are all observed in the concentration range 1-11 µg/mL. The limits of detection (LOD) and limit of quantification (LOQ), respectively, were 0.117 µg/mL and 0.385µg/mL. (mole ratio technique, job's method) were employed to

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Wed Feb 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
Advances In Physics Theories And Applications
Adsorption Study of Symmetrical Schiff Base Ligand 4,4’-[hydrazine-1,2-diylidenebis(methan-1-yl-1-ylidene) bis (2-methoxyphenol)] on Granulated Initiated Calcined Iraqi Montmorillonite via Columnar Method.
...Show More Authors

The adsorption ability of Iraqi initiated calcined granulated montmorillonite to adsorb Symmetrical Schiff Base Ligand 4,4’-[hydrazine-1, 2-diylidenebis (methan-1-yl-1-ylidene)) bis (2-methoxyphenol)] derived from condensation reaction of hydrazine hydrate and 4-hydroxy-3-methoxybenzaldehyde, from aqueous solutions has been investigated through columnar method.The ligand (H2L) adsorption found to be dependent on adsorbent dosage, initial concentration and contact time.All columnar experiments were carried out at three different pH values (5.5, 7and 8) using buffer solutions at flow rate of (3 drops/ min.),at room temperature (25±2)°C. The experimental isotherm data were analyzed using Langmuir, Freundlich and Temkin equations. The monol

... Show More
Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Chemical Engineering Communications
Microwave-assisted preparation of mesoporous-activated carbon from coconut (<i>Cocos nucifera</i>) leaf by H<sub>3</sub>PO<sub>4</sub>activation for methylene blue adsorption
...Show More Authors

View Publication
Scopus (122)
Crossref (114)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
...Show More Authors

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) b

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref