The determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be treated at the intake of KWTP and tends to be of less quality as it flows to south of city, where it is highly polluted at intake of RWTP.
The analysis of treated water quality parameters supplied by all water treatment plants indicated that most of these characteristics are within the Iraqi criteria and WHO guide lines except for the produced in RWTP.
RWTP exceeded the water quality standards which recommended by WHO particularly Bacterial Counts and Turbidity.
The analysis showed that all water treatment plants have little effect on the in removal of the most of inorganic chemicals pollutants, the increasing Level of Sulfate, Hardness, and Total Dissolved Solid in treated water could be related to the absence of any chemical treatment units in the conventional Baghdad water treatment works, and to the increasing of the concentration of these variables in river water.
The statistical analysis had indicated that the correlation coefficient between Turbidity and Total Coliform Bacteria in river water for KWTP, EWTP and KRWTP were good, and begin to increase at other water treatment plants reaching RWTP because the water quality of the river is deteriorated as the river flow downstream in Baghdad city.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
Advanced Oxidation of Antibiotics Polluted Water Using Titanium Dioxide in Solar Photocatalysis Reactor
...Show More Authors

The aim of this study was to investigate antibiotic amoxicillin removal from syn­thetic pharmaceutical wastewater. Titanium dioxide (TiO2) was used in photocatalysis treatment method under natural solar irradiation in a tubular reactor. The photocatalytic removal efficiency was evaluated by the reduction in amoxicillin concentration. The effects of antibiotics concentration, TiO2 dose, irradiation time and the effect of pH were studied. The optimum conditions were found to be irradiation time 5 hr, catalyst dosage 0.6 g/L, flow rate 1 L/min and pH 5. The photocatalytic treatment was able to destruct the amoxicillin in 5 hr and induced an amoxicillin reduction of about 10% with 141.8 kJ/L accumulate

... Show More
View Publication Preview PDF
Crossref (14)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Solving high sulfate content of sand used in concrete by magnetic water process
...Show More Authors

View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri May 18 2018
Journal Name
International Journal Of Simulation: Systems, Science & Technology
A Review of Advances in Pressurizer Response Research for Pressurized Water Reactor Systems
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Absorption of NO2 into Water and Nitric Acid Solutions in a Fixed Column
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Reducing the Water Hardness by Using Electromagnetic Polarization Method
...Show More Authors

Hard water does not pose a threat to human health but may cause precipitation of soap or results stone in the boilers. These reactions are caused by the high concentrations of Ca and Mg. In the industry they are undesirable because of higher fuel consumption for industrial use .Electromagnetic polarization water treatment is a method which can be used for increasing the precipitation of Ca 2+ and CO3 2- ions in hard water to form CaCO3 which leads to decrease the water hardness is research has been conducted by changing the number of coil turns and voltage of the system. The spectroscopy electron microscope was used for imaging the produced crystals. Results of the investigation indicated that

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
International Journal Of Nonlinear Analysis And Applications
Semi-parametric regression function estimation for environmental pollution with measurement error using artificial flower pollination algorithm
...Show More Authors

Artificial Intelligence Algorithms have been used in recent years in many scientific fields. We suggest employing flower pollination algorithm in the environmental field to find the best estimate of the semi-parametric regression function with measurement errors in the explanatory variables and the dependent variable, where measurement errors appear frequently in fields such as chemistry, biological sciences, medicine, and epidemiological studies, rather than an exact measurement. We estimate the regression function of the semi-parametric model by estimating the parametric model and estimating the non-parametric model, the parametric model is estimated by using an instrumental variables method (Wald method, Bartlett’s method, and Durbin

... Show More
Publication Date
Mon May 17 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The Relative Contribution of the Flexibility for the Hip Joint, the Angle of the Knees, and the Muscular Strength for Arms of Performance of the Front and Back Rolling Skills, Opening on the Floor Movement Mat
...Show More Authors

In order to improve the students’ performance level in some of the skills that are implemented on the mat device of ground movements, including the front and rear rolling, it is necessary to study the most important indicators that have a clear impact on the performance of those rolls. Among the objectives of the research: To identify the percentage of the contribution of flexibility of the hip joint, the angle of the knees and the muscular strength of the arms in the performance of the front and rear rolling skills, an opening of the research sample. The researchers used the descriptive method in the survey method for its suitability to the nature of the work, and the research community was represented by students of the third st

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Relevance of Budgeting Estimations for Control and Performance Evaluation in Adopting Kaizen: Hypothetical & Empirical Study
...Show More Authors

The kaizen is considered as one of the most important modern techniques which has been adopted by various economics entities especially manufacturing firms and its beginnings return to the middle of the earlier century that has been used by companies like Toshiba, Matsushita Electric, and Toyota. Which realized that these modern techniques would make a total change in the competitive environment and started qualifying and its staff in such away that enables them to go along with this unique environment. The continuous improvement (Kaizen) depends on the small continuous improvements in the product and the production operations during the production stage. Consequently, the research problem is represented in the improperly of the budg

... Show More
View Publication Preview PDF