The determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be treated at the intake of KWTP and tends to be of less quality as it flows to south of city, where it is highly polluted at intake of RWTP.
The analysis of treated water quality parameters supplied by all water treatment plants indicated that most of these characteristics are within the Iraqi criteria and WHO guide lines except for the produced in RWTP.
RWTP exceeded the water quality standards which recommended by WHO particularly Bacterial Counts and Turbidity.
The analysis showed that all water treatment plants have little effect on the in removal of the most of inorganic chemicals pollutants, the increasing Level of Sulfate, Hardness, and Total Dissolved Solid in treated water could be related to the absence of any chemical treatment units in the conventional Baghdad water treatment works, and to the increasing of the concentration of these variables in river water.
The statistical analysis had indicated that the correlation coefficient between Turbidity and Total Coliform Bacteria in river water for KWTP, EWTP and KRWTP were good, and begin to increase at other water treatment plants reaching RWTP because the water quality of the river is deteriorated as the river flow downstream in Baghdad city.
Urinary tract infection (UTI) is a considerable problem aecting the health of people each year. It is caused by various Gram-positive (G+ve) and Gram-negative (G-ve) pathogens. It is an important illness in the world aecting all age groups across their life span. Objectives: To identify the most common aerobic bacteria that cause UTIs and their antibiotic susceptibility and antimicrobial activity of plant extracts of the males' patients. Materials and methods: The study involved 35 midstream urine samples from the male students (University of Baghdad, Baghdad, Iraq) with suspicious symptoms of UTI, during the period from January-March 2018. Each urine sample was cultured rst on Mannitol Salt Agar and MacConkey agar plates to dierentiate
... Show MoreThe research topic (The Impact of the Compulsory Reserve on the Banks Credit-an applied research on a sample of Iraqi banks), was chosen on basis of the Iraqi private Banks attempts to increase their credit activities in hope to gain more profits.This coincided with the CBI aim to back the private banking market.It is thus apparent why the CBI issued its regulation to those banks to increase their capitals up to IDB250. On the other hand,the CBI acted as an obstacle in the way of increasing the private banks of their capitals,that is by implementing the quantitive monetary tool so called the compulsory reserve.This is why we intended to overlook at this contradictional problome
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
The present study was conducted to investigate effect of prey type on the relationship between age of females of Macrocyclops albidus and reproductive performance, which included each of mean number of nauplii, age at first brood, and age at first clutch. Results revealed that the correlation coefficient between the age at first brood and clutch and age of females fed on Artemia was significant P <0.05, being 0.65 and 0.81 respectively, while the correlations were not significant P>0.05 in females fed on mosquito larvae (Culex quinquefasciatus) and Paramecium nauplii. It was also found that the correlation coefficients between mean number of the nauplii and longevity in M. albidus were significant P<0.05 whereas, the correlations were not s
... Show MoreA recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (
This paper studied kinetics of flotation of emulsified paraffine in water in bubble column with sodium .dodecylsulphate as a collector agent. The effects of oil drops and air bubble diameters on the flotation rate constant were studied. The removal rate for each oil drop size was first order with respect to oil drop concentration. An experimental procedure permitting determination of the first order rate constants for removal due to bubble/drop interaction was developed, decreasing bubble diameter by adding NaCl and increasing oil drop diameter increased the rate constants. A comparison between the experimental and theoretical rate constants showed
... Show MoreThis study was conducted in fruit production lathe house of the Department Of Horticulture And Landscape Gardening, in the station (B), College Of Agricultural Engineering Sciences, University Of Baghdad, Al-Jaadria for 8 months, began from 1/3/2019 to 1/9/2019 to investigate the responses of C35 Citrus rootstock to influence of foliar spraying of zinc and irrigation with smoking-water at 2 years old saplings. the study included two factors, first factor was three concentrations of Zinc Element Z0(0 mg.l-1), Z1(50 mg.l-1) and Z2(75 mg.l-1) that sprays at leave. The second factor was watering saplings with smoke-water in three concentrations S0(0 vol.vol-1), S1(0.1 vol.vol-1) and (0.2vol.vol-1), and their interaction. The experiment was fact
... Show MoreKnowledge management contribute to the overall private university libraries to develop libraries for the purpose of creating human and technological resources by investing research and development, as well as education and training for life.
This study followed the methodology of the descriptive and historical pillars of knowledge management for the years 1990 to the present day in 2017, depending on statistical figures obtained by the researchers from the General Secretariat of the Central Library at the University of Baghdad, and the Human Resources Division, which specialized human resources training after 2004 (and before those years from 1982 until 2002, where the continuing education was committee of the fixed committees are wor