Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an important role in phosphorus removal. The removal efficiency increases with increasing pH, and the optimum dosage of CaCl2 was 60 mg/l. Alum demonstrated much better results in phosphorus removal than CaCl2.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
LEAD Removal from Industrial Wastewater by Electrocoagulation process
...Show More Authors

This investigation was carried out to study the treatment and recycling of wastewater in the Battery industry for an effluent containing lead ion. The reuse of such effluent can only be made possible by appropriate treatment method such as electro coagulation.
The electrochemical process, which uses a cell comprised aluminum electrode as anode and stainless steel electrode as cathode was applied to simulated wastewater containing lead ion in concentration 30 – 120 mg/l, at different operational conditions such as current density 0.4-1.2 mA/cm2, pH 6 -10 , and time 10 - 180 minute.
The results showed that the best operating conditions for complete lead removal (100%) at maximum concentration 120 mg/l was found to be 1.2 mA/cm2 cur

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 12 2020
Journal Name
Journal Of Material Cycles And Waste Management
New application of eco-friendly biosorbent giant reed for removal of reactive dyes from water followed by sustainable path for recycling the dyes-loaded sludge in concrete mixes
...Show More Authors

View Publication
Scopus (15)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Performance Evaluation of Al-Karkh Water Treatment Plant Using Model-driven and Data-Driven Models
...Show More Authors
Abstract<p>There is a great operational risk to control the day-to-day management in water treatment plants, so water companies are looking for solutions to predict how the treatment processes may be improved due to the increased pressure to remain competitive. This study focused on the mathematical modeling of water treatment processes with the primary motivation to provide tools that can be used to predict the performance of the treatment to enable better control of uncertainty and risk. This research included choosing the most important variables affecting quality standards using the correlation test. According to this test, it was found that the important parameters of raw water: Total Hardn</p> ... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Mon Apr 01 2024
Journal Name
South African Journal Of Chemical Engineering
Removal of COD from petroleum refinery wastewater by adsorption using activated carbon derived from avocado plant
...Show More Authors

View Publication
Scopus (14)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Wed Nov 05 2025
Journal Name
Irrigation And Drainage
Predicting Potential Salinity in River Water for Irrigation Water Purposes Using Integrative Machine Learning Models
...Show More Authors
ABSTRACT<p>Accurate prediction of river water quality parameters is essential for environmental protection and sustainable agricultural resource management. This study presents a novel framework for estimating potential salinity in river water in arid and semi‐arid regions by integrating a kernel extreme learning machine (KELM) with a boosted salp swarm algorithm based on differential evolution (KELM‐BSSADE). A dataset of 336 samples, including bicarbonate, calcium, pH, total dissolved solids and sodium adsorption ratio, was collected from the Idenak station in Iran and was used for the modelling. Results demonstrated that KELM‐BSSADE outperformed models such as deep random vector funct</p> ... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Biochemical And Cellular Archive
BIOETHANOL PRODUCTION FROM OLIVE SOLID WASTE USING SIMULTANEOUS SACCHARIFICATION AND FERMENTATION PROCESS
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri May 16 2025
Journal Name
Tikrit Journal Of Engineering Sciences
Comparative Study of Activated Carbon and Silver Nanoparticle-Loaded Activated Carbon Derived from Tea Waste for Removal of Tetracycline from Aqueous Solution
...Show More Authors

The present work elucidates the utilization of activated carbon (AC) and activated carbon loaded with silver nanoparticles (AgNPs-AC) to remove tetracycline (TC) from synthetically polluted water. The activated carbon was prepared from tea residue and loaded with silver nanoparticles. Scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and Brunauer-Emmett-Teller (BET) were used to characterize the activated carbon (AC) and silver nanoparticles-loaded activated carbon (AgNPs-AC). The impact of various parameters on the adsorption effectiveness of TC was examined. These variables were the initial adsorbate concentration (Co), solution acidity (pH), adsorption time (t), and dosag

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 04 2019
Journal Name
Drinking Water Engineering And Science Discussions
Bio-purification of drinking water by froth flotation
...Show More Authors

Abstract. The main technique for removing bacteria from water for various applications is chemical disinfection. However, this method has many disadvantages such as producing disinfectant by-products (DBPs), biofilm formation and either rendering the water unpotable (at high residual disinfection) or leaving a potential for lethal diseases such as Cholera (if the residual disinfection is too low). Recently, a process was developed for continuous removal of bacteria from water using the principle of froth flotation through compressed air only without any chemicals (Hassan, 2015). This work examines the extent to which chemical free froth flotation can purify drinking water. The experiments were carried out using two flotation columns

... Show More
View Publication
Crossref