In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FOPDT).
The conventional PI and PID control were studied and the tuning of control
parameters was found by Ziegler-Nichols reaction curve tuning method to find the
best values of proportional gain (Kc), integral time ( I) and derivative time ( D).
The conventional controller tuning is compared with IMC techniques in this work and
it was found that the Ziegler –Nichols controller provides the best control for the
disturbance and the worst for the set-point change, while the IMC controller results
show satisfactory set-point responses but sluggish disturbance responses because the
approximate FOPTD model has relatively small time delay.
Feedforward and feedforward combined with feedback control systems were used as
another strategy to compare with above strategies. Feedforward control provides a
better response to disturbance rejection than feedback control with a steady state
deviation (offset). Thus, a combined feedforward-feedback control system is preferred
in practice where feedforward control is used to reduce the effects of measurable
disturbances, while feedback trim compensates for inaccuracies in the process model,
measurement error, and unmeasured disturbances. Also the deviation (offset) in
feedforward control was eliminated.
The microbend sensor is designed to experience a light loss when force is applied to the sensor. The periodic microbends cause propagating light to couple into higher order modes, the existing higher order modes become unguided modes. Three models of deform cells are fabricated at (3, 5, 8) mm pitchand tested by using MMF and laser source at 850 nm. The maximum output power of (8, 5, 3)mm model is (3, 2.7, 2.55)nW respectively at applied force 5N and the minimum value is (1.9, 1.65, 1.5)nW respectively at 60N.The strain is calculated at different microbend cells ,and the best sensitivity of this sensor for cell 8mm is equal to 0.6nW/N.
Biodiversity, biological diversity, biological diversity, biological diversity, biological diversity, biological diversity, biological diversity (by developmental factors) environmental factors and environmental factors environmental factors and environmental factors and environmental factors Correlation between biology and the succession of geological and historical factors of living organisms and geological and historical factors to the site and what It is surrounded by natural and tourist attractions and the pursuit of scientific methods in order to advance the studies of biological diversity in the region .
This article aims to estimate the partially linear model by using two methods, which are the Wavelet and Kernel Smoothers. Simulation experiments are used to study the small sample behavior depending on different functions, sample sizes, and variances. Results explained that the wavelet smoother is the best depending on the mean average squares error criterion for all cases that used.
There many methods for estimation of permeability. In this Paper, permeability has been estimated by two methods. The conventional and modified methods are used to calculate flow zone indicator (FZI). The hydraulic flow unit (HU) was identified by FZI technique. This technique is effective in predicting the permeability in un-cored intervals/wells. HU is related with FZI and rock quality index (RQI). All available cores from 7 wells (Su -4, Su -5, Su -7, Su -8, Su -9, Su -12, and Su -14) were used to be database for HU classification. The plot of probability cumulative of FZI is used. The plot of core-derived probability FZI for both modified and conventional method which indicates 4 Hu (A, B, C and D) for Nahr Umr forma
... Show MoreTThe property of 134−140Neodymium nuclei have been studied in framework Interacting Boson Model (IBM) and a new method called New Empirical Formula (NEF). The energy positive parity bands of 134−140Nd have been calculated using (IBM) and (NEF) while the negative parity bands of 134−140Nd have been calculated using (NEF) only. The E-GOS curve as a function of the spin (I) has been drawn to determine the property of the positive parity yrast band. The parameters of the best fit to the measured data are determined. The reduced transition probabilities of these nuclei was calculated. The critical point has been determined for 140Nd isotope. The potential energy surfaces (PESs) to the IBM Hamiltonian have been obtained using the intrin
... Show MoreThis study aimed to identify the degree of use computers in administrative functions (planning, organization, controlling, and evaluation) among school leaders and assistants in public education schools in Sharoorah governorate ، as well as to identify obstacles of use computers in administrative functions from the perspective of school leaders and assistants male and female in public schools during the academic year 1439-1440, the study sample (66) school leaders and assistants, males (58), a and females (44), , and to answer the questions of the study, the researchers developed a questionnaire consisting of (60) items, has been verified sincerity and persistence, and data analysis was used frequencies, percentages an
... Show MoreLimitations of the conventional diagnostic techniques urged researchers to seek novel methods to predict, diagnose, and monitor periodontal disease. Use of the biomarkers available in oral fluids could be a revolutionary surrogate for the manual probing/diagnostic radiograph. Several salivary biomarkers have the potential to accurately discriminate periodontal health and disease. This study aimed to determine the diagnostic sensitivity and specificity of salivary interleukin (IL)‐17, receptor activator of nuclear factor‐κB ligand (RANKL), osteoprotegerin (OPG), RANKL/OPG for differentiating (1) periodontal health from disease and (2) stable a
In this paper, we focused on the investigated and studied the cold fusion reaction rate for D-D using the theory of Bose-Einstein condensation and depending on the quantum mechanics consideration. The quantum theory was based on the concept of single conventional of deuterons in Nickel-metal due to Bose-Einstein condensation, it has supplied a consistent description and explained of the experimental data. The analysis theory model has capable of explaining the physical behaviour of deuteron induced nuclear reactions in Nickel metals upon the five-star matter, it's the most expected for a quantitative predicted of the physical theory. Based on the Bose-Einstein condensation theorem formulation, we calculation the cold fusion reaction rate fo
... Show More