Preferred Language
Articles
/
ijcpe-296
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as column height, Freon R11 mass flow rate and initial temperature of water on the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness.

The obtained experimental results showed that the average percentage holdup increased with increasing in the process variables. The heat transfer rate increased clearly with increasing in mass flow rate of Freon R11 while it increased very little when column height and initial temperature of water increased, it increased two times when increase the mass flow rate from 1.8 to 5.4 kg/hr. The volumetric heat transfer coefficient was found to decrease with increasing in column height and initial temperature of water, while it was increased with increasing in mass flow rate of Freon R11. The effectiveness was found to increase (maximum 90%) with increasing in column height and decreasing in the mass flow rate of Freon R11 and initial temperature of water. A statistical analysis was performed to get general correlations for the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness as a function of the studied parameters.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Nanoparticles and Surfactant on Phase Inversion of Two Phases
...Show More Authors

In the present study, a pressure drop technique was used to identify the phase inversion point of oil-in-water to water-in-oil flows through a horizontal pipe and to study the effect of additives (nanoparticles, cationic surfactant and blend  nanoparticles-surfactant) on the critical dispersed volume fraction (phase inversion point). The measurements were carried  for mixture velocity ranges from 0.8 m/sec to 2.3 m/sec. The results showed that at low mixture velocity 0.8 and 1 m/sec there is no effect of additives and velocity on phase inversion point, while at high mixture velocities the phase inversion point for nanoparticles and blend (nanoparticles/surfactant) systems was delayed (postponed) to a higher value of the dispers

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Fabrication of Filters via Welding of Ceramic Grains by Glassy Phase
...Show More Authors

The method of powder technology has been utilized for fabrication of ceramic filters. Ceramic filters with interconnected porosity have been achieved via mixes of ceramic powders with addition of glass powders, therefore, interparticle glassy phase is introduced and act as a weld between the crystalline grains in a high porosity microstructure. Tow types of ceramic filters have been produced, the first with high silica content and the other is with high alumina content. Both physical and mechanical properties has been performed and discussed

View Publication Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
IMPLEMENTATION OF ROOT FINDING ALGORITHM OF MINIMUM PHASE FILTER USING VHDL
...Show More Authors

Root-finding is an oldest classical problem, which is still an important research topic, due to its impact on computational algebra and geometry. In communications systems, when the impulse response of the channel is minimum phase the state of equalization algorithm is reduced and the spectral efficiency will improved. To make the channel impulse response minimum phase the prefilter which is called minimum phase filter is used, the adaptation of the minimum phase filter need root finding algorithm. In this paper, the VHDL implementation of the root finding algorithm introduced by Clark and Hau is introduced.
VHDL program is used in the work, to find the roots of two channels and make them minimum phase, the obtained output results are

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The dropping of three zeroes from Iraqi dinar
...Show More Authors

           The purpose of this research is to explain the effect of the dropping of three zeroes from Iraqi dinar on the basic role of the dinar and derivative and dynamic in transaction of Iraqi economic. the importance of this research comes from the effect of this operation on the evaluation of the exchange between the individuals of Iraqi society and the other between the Iraqi individuals and the foreign whom use the Iraqi dinar as a tool for exchange also the effect of the operation on the reserves of the Iraqi dinar the results of this research are as the following:-

1-the operation of dropping of zeroes must be associated with increase of the sharing of economic sectors wi

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Annealing Effect on Some Optical Properties of Cr2O3 Thin Films Prepared by Spray Pyrolysis Technique
...Show More Authors

Cr2O3 thin films have been prepared by spray pyrolysis on a glass substrate. Absorbance and transmittance spectra were recorded in the wavelength range (300-900) nm before and after annealing. The effects of annealing temperature on absorption coefficient, refractive index, extinction coefficient, real and imaginary parts of dielectric constant and optical conductivity were expected. It was found that all these parameters increase as the annealing temperature increased to 550°C.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Mar 19 2021
Journal Name
Annals Of The Romanian Society For Cell Biology 25 (6), 10203-10208‏
Effect of Boron Spray and Pollination Methods on “Zahdi” Date Palm Yield and Fruits Quality‏
...Show More Authors

Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
Synthesis, characterization, and optical properties of copper oxide thin films obtained by spray pyrolysis deposition
...Show More Authors

     Copper oxide thin films were synthesized by using spray pyrolysis deposition technique, in the temperature around 400°C in atmosphere from alcoholic solutions. Copper (II) chloride as precursor and glass as a substrate. The textural and structural properties of the films were characterized by atomic force microscopy (AFM), X-ray diffraction (XRD). The average particle size determined from the AFM images ranged from 30 to 90 nm and the roughness average was equal to 9.3 nm. The XRD patterns revealed the formation of a polycrystalline hexagonal CuO. The absorption and transmission spectrum, band gap, film thickness was investigated. The films were tested as an

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
CFD Simulation of Air Flow Patterns in a Spray Dryer Fitted With a Rotary Disk
...Show More Authors

The air flow pattern in a co-current pilot plant spray dryer fitted with a rotary disk atomizer was determined experimentally and modelled numerically using Computational Fluid Dynamics (CFD) (ANSYS Fluent ) software. The CFD simulation used a three dimensions system, Reynolds-Average Navier-Stokes equations (RANS), closed via the RNG k −ε turbulence model. Measurements were carried out at a rotation of the atomizer (3000 rpm) and when there is no rotation using a drying air at 25 oC and  air velocity at the inlet of  5 m/s without swirl. The air flow pattern was predicted experimentally using cotton tufts and digital anemometer. The CFD simulation predicted a downward central flowing air core surrounded by a slow

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
Structural and optical properties of TiO2:NiO nanoparticles thin films prepare by chemical spray pyrolysis
...Show More Authors

The properties of structural and optical of pure and doped nano titanium dioxide (TiO2) films, prepared using chemical spray pyrolysis (CPS) technique, with different nanosize nickel oxide (NiO) concentrations in the range (3-9)wt% have been studied. X-Ray diffraction (XRD) technique where using to analysis the structure properties of the prepared thin films. The results revealed that the structure properties of TiO2 have polycrystalline structure with anatase phase. The parameters, energy gap, extinction coefficient, refractive index, real and imaginary parts were studied using absorbance and transmittance measurements from a computerized ultraviolet visible spectrophotometer (Shimadzu UV-1601 PC) in the wavelength

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Crossref