Preferred Language
Articles
/
ijcpe-296
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as column height, Freon R11 mass flow rate and initial temperature of water on the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness.

The obtained experimental results showed that the average percentage holdup increased with increasing in the process variables. The heat transfer rate increased clearly with increasing in mass flow rate of Freon R11 while it increased very little when column height and initial temperature of water increased, it increased two times when increase the mass flow rate from 1.8 to 5.4 kg/hr. The volumetric heat transfer coefficient was found to decrease with increasing in column height and initial temperature of water, while it was increased with increasing in mass flow rate of Freon R11. The effectiveness was found to increase (maximum 90%) with increasing in column height and decreasing in the mass flow rate of Freon R11 and initial temperature of water. A statistical analysis was performed to get general correlations for the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness as a function of the studied parameters.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 11 2023
Journal Name
Healthcare
Short-Term (4 Day) Effects of Oral Rinsing with Miswak and Green Tea on Gingival Crevicular Fluid Flow and IL-1β Levels: A Pilot Study
...Show More Authors

Despite the antiplaque effect of mouth-rinsing with a combination composed of miswak (Salvadora persica L.) and green tea (Camellia sinensis var. assamica) extracts, no data are available regarding its effect on gingival tissue at the molecular level. This pilot study aimed to assess the effect of oral rinsing with this combination on gingival crevicular fluid (GCF) flow and IL-1β levels. Ten subjects rinsed with either the combination, 0.12% chlorhexidine gluconate (CHX) or distilled water without toothbrushing for 4 days after receiving baseline polishing. GCF IL-1β concentration, influx, resting volume and plaque quantity were measured at baseline and after 4 days for each intervention. No significant differences in GCF flow or

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jun 03 2025
Journal Name
Sar Journal Of Pathology And Microbiology
The Relation between Tumor Infiltrating Lymphocyte and Classical Tumor Staging in Colorectal Carcinoma (Semi-Quantitative Study by Immun histochemistry in a Group of Iraqi Patients)
...Show More Authors

Inflammatory response had a role in cancer progression, presence of noticeable inflammation within the tumor and its margin may play an important prognostic role in colorectal carcinoma.

Preview PDF
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (25)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sat Nov 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship among bite force with facial dimensions and dental arches widths in a sample of Iraqi adults with Class I skeletal and dental relations
...Show More Authors

Background: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 08 2020
Journal Name
Biochem. Cell. Arch
SYNTHESIS AND SPECTROSCOPIC CHARACTERIZATION OF NEW HETEROCYCLIC COMPOUNDS DERIVATIED FROM 1-(4-AMINOPHENYL) ETHAN-1-ONEOXIME AS A STARTING MATERIAL WITH EVALUATE THEIR BIOLOGICAL ACTIVITY
...Show More Authors

ABSTRACT : This research involves the synthesis of five to seven heterocyclic compounds starting with Schiff’s bases which derived from oxime as a starting material. 1.3-oxazepine derivatives were prepared from adding different anhydrides to the Schiff bases, tetrazole and thiazolidinone derivatives synthesized from add sodium azide and thioglycolic acid to the same Schiff’s bases as a five members ring. Pyrimidine derivatives were prepared after the reaction of the azomethine group with acetyl chloride and then urea and thiourea to synthesis on derivatives contain the six members ring. Another step included identified and confirmed these compounds by FT- IR, 1HNMR, TLC and 13CNMR finally, step included the assay of biological activity

... Show More
Publication Date
Wed Jun 19 2019
Journal Name
Biochemical And Cellular Archives
SYNTHESIS, CHARACTERIZATION, STRUCTURAL, THERMAL, POM STUDIES, ANTIMICROBIAL AND DNA CLEAVAGE ACTIVITY OF A NEW SCHIFF BASE-AZO LIGAND AND ITS COMPLEXATION WITH SELECTED METAL IONS
...Show More Authors

SYNTHESIS, CHARACTERIZATION, STRUCTURAL, THERMAL, POM STUDIES, ANTIMICROBIAL AND DNA CLEAVAGE ACTIVITY OF A NEW SCHIFF BASE-AZO LIGAND AND ITS COMPLEXATION WITH SELECTED METAL IONS

Scopus (3)
Scopus
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Assessment <b></b>of Serum P53 Protein Level in Adult Patients with Acute Myeloid Leukemia in Correlation with Response to Treatment
...Show More Authors

Background: Acute myeloid leukemia (AML) is an adult leukemia characterized by rapid proliferation of undifferentiated myeloid precursors, leading to bone marrow (BM) failure and impaired erythropoiesis. The p53 tumor suppressor protein regulates cell division and inhibits tumor development by preventing cell proliferation of altered or damaged DNA. It orchestrates various cellular reactions, including cell cycle arrest, DNA repair, and antioxidant properties. Objectives: To investigate the relationship of P53 serum level with hematological findings, remission, and survival status in de novo AML patients. Methods: This is a cross-sectional study that enrolled 63 newly diagnosed de novo AML patients, and 15 sex- and age-matched healt

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Sustainable Materials And Technologies
Green approach for fabrication of graphene from polyethylene terephthalate (PET) bottle waste as reactive material for dyes removal from aqueous solution: Batch and continuous study
...Show More Authors

Scopus (39)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (3)
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref