Preferred Language
Articles
/
ijcpe-296
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as column height, Freon R11 mass flow rate and initial temperature of water on the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness.

The obtained experimental results showed that the average percentage holdup increased with increasing in the process variables. The heat transfer rate increased clearly with increasing in mass flow rate of Freon R11 while it increased very little when column height and initial temperature of water increased, it increased two times when increase the mass flow rate from 1.8 to 5.4 kg/hr. The volumetric heat transfer coefficient was found to decrease with increasing in column height and initial temperature of water, while it was increased with increasing in mass flow rate of Freon R11. The effectiveness was found to increase (maximum 90%) with increasing in column height and decreasing in the mass flow rate of Freon R11 and initial temperature of water. A statistical analysis was performed to get general correlations for the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness as a function of the studied parameters.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Ingénierie Des Systèmes D Information
Performance Evaluation of Multi-Organization E-Government Based on Hyperledger Fabric Blockchain Platform
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 20 2021
Journal Name
Baghdad Science Journal
Performance Evaluation of Intrusion Detection System using Selected Features and Machine Learning Classifiers
...Show More Authors

Some of the main challenges in developing an effective network-based intrusion detection system (IDS) include analyzing large network traffic volumes and realizing the decision boundaries between normal and abnormal behaviors. Deploying feature selection together with efficient classifiers in the detection system can overcome these problems.  Feature selection finds the most relevant features, thus reduces the dimensionality and complexity to analyze the network traffic.  Moreover, using the most relevant features to build the predictive model, reduces the complexity of the developed model, thus reducing the building classifier model time and consequently improves the detection performance.  In this study, two different sets of select

... Show More
View Publication Preview PDF
Scopus (29)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Mon Mar 15 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Staff Nurses’ performance at Primary Health Care Centers in Baghdad City
...Show More Authors

Objectives: This study aimed to evaluate the performance of staff nurses at primary health care centers in Baghdad city and to compare them with their demographic characteristics of age, gender and education.
Methodology: A descriptive design was carried out at Baghdad City’s primary health care centers from January 2nd 2019 to May 1st 2020. An instrument was developed for the purpose of the study. A non-probability, multi-stage purposive sample of (52) staff nurses was recruited from nurses working at primary health care centers in Baghdad City. The instrument is used to evaluate staff nurses’ performance which includes (62) items. These items are divided to (13) main domains related to evaluation of work quantity, work quality,

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 05 2023
Journal Name
Journal Of Engineering
Performance Evaluation of Small Scale Air-Conditioning System Using R22 and Alternative Refrigerants
...Show More Authors

A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperatur

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Photoluminescence Spectra From The Direct Energy Gap of a-SiQDs
...Show More Authors

View Publication
Crossref
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Engineering
REMOVAL OF DIRECT BLUE DYE IN TEXTILEWASTEWATER EFFLUENT BY ELECTROCOAGULATION
...Show More Authors

 Removal of direct blue dye by electrocoagulation method has been investigated using aluminum   electrode in a bench-scale electrochemical system. Current density, NaCl concentration,   electrocoagulation time, and dye concentration has been studied as effecting parameters in color   removal efficiency. Increasing of current density will increase the color removal efficiency and   energy consumption as well. While increasing NaCl concentration increase the color removal   efficiency but it decrease energy consumption. High dye concentration is needed for extra   electrocaogolation time to reach the same efficiency that obtained with low dye concentration .With   current applied 0.35 amps. and NaCl concentration of 2 g/l more

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Senserless Speed and Position of Direct Field Orientation Control Induction Motor Drive
...Show More Authors

Direct field-orientation Control (DFOC) of induction motor drives without mechanical speed sensors at the motor shaft has the attractions of low cost and high reliability. To replace the sensor, information on the rotor speed and position are extracted from measured stator currents and from voltages at motor terminals. In this paper presents direct field-orientation control (DFOC) with two type of kalman filter (complete order and reduced order extended kalman filter) to estimate flux, speed, torque and position. Simulated results show how good performance for reduced order extended kalman filter over that of complete  order extended kalman filter in tracking performance and reduced time of state estimation.

View Publication Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
NATURAL CONVECTION HEAT TRANSFER IN AN INCLINED CIRCULAR CYLINDER
...Show More Authors

Experiments were carried out to investigate natural convection heat transfer in an inclined uniformly heated circular cylinder . The effects of surface heat flux and angle of inclination on the temperature and local Nusselt number variations along the cylinder surface are discussed . The investigation covers heat flux range from 92 W/m² to 487 W/m², and angles of inclination 0° ( horizontal) , 30° , 60° and 90° (vertical) . Results show an increase in the natural convection as heat flux increases and as angle of inclination moves from vertical to horizontal position. An empirical equation of average Nusselt number as a function of Rayliegh number was deduced for each angle of inclination .

View Publication Preview PDF
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Numerical Study Of Heat Transfer In Cooling Passages Of Turbine Blade
...Show More Authors

As the temperature of combustion gases is higher than the melting temperature of the turbine materials, cooling of turbine parts in a gas turbine engine is necessary for safe operation. Cooling methods investigated in this computational study included cooling flow losses. Film-cooling is one typically used cooling method whereby coolant is supplied through holes passage, in present study the holes placed along the camber line of the blade. The subject of this paper is to evaluate the heat transfer that occur on the holes of blade through different
blowing coolant rates. The cases of this study were performed in a low speed wind tunnel with two tip gap at small and large (0.03 and 0.09cm) and multiple coolant flow rates through the fil

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jul 27 2023
Journal Name
Journal Of Optics
Spectroscopic analysis of zinc plasma produced by alternating and direct current jet
...Show More Authors

In this study, a system of nonthermal plasma that was operated under atmospheric pressure and was powered by argon gas was employed. The particular plasma properties are affected by changes in the Ar gas flow ranges from 0.5 to 2.5 l/min, product by stream of the plasma jet that is utilized. By using the aforementioned method generated from AC and DC. After placing Ar gas as the cathode, which represents the negative pole, flows toward the anode, which is represented by a tiny metal plate of Zn measuring 6 × 1 cm2 in size, with a submerged part of 4 cm2 long, with both types of current employed having a high voltage of 13.5 kV and the frequency of AC was 30 kHz, we measured these variable parameters. It has been shown that when argon f

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref