Preferred Language
Articles
/
ijcpe-296
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as column height, Freon R11 mass flow rate and initial temperature of water on the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness.

The obtained experimental results showed that the average percentage holdup increased with increasing in the process variables. The heat transfer rate increased clearly with increasing in mass flow rate of Freon R11 while it increased very little when column height and initial temperature of water increased, it increased two times when increase the mass flow rate from 1.8 to 5.4 kg/hr. The volumetric heat transfer coefficient was found to decrease with increasing in column height and initial temperature of water, while it was increased with increasing in mass flow rate of Freon R11. The effectiveness was found to increase (maximum 90%) with increasing in column height and decreasing in the mass flow rate of Freon R11 and initial temperature of water. A statistical analysis was performed to get general correlations for the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness as a function of the studied parameters.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 25 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and In-vitro Evaluation of Itraconazole Floating Microparticles
...Show More Authors

Itraconazole (ITZ) is an antifungal drug (BCSII) used for the treatment of local and systemic fungal infections. Furthermore, ITZ used as an antifungal prophylaxis for immunocompromised patients.

The objective of the study is to overcome the two problems of low and pH dependent solubility of ITZ by its preparation as floating microparticles.

Firstly, pH-dependent floating microparticles were prepared using oil in water solvent evaporation method, from which the best one (F7) selected as a best pH-dependent formula with composition of   ITZ (200mg),EC (800mg), HPMC 15cps (200mg) and safflower oil (2ml) .Then, F7 was compared with the selected Relatively pH-independent ITZ floating microparticles formula  wit

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Dec 13 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
The Evaluation of Nurses' Practices regarding Electronic Nursing Documentation
...Show More Authors

Objective: This study aims to evaluate nurses' practices regarding electronic nursing documentation

Methodology: 40 nurses have been chosen for a pre experimental sample using a non-probability (purposive) method between November 20, 2021, and March 1, 2023. The pretest and posttest comparisons included the same group that had been exposed to the software.

Results : table the nurses' practices toward electronic nursing documentation was described as poor and fair it means that nurses practices need to be improved and developed by an interventional program. there is no significant differences between age, gender and years of employment variables and nurses practices.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jun 19 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis, Characterization and Antibacterial Evaluation of Some Coumarin Derivatives
...Show More Authors

Coumarin derivatives have shown different biological activities, such as antifungal, antibacterial   antiinflammatory, and antioxidant activities, besides antibiotic resistance modulating effects, and anti-HIV, hepatoprotective, and antitumor effect. So, new coumarin derivatives (hydrazones and an amide) were synthesized through multisteps reactions. All the synthesized target compounds were characterized by FT-IR spectroscopy, 1HNMR analysis. The compounds then evaluated for their anti-bacterial activity by means of well-diffusion method against two gram-positive bacteria (Staphylococcus aureus, Streptococcus pneumoniae) and two gram-negative bacteria  (E.coli and Pseudomonas aeruginosa). The highest activity was demonstr

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (9)
Scopus Crossref
Publication Date
Sat Oct 04 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Synthesis and antimicrobial evaluation of new 1,3,4 - Thiadizole Derivatives
...Show More Authors

The amino thiadiazole [I] on treatment with aromatic aldehydes yielded Schiff bases [IIa-c], which cyclized to thiazolidinone [IIIa-c] derivatives by reaction with thioglycolic acid. Reaction of carbon disulfide and methyl iodide with [I] gavedithiomethyl [IV] which on treatment with o-phenylenediamine gave the condensed N-Imidazolythiadiazolylamine [V], However, reaction of [I] with phenylisocyanate and phenylisothiocyanate afforded the carbamideand carbothiamide derivatives [VI. VII] ac. The structure of these compounds was characterized from their melting point, FTIR spectroscopy and elementalanalysis

Publication Date
Sun Jan 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of the addition of silanized Nano titania fillers on some physical and mechanical properties of heat cured acrylic denture base materials
...Show More Authors

Background: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirement. The purpose of this study was to evaluate the effect of addition of 3% wt of treated (silanized) Titanium oxide Nano filler on some physical and mechanical properties of heat cured acrylic denture base material. Materials and methods: 100 specimens were constructed, 50 specimens were prepared from heat cure PMMA without additives (control) and 50 specimens were prepared from heat cure PMMA with the addition of TiO2 Nano fillers. Each group was divided into 5 sub groups according to the test performed which was mixed by probe ultra-sonication machine. Results: A highly

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 25 2026
Journal Name
Iraqi Journal Of Mechanical And Material Engineering
THE INFLUENCE OF FRICTION FACTOR ON THE COMBINED CONVECTIVE AND RADIATIVE HEAT TRANSFER IN A RECTANGULAR DUCT WITH INTERIOR CIRCULAR CORE
...Show More Authors

View Publication
Publication Date
Sat Apr 01 2017
Journal Name
Desalination
Heat transfer coefficients and yield analysis of a double-slope solar still hybrid with rubber scrapers: An experimental and theoretical study
...Show More Authors

View Publication
Scopus (48)
Crossref (43)
Scopus Clarivate Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation the effect of burning investment and black sand materials on the surface roughness of acrylic resin denture base
...Show More Authors

Objective: The aim of this study was to evaluate the effect of pumice, burning investment material
and black sand on the surface roughness of heat cure acrylic resin.
Methodology: Sixty specimens were prepared from pink heat cure acrylic resin, the specimens
where grouped into; 20 specimens which polished with pumice and water (control group); 20
specimens which polished with investment material (after burning it) and water; and 20 specimens
which polished with black sand and water. The average surface roughness of specimens after
polishing procedure had been determined by profilometer (surface roughness tester).
Results: Through the application of ANOVA and LSD tests, the result of this study showed that there
wa

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
Recent Technologies In Sustainable Materials Engineering
Evaluation of Tensile Strength and Durability of Microbial Cement Mortar
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Geotechnical Engineering And Sustainable Construction
Evaluation of Live Load Distribution Factors of a Highway Bridge
...Show More Authors

Scopus (1)
Scopus Crossref