The present work describes the adsorption of Ba2+ and Mg2+ions from aqueous solutions by activated alumina in single and binary system using batch adsorption. The effect of different parameters such as amount of alumina, concentration of metal ions, pH of solution, contact time and agitation speed on the adsorption process was studied. The optimum adsorbent dosage was found to be 0.5 g and 1.5 g for removal of Ba2+ and Mg2+, respectively. The optimum pH, contact time and agitation speed, were found to be pH 6, 2h and 300 rpm, respectively, for removal of both metal ions. The equilibrium data were analyzed by Langmuir and Freundlich isotherm models and the data fitted well to both isotherm modes as indicated by higher correlation of determination R2> 0.87 in both single and binary systems. Pore diffusion model for batch adsorption was used to predict the concentration decay curve for adsorption of Ba2+ and Mg2+ onto activated alumina. There was a good agreement between the experimental data and the predicted decay curves using pore diffusion model.
Background: Ear infections can manifest in many forms depending on site of infection whether external, middle or internal ear and the culprit pathogen whether viral, bacterial or fungal. Acute middle ear infections are usually accompanied by aural discharge. Objective: 1. To get an overview on the bacterial pathogens involved in ear infections. 2. To assess the antibiotic resistance of bacterial pathogens. Methods: A cross sectional study conducted in Al-Kindy Teaching Hospital / Baghdad /Iraq. Swabs taken from 225 patients suffering from aural discharge were tested for culture and sensitivity for the duration of two years 2018-2019. Aural discharge is cultured by inoculating it into blood, MacConkey agar, chocolate agars and Sabou
... Show MoreThis article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreMultiple myeloma is hematological disease produces many complications in the bone, kidney, neural and other complications. The study aims to measure serum biomolecules like fetuin-A and resistin and determined the possibility to use these biomarkers as disease predictor. blood samples were isolated from 58 patients and 24 sex and age-matched control, serum then isolated, and proper ELISA kit then used to a determined level of B2 microglobulin, resistin, and fetuin-A. The result demonstrated significant increase in B2 microglobulin, fetuin-A and resistin in patients compare to control (1.3470.714 vs. 0.9130.253), p = 0.000, (14.00310.352 vs. 9.2594.264), p= 0.005, (1.9673.595 vs. 0.6040.622), p = 0.009, respectively. These di
... Show MoreNefopam (N.F.) HCl is a non-narcotic centrally-acting, non-opioid benzoxazocine analgesic to relieve acute and chronic pain. It exhibits low bioavailability (about 36%) due to its first-pass degradation in the liver.
Intranasal administration has been used as a new route for targeting active brain sites and enhancing the bioavailability of N.F. HCl bypassing hepatic metabolism.
In situ gel of N.F. HCl was prepared by the cold method using different concentrations of Poloxamer 407, Poloxamer 188, HPMC K4M, Carbapol 934, and Hyaluronic acid polymers.
The results show that identification tests are superimposed with references, solubility study shows that N.F. HCl is suitable to be administered intranasally; Compatibi
... Show MoreThe paper presents research results of the vibration transmitted from the steering wheel of the
tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the
tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the
tractor was examined and adjusted following the producer’s recommendations. The vibration levels
were measured during the operation tillage at idling and at full load .The field was 3١٫٧ m above level
sea. Soil was treated at soil constant moisture (1٧-20 %) with depth of plowing (١٧ cm). During
operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level
on the steering whee
Flat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I), dual channel with a smooth absorber plate (model II), dual channel with perforating “V” corrugated absorber plate (model III), dual channel with internal attached wire mesh (model Ⅳ), and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ). The dual channel collector used for
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
The hydraulic behavior of the flow can be changed by using large-scale geometric roughness elements in open channels. This change can help in controlling erosions and sedimentations along the mainstream of the channel. Roughness elements can be large stone or concrete blocks placed at the channel's bed to impose more resistance in the bed. The geometry of the roughness elements, numbers used, and configuration are parameters that can affect the flow's hydraulic characteristics. In this paper, velocity distribution along the flume was theoretically investigated using a series of tests of T-shape roughness elements, fixed height, arranged in three different configurations, differ in the number of lines of roughness element
... Show MoreMultiple myeloma is hematological disease produces many complications in the bone, kidney, neural and other complications. The study aims to measure serum biomolecules like fetuin-A and resistin and determined the possibility to use these biomarkers as disease predictor. blood samples were isolated from 58 patients and 24 sex and age-matched control, serum then isolated, and proper ELISA kit then used to a determined level of B2 microglobulin, resistin, and fetuin-A. The result demonstrated significant increase in B2 microglobulin, fetuin-A and resistin in patients compare to control (1.3470.714 vs. 0.9130.253), p = 0.000, (14.00310.352 vs. 9.2594.264), p= 0.005, (1.9673.595 vs. 0.6040.622), p = 0.009, respectively. &
... Show MoreIn this research, rabbit femurs were implanted with CP Ti screws coated with a combination of CaCO3 and nanohydroxyapatite, and the effect on osseointegration was assessed using histological and histomorphometric examination at 2 and 6 weeks. CaCO3 and nanohydroxyapatite were combined with the EPD to coat the surfaces of the CP Ti screws. The femurs of five male rabbits were implanted with coated and uncoated implant screws. Healing time was divided into two groups (2 and 6 weeks). After 2 and 6 weeks of implantation, the histological examination revealed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis revealed an increase in the percentage of ne
... Show More