Preferred Language
Articles
/
ijcpe-282
Environmental Assessment of Polycyclic Aromatic Hydrocarbon Concentrations in Air at Thermal South Power Station of Baghdad
...Show More Authors

Sixteen polycyclic aromatic hydrocarbons (PAHs) concentrations were measured in aerosol samples collected for the period from April 2012 to February 2013 at thermal south power station of Baghdad. Fourty one aerosol sample were extracted with (1:1) dichloromethane and methanol using soxhlet for seventeen hour. The extraction solution was analyzed applying GC/MS. The PAH concentrations outside thermal south power station were higher than those inside it, and higher in summer season than in winter. Naphthalene, pyrene, Anthracene, Indeno [1, 2, 3-cd] pyrene and Phenanthrene were the most abundant PAHs detected in all points at the site sampling. The total polycyclic aromatic hydrocarbon (TPAH) and total suspended particles (TSP) concentrations were measured during the measurement period. For individual PAH compounds, the results showed a strong correlation with each other (0.998 - 0.77) at both sites.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Dietary Assessment for Meals of Nurseries Children in Baghdad City
...Show More Authors

The objective of this study was to assess the nutritional status of childs of nurseries in Baghdad city so that an early detection of malnutrition cases could be carried out. The results revealed that the daily consumption of food calories, protein, fat and carbohydrate were 1180.5 calories, 27.2gm, 38gm and 180gm, respectively, which were less than the RDA values and the percentages of these nutrients supplied by the food intake were 90.8, 83.7, 87.3 and 90.3%, respectively. It was also demonstrated that the highest percentages of stunting, underweight and wasting, which amounted to 32, 22.7 and 1.5%, respectively, were among those childs who obtained inadequate calories, while the percentages of the forementioned malnutrition cases amon

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jul 01 2025
Journal Name
Egyptian Journal Of Medical Microbiology
Assessment of Ochratoxin A among Healthy Individuals in Baghdad, Iraq
...Show More Authors

Background: Mycotoxins have a significant impact on population health worldwide. Ochratoxin is a common mycotoxin that can be detected in the serum of healthy people due to its prevalence in food. Researches on ochratoxin and its metabolites in biological fluids can help us better understand the toxin's biological impacts. Objective: The aim of this study was to investigate whether individuals in Baghdad, Iraq, were exposed to ochratoxin A. Methodology: Serum samples were obtained from 90 healthy persons (ages 14–40 years) and evaluated for ochratoxin A using the human Ochratoxin A ELISA Kit, an accurate, quantitative, and sensitive technique (limit of detection 0.34 ng/ml). Results: We detected Ochratoxin A in all serum samples, with a m

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Science
Applications of Camera Total Station System (CTSS) in the Construction Surveying
...Show More Authors

AZ Khalaf, M kassim Haidir, LK Jasim, Iraqi Journal of Science, 2012

View Publication
Publication Date
Sat Feb 28 2026
Journal Name
International Journal Of Design & Nature And Ecodynamics
Indoor Air Quality in Charcoal-Grilling Restaurants of Baghdad: Short-Term Monitoring of PM2.5, PM10, CO2, and CO
...Show More Authors

This study investigates the levels of gaseous and particulate pollutants (PM2.5, PM10, CO, and CO₂) emitted during charcoal-grilling activities in five selected restaurants in the Al-Karkh district of Baghdad, with a focus on their environmental and health implications. Developing countries, including Iraq, face severe pollution-related challenges exacerbated by inefficient combustion processes inherent to traditional cooking practices. Restaurants that rely on charcoal grilling are a significant source of both indoor and outdoor air pollution, posing acute and chronic health risks to workers and patrons. This research documented measured amounts of pollutants released from burning coal using two types of particulate matter (PM2.5; PM10)

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Measurements of Radon-222 and its Daughters Concentrations in Buildings of Department Physics in College of Sciences of Baghdad University
...Show More Authors

The present work aims to investigate approaches, measures and detection of indoor radon level in buildings of the department of physics in college of science of Baghdad University. CR-39 solid state nuclear track detectors were used to measure the radon concentrations inside the rooms, including five laboratories and five workplace rooms in ground and first storey of the department. The average radon concentration at first storey was found to be 43.1±13.2 Bq/m3 and 40.1±13.4 Bq/m3 at the ground storey. The highest level of radon concentration at the first storey in the radioactive sources store was 87.5±29 Bq/m3 while at the ground storey in room(2) was 70.2±24 Bq/m3 which is due to the existence radioactive sources in some selected

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 13 2024
Journal Name
Journal Of Engineering And Applied Science
Assessment of using different ozone-friendly R22 alternative refrigerants in residential air conditioners in a high-ambient temperature country
...Show More Authors
Abstract<p>The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor </p> ... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Prepare a plan for the Total Productive Maintenance in the light of the concurrent engineering A Field Study in AL-Askandria General Company Machanical Industries and AL-Musaib Electric Power Station
...Show More Authors

           Strives Total Productive Maintenance  to increase the overall effectiveness of the equipment through the early involvement in the design and manufacture of equipment productivity. It also operates in an environment of simultaneous engineering work on the synchronization of activities to take advantage of early information by maintenance engineers, design, operation, and that helps to reduce the faults and facilitate future maintenance tasks.

    Has adopted a search in the theoretical concept of the total maintenance productivity and concurrent engineering activities carried out during which the conjunction a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 22 2018
Journal Name
Environmental Toxicology And Chemistry
Fate, uptake, and distribution of nanoencapsulated pesticides in soil–earthworm systems and implications for environmental risk assessment
...Show More Authors
Abstract<sec><label></label><p>Nanopesticides are novel plant protection products offering numerous benefits. Because nanoparticles behave differently from dissolved chemicals, the environmental risks of these materials could differ from conventional pesticides. We used soil–earthworm systems to compare the fate and uptake of analytical‐grade bifenthrin to that of bifenthrin in traditional and nanoencapsulated formulations. Apparent sorption coefficients for bifenthrin were up to 3.8 times lower in the nano treatments than in the non‐nano treatments, whereas dissipation half‐lives of the nano treatments were up to 2 times longer. Earthworms in the nano treatments accumulated approximately 50% more b</p></sec> ... Show More
View Publication
Scopus (39)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of students' knowledge about environmental health in College of Health and Medical Technology: A Cross-Sectional study
...Show More Authors

Objective: the aim of this study is to determine the level of students' knowledge about the environmental health.
Methodology: The cross-sectional study was conducted at the College of Health and Medical Technology in Baghdad
city during the period from 1st march till 1st of July 2012. Data was collected by self-recording of a previously designed
questionnaire to obtain socio-demographic information such as (age, gender, department, year of grade).
Results: The highest rate of students were in the 2nd year followed by the 3rd year, highest rate of students had low
level of knowledge followed by intermediate level of knowledge, while lowest rate of students on had high level of
knowledge .Females had higher level of know

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well

... Show More
View Publication
Scopus (137)
Crossref (121)
Scopus Crossref