Preferred Language
Articles
/
ijcpe-252
Improving Treatment Performance of Dissolved Air Flotation System by Using Ionic Liquids as Surfactants
...Show More Authors

The effect of three ionic liquids viz., 1-hexyl-3-methylimidazolium tetrafluoroborate (ILE), 1-hexyl-3-metylimidazolium hexafluorophosphate (ILF) and 1-octyl-3-methylimidazolium tetrafluoroborate (ILG) when used as surfactants on the performance of dissolved air floatation (DAF) was investigated.

   Experiments were conducted at a temperature of 30-35 ºC, 10ppm ferric chloride as coagulant, 50% recycle ratio, pH 8, and 10 minutes treatment time  to find oil and grease (OG) and turbidity removal efficiencies at saturation pressure (2-6) bar.

ILs were used at concentration of 50 µl/liter of treated water in two positions in DAF system; the saturation vessel and the treatment tank. The performance using ILs in the saturation vessel were better than that in treatment tank because  ILs reduced the surface tension of water, which lead to an increase in the solubility of air in water and eventually increase the microbubble formation.  The OG removal efficiency using ILG as an efficient surfactant in saturation vessel was higher than that in the treatment tank and higher than other ILs (ILG>ILF>ILE). The removal efficiency reached about 90% at a saturation pressure of 5 bar, and 85% at 3 bar, which reduces the operation costs.  The treated water oil concentration at 3bar was 9.5 ppm, which meets the Iraqi pre-disposal regulatory limit.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Numerical Simulation of Thermal-Hydrodynamic Behavior within Solar Air Collector
...Show More Authors

Solar collectors, in general, are utilized to convert the solar energy into heat energy, where it is employed to generate electricity. The non-concentrating solar collector with a circular shape was adopted in the present study. Ambient air is heated under a translucent roof where buoyant air is drawn from outside periphery towards the collector center (tower base). The present study is aimed to predict and visualize the thermal-hydrodynamic behavior for airflow under inclined roof of the solar air collector, SAC. Three-dimensional of the SAC model using the re-normalization group, RNG, k−ε turbulence viscus model is simulated. The simulation was carried out by using ANSYS-FLUENT 14.5. The simulation

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
2021 4th International Conference On Energy Conservation And Efficiency (icece)
Finite Element Modeling Of Finned Double-Pass Solar Air Heaters
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Performance Evaluation of the Investment Projects during the Implementation Phase (Najaf province as a case study)
...Show More Authors

The construction project is a very complicated work by its nature and requires specialized knowledge to lead it to success. The construction project is complicated socially, technically and economically in its planning, management and implementation aspects due to the fact that it has many variables and multiple stakeholders in addition to being affected by the surrounding environment. Successful projects depend on three fundamental points which are cost-time, performance and specifications. The project stakeholder's objective to achieve best specifications and the cost-time frame stipulated in the contract.

The question is, was the optimum implementation accomplished? The provision for the success of the project

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Treatment of Petroleum Refinery Wastewater by Sono Fenton Process Utilizing the in-Situ Generated Hydrogen Peroxide
...Show More Authors

Combining ultrasonic irradiation and the Fenton process as a sono-Fenton process, the chemical oxygen demand (COD) in refinery wastewater was successfully eliminated using response surface methodology (RSM) with central composite design (CCD). The impact of two main influential operational parameters (iron dosage and reaction time) on the COD removal from wastewater generated by an Iraqi petroleum refinery facility was explored. Removal of 85.81% was attained under the optimal conditions of 21 minutes and 0.289 mM of  concentration. Additionally, the results revealed that the concentration of has the highest effect on the COD elimination, followed by reaction time. The high R2 value (96.40%) validated the strong fit of the mo

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of Acute Cutaneous Leishmaniasis by Oral Zinc Sulfate and Oral Ketocanazole Singly and in Combination
...Show More Authors

View Publication
Crossref (7)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
A new approach for the topical treatment of acne vulgaris by clindamycin HCL supported on kalion
...Show More Authors

Has been studied both processes Almetzaz and extortion of a substance Alklanda Maysan different amounts of Alcaúlan Guy 70% alcohol solution using the method when the wavelength

View Publication Preview PDF
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
Experimental Study and Analysis on Degradation of Oily Sludge from Process Equipment by Continuous Hybrid Treatment
...Show More Authors

It is well known that petroleum refineries are considered the largest generator of oily sludge which may cause serious threats to the environment if disposed of without treatment. Throughout the present research, it can be said that a hybrid process including ultrasonic treatment coupled with froth floatation has been shown as a green efficient treatment of oily sludge waste from the bottom of crude oil tanks in Al-Daura refinery and able to get high yield of base oil recovery which is 65% at the optimum operating conditions (treatment time = 30 min, ultrasonic wave amplitude = 60 micron, and (solvent: oily sludge) ratio = 4). Experimental results showed that 83% of the solvent used was recovered meanwhile the main water

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Effluent quality assessment of sewage treatment plant using principal component analysis and cluster analysis
...Show More Authors

Sewage water is a mixture of water and solids added to water for various uses, so it needs to be treated to meet local or global standards for environmentally friendly waste production. The present study aimed to analyze the new Maaymyrh sewage treatment plant's quality parameters statistically at Hilla city. The plant is designed to serve 500,000 populations, and it is operating on a biological treatment method (Activated Sludge Process) with an average wastewater inflow of 107,000m3/day. Wastewater data were collected daily by the Mayoralty of Hilla from November 2019 to June 2020 from the influent and effluent in the (STP) new in Maaymyrh for five water quality standards, such as (BOD5), (COD), (TSS), (TP)

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
A Competitive Study Using UV and Ozone with H2O2 in Treatment of Oily Wastewater
...Show More Authors

          In this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2011
Journal Name
Journal Of The Saudi Society Of Dermatology & Dermatologic Surgery
Treatment of pityriasis versicolor using 1% diclofenac gel and clotrimazole cream (comparative therapeutic study)
...Show More Authors

KE Sharquie, HM Al-Hamamy, AA Noaimi, IA Al-Shawi, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2011 - Cited by 9

View Publication