Preferred Language
Articles
/
ijcpe-236
Chromium (VI) Removal from Wastewater by Electrocoagulation Process Using Taguchi Method: Batch Experiments
...Show More Authors

Electrocoagulation is an electrochemical method for treatment of different types of wastewater  whereby sacrificial anodes corrode to release active coagulant (usually aluminium or iron cations) into solution, while simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation or settling. The Taguchi method was applied as an experimental design and to determine the best conditions for chromium (VI) removal from wastewater. Various parameters in a batch stirred tank by iron metal electrodes: pH, initial chromium concentration, current density, distance between electrodes and KCl concentration were investigated, and the results have been analyzed using signal-to-noise (S/N) ratio. It was found that the removal efficiency of chromium increased with  increasing current density and KCl concentration, and decreases with increasing initial chromium concentration and distance between electrodes, while pH shows peak performance curve. Experimental work have been performed for synthetic solutions and real industrial effluent. The results showed that the removal efficiency of synthetic solution is higher than industrial wastewater, the maximum removal for prepared solution is 91.72 %, while it was 73.54 % for industrial wastewater for the same conditions.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
With Solvent Extraction Method, and via new Organic Reagent 2-(Benzo thiazolyl azo)-4,5- Diphenyl Imidazole for Spectrophotometric Determination of Copper (II) in different Samples
...Show More Authors

The new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
A Spotlight on the Experience of E-learning as a Learning Method for the Undergraduate Pediatric Nursing Students in Iraq during the COVID-19 Pandemic
...Show More Authors

    The emergence of COVID-19 has resulted in an unprecedented escalation in different aspects of human activities, including medical education. Students and educators across academic institutions have confronted various challenges in following the guidelines of protection against the disease on one hand and accomplishing learning curricula on the other hand. In this short view, we presented our experience in implementing e-learning to the undergraduate nursing students during the present COVID-19 pandemic emphasizing the learning content, barriers, and feedback of students and educators. We hope that this view will trigger the preparedness of nursing faculties in Iraq to deal with this new modality of learning and improve it should t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 05 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Level of professional pressures during the use of e-learning teaching method among teachers of the Faculties of Physical Education and Sports Sciences in Baghdad
...Show More Authors

View Publication
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Revista Iberoamericana De PsicologÍa Del Ejercicio Y El Deporte Vol. 18 No 1 Pp. 117-121
THE EFFECT OF SPECIAL EXERCISES ACCORDING TO THE DIFFERENTIATED TEACHING METHOD ON MENTAL MOTIVATION AND LEARNING THE SKILLS OF BASKETBALL AND SHOOTING FOR FEMALE STUDENTS
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (31)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Quantitative Determination and Cytotoxic Effect of Oleanolic Acid from Olea europaea Leaves Extract Cultivated in Iraq
...Show More Authors

Since its first description as a cytotoxic agent, Olea europaea leaves extract gained significant popularity against human breast cancer, ethyl acetate extract of Olea europaea leaves obtained by acid hydrolysis method was evaluated in vitro as cytotoxic agent against new human breast cancer (AMJ13) cell line, using the MTT assay. One main pentacyclic triterpenoid; oleanolic acid, was isolated from leaves of Olea europaea by well-known two different methods, but not used for this compound before, the acidic hydrolysis method and basic acidic method. The presence of oleanolic acid was proved in both methods with qualitative and quantitative d

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Bioremediation of Soil Contaminated with 2,4-D Herbicide Using Bioslurry Reactor
...Show More Authors

Ex-situ bioremediation of 2,4-D herbicide-contaminated soil was studied using a slurry bioreactor operate at aerobic conditions. The performance of the slurry bioreactor was tested for three types of soil (sand, sandy loam and clay) contaminated with different concentration of 2,4-D, 200,300and500mg/kg soil. Sewage sludge was used as an inexpensive source of microorganisms which is available in large quantities in wastewater treatment plants. The results show that all biodegradation experiments demonstrated a significant decreases in 2,4-D concentration in the tested soils. The degradation efficiency in the slurry bioreactor decreases as the initial concentration of 2,4-D in the soils increases.A 100 % removal was achieved at initial con

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Jun 29 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Effect of adding the Flavonoids from Zizypus spina-christi leaves in redox indicators of the fat extracted from Cows, Sheeps bones and storage on defferent temperature and periods.: Effect of adding the Flavonoids from Zizypus spina-christi leaves in redox indicators of the fat extracted from Cows, Sheeps bones and storage on defferent temperature and periods.
...Show More Authors


Flavonoids were extracted from Zizyphus spina-christi leaves by Ethyl acetate after acid digested and used as antioxidant. The dried extract was added separately to each sample of fat extracted from hallow cow and sheep bones as follows: T1 cow fat, T2 control for cow fat, T3 sheep fat and T4 control for sheep fat (the control T2 and T4 reffered to samples without added antioxidant).
Samples were stored at -18, 5, 25 and 55 °C for 28 days. The storage trials were conducted at -18, 5 and 25 °C for 28 days for T1, T2, T3 and T4. The chemical indices examined initially and at the end of storage period. PVs was 1.46, 1.46, 1.8 and 1.8 meq/ Kg oil respectively, FFA values were 0.245, 0.245, 0.244 and 0.244% respectively and TBA va

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION: SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION
...Show More Authors

            A new, simple, rapid and sensitive spectrophotometric method for the determination of sulfamethoxazole in both pure form and pharmaceutical preparations has been reported.The adapted technique based on utilization 4-aminobenzene sulfonic acid as a new modern chromogenic through an oxidative coupling reaction with sulfamethoxazole and potassium iodate in basic media to form orange soluble dye product with absorption maxima at 490 nm. Subject to Beer's law in the range 2–32μg mL-1. The values of molarabsorption coefficient (ε) and correlation coefficient were found to be 9.118 × 103 and0.9999 respectively whereas the Sandels index was

... Show More
View Publication Preview PDF