Using Different Surfactants to Increase Oil Recovery of Rumaila Field (Experimental Work)
...Show More Authors

Enhanced oil recovery is used in many mature oil reservoirs to increase the oil recovery factor. Surfactant flooding has recently gained interest again. To create micro emulsions at the interface between crude oil and water, surfactant flooding is the injection of surfactants (and co-surfactants) into the reservoir, thus achieving very low interfacial tension, which consequently assists mobilize the trapped oil.

In this study a flooding system, which has been  manufactured and described at high pressure. The flooding processes included oil, water and surfactants. 15 core holders has been prepared at first stage of the experiment and  filled with washed sand grains 80-500 mm and then packing the sand to obtain sand packs samples for experiment. It was found that the best rate for water injection was 1.2 PV. Productively, while the optimum injection rate was 1.0 PV economically.

The study observed that the cost of water injection in secondary recovery increased 700% when PV injected increased from 1.0 PV to 8.0 PV, while the recovery increased only about 8% (58.77 – 66.7%).

The effects of  concentration, salinity and temperature is also explored by examined many values of each parameter according to surface tension by using capillary rise method. It was found that the optimum conditions for surfactant flooding for sodium dodecyl sulfate (SDS) 0.01 molar for concentration, 5500 P.P.M for salinity and 70 °C for temperatures. These conditions was used  to all kinds of surfactants that have been used in this study.

The study results indicated that the best surfactant in both productively and economically was SDS with maximum recovery about 90% for each secondary and tertiary recovery and the optimum injection volume for all surfactants 1.2 PV .

Another 12 Core holders with fixed pore volume were prepared for the second stage of the experiment. At this stage the pore volume was approximately constant and the variation included different values of SDS concentrations (0.1 and 0.001 Molar) and different values of salinity (1000 P.P.M and 3000 P.P.M) and temperature equal to  90 °C. Each value for concentration was experimented with the two values of salinity which in result obtaining four flooding conditions. Each condition was flooded by three injection rates (50, 120, 200 %). The results proved the results obtained from the first stage.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 20 2017
Journal Name
Mechanical Sciences
Comparative experimental investigation and gap flow simulation in electrical discharge drilling using new electrode geometry
...Show More Authors

Abstract. This study presents experimental and numerical investigation on the effectiveness of electrode geometry on flushing and debris removal in Electrical Discharge Drilling (EDD) process. A new electrode geometry, namely side-cut electrode, was designed and manufactured based on circular electrode geometry. Several drilling operations were performed on stainless steel 304 using rotary tubular electrodes with circular and side-cut geometries. Drilling performance was characterized by Material Removal Rate (MRR), Electrode Wear Rate (EWR), and Tool Wear Ratio (TWR). Dimensional features and surface quality of drilled holes were evaluated based on Overcut (OC), Hole Depth (HD), and Surface Roughness (SR). Three-dimensional

... Show More
View Publication
Scopus (7)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study on Double-Pass Solar Air Heater with and without using Phase Change Material
...Show More Authors

In this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant

... Show More
View Publication Preview PDF
Crossref (25)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering Science And Technology
EXPERIMENTAL STUDY ON CURVED COMPOSITE I-GIRDER BRIDGE SUBJECTED TO IRAQI LIVE LOADING FOR ROAD BRIDGES
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering Science And Technology
Experimental study on curved composite I-girder bridge subjected to Iraqi live loading for road bridges
...Show More Authors

Preview PDF
Scopus (4)
Scopus
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Analysis of the performance of a fiber optic sensor used to measure the intensity of the electric field
...Show More Authors

In this research was conducted to provide a product to analyze the performance sensor fiber optic used to measure and feel the intensity of the electric field results showed obtained that use sensor long gives reactive high electric field strength and a high value for allergic sensor, but that is at the expense of reducing the intensity of the electric field that is detected

View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Cleaner Waste Systems
Performance enhancement of natural asphalt using waste-derived modifiers: Sugarcane molasses and waste engine oil
...Show More Authors

The growing demand for sustainable and high-performance asphalt binders has prompted the exploration of waste-derived modifiers. This study investigates the performance enhancement of Natural Asphalt (NA) using Sugarcane Molasses (SM) and Waste Engine Oil (WEO). The modified blends were prepared by partially replacing 50 % NA with varying proportions of SM and WEO ranging from 10 % to 40 % of the total weight of NA. Comprehensive testing was conducted, including penetration, softening point, ductility, viscosity, Bending Beam Rheometer (BBR), Multiple Stress Creep Recovery (MSCR), Energy Dispersive X-ray Spectroscopy (EDX), Fourier Transform Infrared (FTIR) spectroscopy, and Scanning Electron Microscopy (SEM). The results demonstrated that

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Green Engineering
Eco-Friendly Enhancement of Fire Tube Boiler Control in Oil Factory Using Functional Block Diagram
...Show More Authors

This research is a continued efforts for a project on the fire tube boiler control for Al Rasheed edible oil factory. The aim is to enhance the control system with new integral control one. A functional blocks diagram (FBD) was built and simulated. With Schneider smart relays, FBD differs than ladder logic programming in which the PID option is active. An extensive work was done to understand the operation sequence, emergency shutdown, and faults causing the trips. A control program was designed to control logical sequence of operation. Furthermore temperature is controlled via cascade control with fuel and air controllers. The temperature controller output is send as remote set point to the fuel controller in a serial cascade manner. The f

... Show More
Scopus
Publication Date
Fri Dec 25 2015
Journal Name
مجلة اتحاد الجامعات العربية للدراسات والبحوث الهندسية
Smart Sensing for Variable Pressure of Oil Well Safety Valve Using Proportional Pressure Control valve
...Show More Authors

Protection of the oil pipelineswhich extracted from the wells was found to shut the well and prevent the leakage of oil when broken using safety valve. This valve is automatically activated by loss of pressure between the well and pipelines, which take the pressure, signal from hydraulic pressure sensor through pressure control valve which has constant or variable value but it is regulated manually. The manual regulatory process requires the presence of monitoring workers continuously near the wells which are always found in remote areas. In this paper, a smart system has been proposed that work with proportional pressure control valve and also electronic pressure sensor through Arduino controller, which is programmed in a way that satisfie

... Show More
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Estimation of Cutoff Values by Using Regression Lines Method in Mishrif Reservoir/ Missan oil Fields
...Show More Authors

Net pay is one of the most important parameters used in determining initial oil in place of a reservoir. It can be delineated through the using of limiting values of the petrophysical properties of the reservoir. Those limiting values are named as the cutoff. This paper provides an insight into the application of regression line method in estimating porosity, clay volume and water saturation cutoff values in Mishrif reservoir/ Missan oil fields. The study included 29 wells distributed in seven oilfields of Halfaya, Buzurgan, Dujaila, Noor, Fauqi, Amara and Kumait.

This study is carried out by applying two types of linear regressions: Least square and Reduce Major Axis Regression.

The Mishrif formation was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref