Preferred Language
Articles
/
ijcpe-1112
Flotation of Chromium Ions from Simulated Wastewater Using Air Microbubbles
...Show More Authors

   A microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/min), and the contact time (5, 10, 15, 20, 25, 30, and 35 min). The experimental results revealed that the highest removal efficiency (95%) was achieved in 20 min with a pH of 7, a flow rate of air 0.5 L/min, an SDS surfactant concentration of 15 mg/L, and a pollutant concentration of 30 mg/L at a sampling port height of 30 cm. The use of microbubbles in comparison to normal bubbles, resulted in a 56% improvement of the removal efficiency. The flotation process follows a first-order kinetics.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 06 2020
Journal Name
Egyptian Journal Of Chemistry
Treatment of petroleum refinery wastewater by electro-Fenton process using porous graphite electrodes
...Show More Authors

View Publication
Scopus (30)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrocoagulation of phenol for wastewater treatment
...Show More Authors

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Electrocoagulation for Treatment of Simulated Blowdown Water Of Cooling Tower
...Show More Authors

This study investigates the results of electrocoagulation (EC) using aluminum (Al) electrodes as anode and stainless steel (grade 316) as a cathode for removing silica, calcium, and magnesium ions from simulated cooling tower blowdown waters. The simulated water contains (50 mg/l silica, 508 mg/l calcium, and 292 mg/l magnesium). The influence of different experimental parameters, such as current density (0.5, 1, and 2 mA/cm2), initial pH(5,7, and 10), the temperature of the simulated solution(250C and 35 0C), and electrolysis time was studied. The highest removal efficiency of 80.183%, 99.21%, and 98.06% for calcium, silica, and magnesium ions, respectively, were obtained at a current de

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Optical characteristics of simulated design of parabolic trough solar concentrator
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Mathematical Problems In Engineering
Enhanced Simulated Annealing for Solving Aggregate Production Planning
...Show More Authors

Simulated annealing (SA) has been an effective means that can address difficulties related to optimization problems. is now a common discipline for research with several productive applications such as production planning. Due to the fact that aggregate production planning (APP) is one of the most considerable problems in production planning, in this paper, we present multi-objective linear programming model for APP and optimized by . During the course of optimizing for the APP problem, it uncovered that the capability of was inadequate and its performance was substandard, particularly for a sizable controlled problem with many decision variables and plenty of constraints. Since this algorithm works sequentially then the current state wi

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Experimental study for the properties of Fe3O4 dusty plasma using the air in vacuum chamber system
...Show More Authors

In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 30 2024
Journal Name
Al-qadisiyah Journal For Engineering Sciences
Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf
...Show More Authors

Air-conditioning systems (ACs) are essential in hot and humid climates to ensure acceptable ambient air quality as well as thermal comfort for buildings users. It is essential to improve refrigeration system performance without increasing the effects of global warming potential (GWP) and ozone depletion potential (ODP). The main objective of this study is to evaluate the performance of an air conditioning system that operates with a liquid suction heat exchanger (LSHX) through implementing refrigerants with zero OPD and low GWP (i.e., R134a and R1234yf). Liquid suction heat exchanger (LSHX) was added to an automobile air conditioning system (AACS).When Liquid suction heat exchanger was added to the cycle, primary results indicated t

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Apr 12 2017
Journal Name
Journal Of Engineering
Cultivation of Chlorella Vulgaris Using Airlift Photobioreactor Sparged with 5%CO2-Air as a Biofixing Process
...Show More Authors

The present paper addresses cultivation of Chlorella vulgaris microalgae using airlift photobioreactor that sparged with 5% CO2/air. The experimental data were compared with that obtained from bioreactor aerated with air and unsparged bioreactor. The results showed that the concentration of biomass is 0.36 g l-1 in sparged bioreactor with CO2/air, while, the concentration of biomass reached to 0.069 g l-1 in the unsparged bioreactor. They showed also that aerated bioreactor with CO2/air gives more biomass production even the bioreactor was aerated with air. This study proved that application of sparging system for cultivation of Chlorella vulgaris microalgae using either CO2/air mixture or air has a significant growth rate, since the biorea

... Show More
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Energy Reports
Global solar radiation prediction over North Dakota using air temperature: Development of novel hybrid intelligence model
...Show More Authors

View Publication
Scopus (78)
Crossref (79)
Scopus Clarivate Crossref