Preferred Language
Articles
/
ijcpe-1021
Electrosorption of Hexavalent Chromium Ions by MnO2/Carbon Fiber Composite Electrode: Analysis and Optimization of the Process by Box-Behnken Design
...Show More Authors

A nano manganese dioxide (MnO2) was electrodeposited galvanostatically onto a carbon fiber (CF) surface using the simple method of anodic electrodeposition. The composite electrode was characterized by field emission scanning electron microscopy (FESEM), and X-ray diffraction (XRD). Very few studies investigated the efficiency of this electrode for heavy metals removal, especially chromium. The electrosorption properties of the nano MnO2/CF electrode were examined by removing Cr(VI) ions from aqueous solutions. NaCl concentration, pH, and cell voltage were studied and optimized using the Box-Behnken design (BDD) to investigate their effects and interactions on the electrosorption process. The results showed that the optimal conditions for the removal of Cr(VI) ions were a cell voltage of 4.6 V, pH of 2 and NaCl concentration of 1.5 g/L. This work indicated that MnO2/CF electrode was highly effective in removing Cr(VI) ions and the BBD approach was a feasible and functional method for evaluating the experimental data.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 08 2019
Journal Name
International Journal Of Building Pathology And Adaptation
A scientometric analysis of BIM studies in facilities management
...Show More Authors
Purpose

The purpose of this paper is to statistically classify and categorize Building Information Modelling (BIM)-Facility Management (FM) publications in order to extract useful information related to the adoption and use of BIM in FM.

Design/methodology/approach

This study employs a quantitative approach using science mapping techniques to examine BIM-FM publications using Web of Science (WOS) database for the period between 2000 and April 2018.

Findings

The findi

... Show More
View Publication
Scopus (38)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Mon Jun 30 2025
Journal Name
Ingénierie Des Systèmes D Information
Comparative Analysis of Four Programming Languages for Machine Learning
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Al-nahrain Journal For Engineering Sciences
Performance Analysis of FSO under Turbulent Channel Using OSTBC
...Show More Authors

Free Space Optics (FSO) plays a vital role in modern wireless communications due to its advantages over fiber optics and RF techniques where a transmission of huge bandwidth and access to remote places become possible. The specific aim of this research is to analyze the Bit-Error Rate (BER) for FSO communication system when the signal is sent the over medium of turbulence channel, where the fading channel is described by the Gamma-Gamma model. The signal quality is improved by using Optical Space-Time Block- Code (OSTBC) and then the BER will be reduced. Optical 2×2 Alamouti scheme required 14 dB bit energy to noise ratio (Eb/N0) at 10-5 bit error rate (BER) which gives 3.5 dB gain as compared to no diversity scheme. Th

... Show More
View Publication
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
2018 11th International Congress On Image And Signal Processing, Biomedical Engineering And Informatics (cisp-bmei)
3D Head Shape Analysis of Suspected Zika Infected Infants
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Finite Element Analysis of Raft Foundation under Coupled Moment
...Show More Authors

Due to wind wave actions, ships impacts, high-speed vehicles and others resources of loading, structures such as high buildings rise bridge and electric transmission towers undergo significant coupled moment loads. In this study, the effect of increasing the value of coupled moment and increasing the rigidity of raft footing on the horizontal deflection by using 3-D finite element using ABAQUS program. The results showed that the increasing the coupled moment value leads to an increase in lateral deflection and increase in the rotational angle (α◦). The rotational angle increases from (0.014, 0.15 to 0.19) at coupled moment (120 kN.m), (0.29, 0.31 and 0.49) at coupled moment (240 kN.m) and (0.57, 0.63 and 1.03) at cou

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Journal Of Engineering
Analysis of Concrete Flexural Members Reinforced with Fibre Polymer
...Show More Authors

Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Deflection Analysis of an Elastic Single Link Robotic Manipulator
...Show More Authors

Abstract

Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
symmetric analysis of multiple variables classified ranked orthogonal polynomials
...Show More Authors

MCA has gained a reputation for being a very useful statistical method for determining the association between two or more categorical variables and their graphical description. For performance this method, we must calculate the singular vectors through (SVD). Which is an important primary tool that allows user to construct a low-dimensional space to describe the association between the variables categories. As an alternative procedure to use (SVD), we can use the (BMD) method, which involves using orthogonal polynomials to reflect the structure of ordered categorical responses. When the features of BMD are combined with SVD, the (HD) is formed. The aim of study is to use alternative method of (MCA) that is appropriate with order

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 28 2026
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication