Preferred Language
Articles
/
ihjtrZQBVTCNdQwCxR5D
Ag@WO3 core–shell nanocomposite for wide range photo detection
...Show More Authors

This study successfully synthesized high-performance photodetectors based on Ag-WO3 core–shell heterostructures using a simple and economical two-step pulsed laser ablation in water method and has investigated the electrical characteristics of the Ag@WO3 nanocomposite heterojunction. The Hall effect tests indicate that the synthesized Ag@WO3 exhibits n-type conduction with a Hall mobility of 1.25 × 103 cm2V-1S-1. Dark current–voltage properties indicated that the created heterojunctions displayed rectification capabilities, with the highest rectification factor of around 1.71 seen at a 5 V bias. A photodetector’s responsivity reveals the existence of two response peaks, which are situated in the ultraviolet and visible region. The photodetector demonstrates a rapid response time of less than 100 ms. The detectivity values for wavelengths of 350 nm and 490 nm were 35 × 1013 Jones and 28 × 1013 Jones, respectively. The n-Ag-WO3/n-Si photodetector achieved a maximum EQE of 11.5% in the ultraviolet wavelength when subjected to 3 V and illuminated with 350 nm (26 mW/cm2) light. The devices demonstrate rapid switching behavior with a rise time of 0.32 s and a fall time of 0.33 s. The time-dependent light response of a photodetector under illumination at 26 mW/cm2 is seen at a bias of 3 V. The light exhibits a rise and decay duration of 15 s, while the photocurrent gain is measured at 9µA. The photocurrent of devices exhibited a positive correlation with the incoming light intensity, suggesting that the junction has the potential to function as a photo detector. © The Author(s) 2024.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon May 09 2022
Journal Name
مجلة كلية التربية الاساسية الجامعة المستنصرية
Detection of sul1 resistance gene in Acinetobacter baumannii from different Clinical cases
...Show More Authors

Publication Date
Sun May 11 2014
Journal Name
World Journal Of Experimental Biosciences
Detection of hydrolytic enzymes produced by Azospirillum brasiliense isolated from root soil
...Show More Authors

Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Detection of Mineral and Microbial Contaminants in some Types of Imported Meat
...Show More Authors
Abstract<p>The main target of the current study is to investigate the microbial content and mineral contaminants of the imported meat available in the city of Baghdad and to ensure that it is free from harmful bacteria, safe and it compliances with the Iraqi standard specifications. Some trace mineral elements such as (Iron, Copper, Lead, and Cadmium) were also estimated, where 10 brands of these meats were collected. Bacteriological tests were carried out which included (total bacterial count, <italic>Staphylococcus</italic> bacteria, <italic>Salmonella</italic> bacteria). The results showed highest number of total bacterial count 13×10<sup>5</sup> CFU/g in F8 bra</p> ... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Fri Apr 30 2021
Journal Name
International Journal Of Intelligent Engineering And Systems
SMS Spam Detection Based on Fuzzy Rules and Binary Particle Swarm Optimization
...Show More Authors

View Publication
Scopus (13)
Crossref (6)
Scopus Crossref
Publication Date
Tue Sep 01 2026
Journal Name
International Journal Of Advances In Applied Sciences
COVID-19 infection detection using convolutional self-attention network with voting classifier
...Show More Authors

Early and accurate detection of COVID-19 from chest computed tomography (CT) scans are becoming essential for effective clinical decision-making and disease control. This study is proposing a robust deep learning framework that integrates a convolutional self-attention network (CSAN), gamma correction for image enhancement, and a voting-based ensemble classifier to improving diagnostic performance. The model is being evaluated on a dataset of 2,271 CT images and is achieving an accuracy of 95.12%, sensitivity of 97.25%, specificity of 98.11%, F1-score of 96.46%, and area under the curve (AUC) of 0.977. Experimental results are demonstrating that the proposed method significantly surpasses baseline models, including standalone CSAN,

... Show More
View Publication
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
Fast Shot Boundary Detection Based on Separable Moments and Support Vector Machine
...Show More Authors

View Publication
Scopus (33)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Mon Apr 19 2010
Journal Name
Computer And Information Science
Quantitative Detection of Left Ventricular Wall Motion Abnormality by Two-Dimensional Echocardiography
...Show More Authors

Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Detection of Nutrients and Major Ions at Al Muthanna Storage Site Soil
...Show More Authors

In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesi

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Feb 03 2016
Journal Name
Nanoscience And Nanotechnology
Fabrication of Functionalize Reduce Graphene Oxide and Its Application in Ampicillin Detection
...Show More Authors

Graphene oxide (GO) was prepared from graphite (GT) with Hammer method, the GO was reduced with hydrazine hydrate to produce a reduced graphene oxide (RGO). The RGO was reacted with thiocarbohydrazide (TCH) to functionalize the RGO with 4-amino-3-symbol-1h-1, 2, 4-triazol-5 (4H) –thion group and to obtain (RGOT). All the prepared nanomaterial and the product of the functionalization RGOT were characterized with Fourier transformer infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) analysis. RGOT mixed with ultrasonic device at different pH values of phosphate buffer solution (PBS), the mixture used to modifying a screen printed carbon electrodes SPCE and with cyclic voltammetry the sensitivity of selectivity of the new modifying elect

... Show More
Preview PDF